Skip to content

Real-world Study on Fenestrated Stent for Thoracic Aortic Dissection

Multi-center, Real-world Study on the Treatment of Thoracic Aortic Dissection With a Straight-type Fenestrated Covered Stent System for Thoracic Aortic Aneurysms

Status
Active, not recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT07268755
Enrollment
320
Registered
2025-12-08
Start date
2024-12-01
Completion date
2027-11-30
Last updated
2025-12-08

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Thoracic Aortic Disease, Thoracic Aortic Dissection

Keywords

thoracic aortic dissection, Talos, Perforated Stent-Graft

Brief summary

Study Title: Multi-center Real-world Study on Straight Tubular Thoracic Aortic Perforated Stent-Graft System for Treating Thoracic Aortic Dissection Purpose: This study aims to evaluate the effectiveness of the Talos stent-graft system, a new device designed to treat aortic dissection (a life-threatening condition where the inner layer of the aorta tears). The stent has unique features like perforations and tapered design to reduce complications compared to traditional stents. Key Features of the Talos Stent: Longer length to cover more of the damaged aorta Perforated design at the distal end to improve blood flow Tapered shape to better match natural aortic anatomy Potentially reduces risks like new tears or spinal cord ischemia Study Details: Type: Real-world study (combining prospective and retrospective data) Duration: 3 years (2024-2027) Participants: 320 patients across 5 major hospitals in Shanghai Follow-up: Regular check-ups at 1, 3, 6, 12, and 24 months post-surgery Who Can Participate? Patients may qualify if they: Are ≥18 years old Have aortic dissection requiring treatment Have suitable blood vessels for stent placement Can commit to follow-up visits Who Cannot Participate? Patients with: Connective tissue disorders (e.g., Marfan syndrome) Active infections or cancer with limited life expectancy Severe allergies to stent materials/contrast dye Pregnancy or planning pregnancy What Does Participation Involve? Pre-Surgery: Physical exams, blood tests, CT scans Surgery: Minimally invasive stent placement via groin artery Post-Surgery: Blood pressure management, antiplatelet medication (e.g., aspirin) Follow-up: CT scans and quality-of-life questionnaires Potential Benefits: Improved aortic healing Reduced need for repeat surgeries Better quality of life (measured by VascuQoL questionnaire) Possible Risks: Standard stent risks (bleeding, infection, allergic reactions) Device-related complications (leaks, migration, new tears) Organ ischemia (reduced blood flow to kidneys/other organs) Safety Monitoring: Independent review of all CT scans 24/7 access to vascular specialists Immediate reporting of any complications Ethical Protections: Approved by ethics committees at all hospitals Voluntary participation with signed consent Right to withdraw anytime without affecting care For Healthcare Providers: This investigator-initiated study (IIS) is funded by Shanghai Science & Technology Commission. It uses standardized protocols across centers with electronic data capture (EDC) for consistency. The primary endpoint is 12-month treatment success (defined as technical success + no reintervention). Secondary endpoints include aortic remodeling rates and complication profiles. Contact Information: Principal Investigator: Dr. Meng Qingyou Institution: Shanghai General Hospital Phone: +86-133-0621-1019

Interventions

DEVICETALOS

A Real-World Study on the Effectiveness of the Talos Thoracic Stent Graft System in Thoracic Endovascular Aortic Repair for Aortic Dissection.

Sponsors

Qingyou Meng
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
OTHER

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Patients scheduled for or already receiving the Talos stent; 2. Age ≥18 years, any gender, non-pregnant or non-lactating; 3. Diagnosed with aortic dissection; 4. Presence of a ≥15mm effective proximal landing zone; 5. Having eligible access artery anatomy; 6. Expected survival \>1 year; 7. Capable of understanding the trial purpose, voluntarily participating, signing informed consent, and willing to undergo follow-up.

Exclusion criteria

1. Definitive diagnosis of aortic-related connective tissue disorders (e.g., Marfan syndrome); 2. Subjects with infectious aortic dissection; 3. Documented allergy to nitinol alloys, contrast agents, or related materials; 4. Severe hepatic/renal dysfunction (ALT or AST \>2.5×ULN, serum creatinine \>2×ULN); 5. Uncontrolled severe infections (e.g., bacteremia or septicemia); 6. History of active bleeding, coagulopathy, or refusal of blood transfusion; 7. Malignancy with life expectancy \<1 year; 8. Pregnancy, lactation, or planned pregnancy during the trial; 9. Concurrent participation in other drug/device trials without completing primary endpoints; 10. Poor compliance with anticipated inability to complete follow-up; 11. Other investigator-determined contraindications for endovascular therapy (e.g., unsuitable vascular access, non-cooperation).

Design outcomes

Primary

MeasureTime frameDescription
Treatment success rate at 12 months post-procedure12 monthsDefined as immediate technical success after the procedure and no reintervention required during the 12-month follow-up period.
Treatment success rate at 12 months post-procedure, defined as immediate technical success after the procedure and no reintervention required during the 12-month follow-up period.12 months

Countries

China

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026