Skip to content

Clinical Investigation of IXIUM TWIN Viscoelastic Ophthalmic Device For Cataract Surgery

Randomized Clinical Investigation Of The IXIUM TWIN Viscoelastic Ophthalmic Device (OVD) For Cataract Surgery With Intraocular Lens Implantation

Status
Not yet recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT07279506
Acronym
IXIUM_TWIN
Enrollment
180
Registered
2025-12-12
Start date
2026-01-31
Completion date
2026-09-30
Last updated
2025-12-12

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cataract Surgery

Brief summary

This clinical trial is testing a new surgical gel called IXIUM TWIN, designed to protect the eye during cataract surgery. Cataracts, which cloud the eye's natural lens, are the leading cause of vision loss worldwide. Surgery to remove the cataract and replace it with an artificial lens is the standard treatment, and viscoelastic gels like IXIUM TWIN are used to keep the eye stable and safe during the procedure. The goal of this study is to compare IXIUM TWIN with an already approved gel (HEALON) to ensure it works just as well (or better) in protecting the delicate cells inside the eye. Specifically, researchers will measure whether IXIUM TWIN causes less damage to the eye's inner lining (endothelial cells) after surgery. Who can take part? Adults aged 18 and older who have cataracts and are scheduled for surgery may qualify. Only one eye per participant will be included. Patients must be able to attend follow-up visits and provide informed consent. What does participation involve? Before surgery, participants will have eye exams to check vision, cell health, corneal thickness, and eye pressure. During surgery, they will randomly receive either IXIUM TWIN or HEALON (neither the patient nor the surgeon will choose). After surgery, follow-up visits at 1 day, 7 days, 30 days, and 90 days will monitor healing, vision improvement, and any side effects. Potential risks and benefits As with any cataract surgery, there are minor risks, such as temporary increased eye pressure, inflammation, or swelling, but these are rare and usually resolve quickly. The benefits include improved vision after cataract removal. If successful, IXIUM TWIN could offer surgeons another high-quality option for protecting the eye during surgery. Study timeline Patient enrollment begins in January 2025 and ends in June 2025, with follow-ups completing by September 2025. The full study is expected to conclude in early 2026. This study is sponsored by LCA Pharmaceutical and will take place at four hospitals in France. Participation is voluntary, and patients can withdraw at any time.

Interventions

DEVICEIXIUM TWIN

Use of IXIUM TWIN as the Ophthalmic Viscosurgical Devices in the cataract surgery

DEVICEHEALON

Use of HEALON as the Ophthalmic Viscosurgical Devices in the cataract surgery

Sponsors

LCA Pharmaceutical
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
SUPPORTIVE_CARE
Masking
DOUBLE (Subject, Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Adult patients (≥18 years) with cataract (described and coded per WHO classification²⁷) * One eye per patient enrolled in the clinical investigation (IC) * Intraocular pressure (IOP) controlled or uncontrolled with treatment * Cataract extraction via phacoemulsification with implantation of a posterior chamber injectable intraocular lens (IOL) through a small incision * Signed informed consent from both patient and physician * Patient capable of understanding the IC procedures and geographically stable * Patient covered by or eligible for a social security/health insurance system

Exclusion criteria

* Patient unable to participate in a clinical investigation (IC) * Pregnant women or those at risk of pregnancy during the study * Patient under legal guardianship (tutelle), conservatorship (curatelle), or judicial protection (sauvegarde de justice) * Patient currently enrolled in another clinical investigation at the time of inclusion

Design outcomes

Primary

MeasureTime frameDescription
Percentage of Endothelial Cell Loss between pre- and post-operative periods90 daysThe primary outcome measure is the percentage of endothelial cell loss observed between the pre-operative and post-operative periods during cataract surgery using viscoelastic devices (OVDs). The study assumes that the percentage of endothelial cell loss after using IXIUM TWIN is not clinically worse than that seen with the comparator HEALON, with a non-inferiority margin set at -15%.

Secondary

MeasureTime frameDescription
Slit-lamp biomicroscopy90 daysSlit-lamp biomicroscopy at each visit: Multicriteria evaluation graded (1+ to 4+) per the Standardization of Uveitis Nomenclature (SUN) Working Group classification: * Corneal edema: Mild (grade 1+), moderate (grade 2+), severe (grade 3+) * Corneal opacity (% surface area): ≤25% (grade 1+), 26-50% (grade 2+), ≥51% (grade 3+) * Iritis syndrome: Iris involvement only (grade 1+), iridocyclitis (grade 2+), diffuse anterior chamber (AC) involvement (grade 3+) * Inflammatory cells in 1×1 mm field: 6-15 (grade 1+), 16-25 (grade 2+), 26-50 (grade 3+), \>50 (grade 4+) * Anterior chamber flare: Mild (grade 1+), clear details (grade 2+), hazy details (grade 3+), intense with fibrin (grade 4+)
Pachymetry90 daysMeasurement of corneal thickness
Best-corrected visual acuity (BCVA) for distance and near vision90 daysBest-corrected visual acuity (BCVA) for distance and near vision at Day 7, 30, and 90 (uncorrected at Day 1).
Proportion of patients with intraocular pressure (IOP) ≥30 mmHg90 daysProportion of patients with intraocular pressure (IOP) ≥30 mmHg at each visit.
Patient satisfaction assessment regarding the procedure (Likert scale)90 daysPatient satisfaction assessment regarding the procedure (Likert scale). Very satisfying - Satisfying - Acceptable - Insufficient
Assessment of adverse events90 daysAssessment of adverse events at all visits
Assessment of the viscoelastic device (DM) behaviorPost-opAssessment of the viscoelastic device (DM) behavior at each surgical step, distinguishing between the two phases: dispersive and cohesive (Likert scale).

Contacts

Primary ContactPatrice VINCENT
pvincent@lca-pharma.com02 37 33 39 30

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026