Skip to content

Safety and Efficacy of the 3DMax™ MID Anatomical Mesh (BD, USA) in Laparoscopic-endoscopic Inguinal Hernia Repair - Multicenter, Prospective Observational Study

Safety and Efficacy of the 3DMax MID Anatomical Mesh (BD, USA) in Laparoendoscopic Inguinal Hernia Repair: A Multicenter Prospective Observational Cohort Study

Status
Not yet recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT07289802
Acronym
3DMS
Enrollment
300
Registered
2025-12-17
Start date
2026-01-01
Completion date
2027-04-01
Last updated
2025-12-17

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hernia, Inguinal

Keywords

Hernia, Mesh, Inguinal Hernia, Recurrence

Brief summary

This is a multicenter, prospective, observational cohort study evaluating the safety and efficacy of the 3DMax MID Anatomical Mesh (BD, USA) in laparoendoscopic inguinal hernia repair. Adult patients undergoing elective transabdominal preperitoneal (TAPP) or totally extraperitoneal (TEP) repair will be enrolled and followed according to routine clinical practice. The primary objective is to assess the inguinal hernia recurrence rate within 12 months after surgery. Secondary objectives include evaluation of postoperative pain, groin discomfort and foreign body sensation, as well as early and late postoperative complications. All participating patients will receive the 3DMax MID Anatomical Mesh as part of standard care. No additional experimental procedures are planned. Clinical data will be collected at baseline and during predefined follow-up contacts (early postoperative period, 1 month, 3 months and 12 months) using standardized forms and patient interviews.

Detailed description

Laparoendoscopic techniques such as transabdominal preperitoneal (TAPP) and totally extraperitoneal (TEP) repair are widely used for the treatment of inguinal hernia and are associated with faster recovery and lower rates of chronic pain compared with open repair in appropriately selected patients. Mesh reinforcement is a key component of these procedures. Three-dimensional, anatomically contoured meshes have been developed to improve conformability to the myopectineal orifice and to provide stable coverage of the inguinal region, potentially reducing the need for additional fixation and lowering the risk of chronic postoperative pain. The 3DMax MID Anatomical Mesh (BD, USA) is a medium-weight, macroporous, pre-shaped polypropylene mesh designed specifically for inguinal hernia repair. Its three-dimensional configuration and recoil properties are intended to facilitate correct positioning and stable coverage of the inguinal anatomy during laparoendoscopic procedures. This multicenter, prospective, observational cohort study will include consecutive adult patients undergoing elective TAPP or TEP inguinal hernia repair in participating centers, in whom the operating surgeon has decided to use the 3DMax MID Anatomical Mesh as part of routine practice. No randomization or control group is planned, and no interventions outside standard care will be performed. Data will be collected from medical records and structured follow-up contacts (early postoperative check, approximately 30 days, 3 months and 12 months after surgery). The primary endpoint is hernia recurrence within 12 months. Secondary endpoints include postoperative pain, groin discomfort, foreign body sensation and early or late postoperative complications. Study data will be recorded in a standardized database and analyzed descriptively to characterize the safety profile and clinical performance of the 3DMax MID Anatomical Mesh in real-world practice.

Interventions

DEVICE3DMax MID Anatomical Mesh

Implantation of a pre-shaped, medium-weight, macroporous polypropylene anatomical mesh (3DMax MID Anatomical Mesh, BD, USA) during elective laparoendoscopic inguinal hernia repair (TAPP or TEP) as part of routine clinical practice. No additional experimental procedures beyond standard surgical care are planned.

Sponsors

Swissmed Hospital
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Age 18 years or older * Primary unilateral or bilateral inguinal hernia * Scheduled for elective laparoendoscopic inguinal hernia repair (TAPP or TEP) * Considered suitable for general anesthesia and laparoendoscopic approach by the treating surgeon * 3DMax MID Anatomical Mesh planned for use as part of routine clinical care * Ability and willingness to provide written informed consent

Exclusion criteria

* Age below 18 years * Emergency surgery (e.g. incarcerated or strangulated hernia requiring urgent intervention) * Contaminated or potentially contaminated surgical field * Recurrent inguinal hernia in the same groin (previous repair with mesh or suture) * Concomitant procedures or clinical situations in which the surgeon decides that a different mesh concept or technique is required * Inability or unwillingness to comply with follow-up schedule (e.g. lack of telephone contact, severe cognitive impairment)

Design outcomes

Primary

MeasureTime frameDescription
Inguinal hernia recurrence rate at 12 months12 months after index surgeryProportion of patients with clinically and/or imaging-confirmed inguinal hernia recurrence within 12 months after the index laparoendoscopic repair with 3DMax MID Anatomical Mesh.

Secondary

MeasureTime frameDescription
Postoperative pain intensity (VAS 0-10)7-10 days, 30 days, 3 months and 12 months after surgeryPostoperative pain intensity assessed using a 0-10 Visual Analog Scale (VAS) during early and late follow-up. Chronic pain will be defined as VAS ≥4 persisting beyond 3 months after surgery.
Early postoperative complications (≤30 days)Up to 30 days after surgeryIncidence of early postoperative complications within 30 days after surgery, including wound infection, hematoma, seroma, urinary retention, bleeding, and other mesh- or procedure-related adverse events.
Late postoperative complications (>30 days to 12 months)From >30 days to 12 months after surgeryIncidence of late postoperative complications occurring between 30 days and 6 months after surgery, including chronic groin pain, mesh-related complications, and reoperations in the operated groin.
Groin discomfort and foreign body sensation7-10 days, 30 days, 3 months and 12 months after surgeryPatient-reported groin discomfort, stiffness and foreign body sensation in the operated region, assessed using standardized questions or Likert-type scales during follow-up contacts.

Contacts

Primary ContactMateusz Zamkowski, MD, PhD
zamek@gumed.edu.pl22 543 33 60

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026