Evaluating the Level of Agreement Between AAMI/ESH/ISO Universal Standard Requirements and the HUAWEI D2 Watch-Type Wrist Blood Pressure Monitor

An Observational Cross-Sectional Blind Comparison to Evaluate the Level of Agreement Between AAMI/ESH/ISO Universal Standard Requirements and the HUAWEI D2 Watch-Type Wrist Blood Pressure Monitor

Status
Recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT07297277
Enrollment
85
Registered
2025-12-22
Start date
2025-07-15
Completion date
2027-10-31
Last updated
2025-12-30

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Blood Pressure Monitoring

Keywords

Blood Pressure, Auscultatory, Oscillometric, Watch Type Monitor, Validation

Brief summary

Getting an accurate blood pressure (BP) reading is essential for diagnosing high blood pressure and managing it effectively. High blood pressure is a major health problem, causing about 9.4 million deaths worldwide each year. More people need to monitor their BP at home, so there is greater demand for easy-to-use devices. Traditional BP monitors with arm cuffs can be bulky, uncomfortable, and awkward to use. Modern technology has made it possible to measure BP using wearable devices like smartwatches. HUAWEI has developed a wrist watch that can measure BP and has been tested to meet international standards. The watch passed these tests and was approved for people to use at home to check their own BP. However, the HUAWEI watch was only tested on people in China and the investigators need to know if it works for people from other countries and ethnic backgrounds.

Detailed description

Accurate measurement of blood pressure (BP) is a necessity for the reliable diagnosis and proficient management of hypertension. However, validation of blood pressure monitoring devices only began in the 1980's, followed by a series of ad-hoc validation protocols from differing organisations such as the Advancement of Medical Instrumentation (AAMI), the British Hypertension Society (BHS), the German Hypertension League, the European Society of Hypertension (ESH), and the International Organisation for Standardization (ISO) over the subsequent three decades. The need for a universally acceptable protocol was recognised and members of the AAMI, ESH, and ISO committees collaborated to re-examine the aspects of validation to achieve a consensus on an optimal validation standard. With an increased prevalence of hypertension, causing approximately 9.4 million deaths per year worldwide, the demand for non-invasive arterial pressure monitoring devices has also increased to help patients manage blood pressure (BP). Traditionally, non-invasive BP measurement techniques include auscultatory and oscillometric devices, however, these can present with several limitations in terms of cuff size, instruments' bulky volume, and discomfort caused by external pressure. Advancements in technology has meant that wearable devices are becoming readily available for various health related measurements, including BP. The HUAWEI Technology have developed an automated oscillometric wearable wrist watch-type device for BP measurement that has recently been validated in accordance with the AAMI/ESH/ISO Universal Standard requirements and can be recommended for self-measurement. However, while this research concluded the HUAWEI watch fulfilled the requirements for self-measurement in the general population, it should be noted that the study was conducted within the Chinese population only. Consequently, to ensure generalisation to a wider population, it is important to examine the HUAWEI watch validity within differing populations. Therefore, the aim of this study will be to explore if the HUAWEI D2 watch-type blood pressure monitor meets the AAMI/ESH/ISO Universal Standard requirements in differing populations.

Interventions

None listed

Sponsors

Northumbria University
Lead SponsorOTHER

Study design

Observational model
OTHER
Time perspective
CROSS_SECTIONAL

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Age \>18 years * Written informed consent provided

Exclusion criteria

* Cardiac Arrythmias * Peripheral Arterial Disease * Known Heart Disease * Pregnancy * Diagnosis of Secondary Hypertension

Design outcomes

Primary

MeasureTime frameDescription
Level of Agreement Between Auscultatory and HUAWEI D2 Watch Blood Pressure Measurements.BaselineThe level of agreement between auscultatory systolic blood pressure (mmHg) and diastolic blood pressure (mmHg), and the HUAWEI D2 watch systolic blood pressure (mmHg) and diastolic blood pressure (mmHg) measurements will be determined using the AAMI/ESH/ISO standard requirements for blood pressure device validation.

Countries

United Kingdom

Contacts

Primary ContactHelen Llewellyn, MSc
helen.llewellyn@northumbria.ac.uk+447949026070
Backup ContactGabriel Cucato, PhD
gabriel.cucato@northumbria.ac.uk

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026