Improving Visual Quality in Patients With Irregular Corneas Using Asymmetrical Toric Intraocular Lenses

VITAL - "Visual Improvement With Toric Asymmetrical Lenses": Enhancing Vision in Irregular Corneas

Status
Recruiting
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT07294716
Acronym
VITAL
Enrollment
15
Registered
2025-12-19
Start date
2026-01-20
Completion date
2027-06-01
Last updated
2026-01-26

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Astigmatism, Cataract and IOL Surgery, Irregular Astigmatism

Brief summary

Cataract surgery in patients with irregular corneas presents unique challenges, primarily due to the high variability in keratometry and corneal tomography measurements, which complicates accurate intraocular lens (IOL) calculations. In these patients, therapeutic options are currently limited to either non-toric IOLs and rigid contact lenses postoperatively or conventional toric IOLs for the reduction of total astigmatism within cataract surgery. While conventional toric IOLs may be beneficial in selected cases with a stable astigmatic pattern and clear axis, their effectiveness is largely limited, as significant irregularity and higher order aberrations reduce predictability, accuracy of formulae, and refractive outcomes. Therefore, the development of a reliable method to reduce total astigmatism - including irregular components - would represent a major advancement, potentially improving both visual function and patient quality of life. The aim of this exploratory study is to evaluate the effectiveness of customized toric intraocular lenses (AMILens Individual, AMIPLANT GmbH, Germany) in reducing total corneal astigmatism in patients with a significant irregular astigmatic component. These lenses are designed to address corneal aberrations up to the 6th Zernike order, thereby extending correction beyond the capabilities of conventional toric IOLs. To our knowledge, no clinical study has yet investigated this novel approach.

Interventions

DEVICEAMILens Individual

An acrylic hydrophilic, one piece 4-loop haptic, monofocal, toric IOL (AMILens Individual, AMIPLANT GmbH, Germany) will be implanted into the capsular bag after removal of the of the natural lens. This IOL is CE-certified. Asphericity and dioptric power of the IOL are customized for each individual eye.

Sponsors

Johannes Kepler University of Linz
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
21 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Age 21 years or older * Scheduled cataract surgery * At least 1.75 D of total astigmatism in the CASIA2 measurement * At least 0.75 D of asymmetry or higher order irregularity within the 6mm zone of the real (total) index corneal refractive map of the CASIA2 measurements

Exclusion criteria

* Relevant central corneal scars * PEX, previous ocular surgery, severe trauma or any pathology that could lead to an unstable capsular bag * Combined surgery (cataract plus glaucoma/vitreoretinal/corneal surgery) * Postoperative best corrected distance visual acuity below 0.3 Snellen decimal * Pregnancy

Design outcomes

Primary

MeasureTime frameDescription
Change of Astigmatism4-8 weeks post-surgeryThe change of astigmatism is defined by the difference of the postoperative total refractive/ocular astigmatism (assessed via subjective refraction) to the preoperative corneal astigmatism (assessed via the utilized measurement devices). Reduction in total ocular (refractive) astigmatism will be quantified as both absolute reduction (Diopter) and relative reduction (%). Descriptive statistics will include mean, standard deviation, median, interquartile range, and range. Normality will be tested using the Shapiro-Wilk test and Q-Q plots. If normally distributed: comparisons between preoperative and postoperative values will be assessed with a paired t-test. If not normally distributed: the Wilcoxon signed-rank test will be applied. Results will be presented with 95% confidence intervals. As this is an exploratory study, p-values will be reported descriptively, and values below 0.05 will not be interpreted as statistically significant.

Secondary

MeasureTime frameDescription
Agreement of measured variables for astigmatism across devices4-8 weeks post cataract surgeryThe agreement of the variables anterior corneal astigmatism, posterior corneal astigmatism, total corneal astigmatism, Zernike Polynomials first to seventh order, lower order aberrations (LOAs), and higher order aberrations (HOAs) are compared across the utilized measurement devices Pentacam, Anterion, ms39, and CASIA2. All mentioned variables are on a ratio scale. Agreement between different devices will be assessed using: Bland-Altman analysis (mean difference and 95% limits of agreement),Intraclass correlation coefficients (ICCs) for reliability, and, where appropriate, repeated-measures ANOVA or Friedman test (non-parametric) across multiple modalities.
Change of higher order optical aberrations (HOAs)4-8 weeks post cataract surgeryHigher order optical abberation values are measured posoperatively for the whole eye (cornea and lens) with the osiris device, and compared to the preoperative corneal higher order abberations, which are measured with the Casia2 and the ms39 devices. Reduction in higher order aberrations will be quantified as both absolute reduction (D) and relative reduction (%). The same descriptive statistics, normality testing, and comparison testing as described above will be applied. Results will be presented with 95% confidence intervals and p-values will be reported descriptively.
Surgically induced corneal astigmatism (SIA)From enrollment to the end last study visit (4-8 weeks post surgery)Surgically induced corneal astigmatism (SIA) will be evaluated by calculating the vectorial changes of corneal astigmatism (magnitude ind diopter and axis in degree) between preoperative and postoperative corneal astigmatism measurements for each measurement device
Postoperative uncorrected and best-corrected distance visual acuity4-8 weeks post cataract surgeryThese values are assessed via standardized subjective refraction using the jackson cross cylinder method, and will be described descriptively in logMAR unit. Postoperative uncorrected and best-corrected visual acuity will be analyzed as both continuous variables and using threshold-based categories. Descriptive statistics will include mean, standard deviation, median, interquartile range, and range.