Skip to content

Can Cocoa Flavanols Protect Endothelial Function During Prolonged Sitting in Healthy Older Adults?

A Placebo-controlled, Randomized, Double-masked, Cross-over Acute Intervention Study Investigating the Effects of Cocoa Flavanols on Peripheral Endothelial Function in the Context of Prolonged Sitting in Healthy Older Adults

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT07265869
Enrollment
20
Registered
2025-12-05
Start date
2022-08-02
Completion date
2023-08-24
Last updated
2025-12-05

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Ageing, Healthy

Keywords

vascular function, endothelial function, flow-mediated dilatation, flavanols, cocoa, flavonoids, polyphenols, sitting, sedentary, ageing, older adults, functional Near-Infrared Spectroscopy

Brief summary

Sitting time is high in older adults and has been shown to temporarily impair endothelial function and blood pressure. Flavanols, plant-derived compounds, acutely enhance endothelial function and reduce Blood pressure in older adults. The aim of this study is to investigate whether acute ingestion of cocoa flavanols can improve peripheral endothelial function and blood pressure during prolonged sitting in healthy older adults. In a randomised, double-blinded, cross-over, placebo-controlled human study, 20 healthy older adults will consume either a high-flavanol (695 mg) or low-flavanol (5.6 mg) cocoa beverage immediately before a 2-hour sitting bout. Flow-mediated dilation (FMD) of the superficial femoral (SFA; primary outcome) and brachial (BA) arteries, and blood pressure, were assessed before and after sitting. Microvasculature haemodynamics were assessed in the gastrocnemius before, during, and after sitting. It is hypothesized that the high flavanol cocoa will prevent declines in brachial and superficial femoral Flow-mediated dilatation post sitting.

Detailed description

Older individuals are estimated to spend more than 10 hours in their waking day in sedentary activities , which can include sitting bouts lasting up to 5.4 hours/day . Greater sedentary time was found to be associated with a significantly increased risk of cardiovascular diseases and all-cause mortality. Several experimental studies have shown that even just one isolated episode of prolonged sitting (from 1 to 6 hours) has detrimental effects on human endothelial function, as measured by flow-mediated dilation (FMD). Flavonoid-rich foods are typically consumed in high amounts in cardioprotective diets, with evidence from both observational and Randomised Controlled Trials showing flavonoids to improve biomarkers of cardiovascular health. Flavanols, a sub-group of flavonoids present in unprocessed cocoa, have been extensively shown to act quickly within the vasculature, improving both brachial Flow-mediated dilatation and lower-limb common femoral artery (CFA) Flow-mediated dilatation within 2 hours of intake in older adults. The aim of the current study is to examine whether acute consumption of cocoa flavanols prior to a 2-hour bout of uninterrupted sitting can be beneficial in improving endothelial function (as measured by Flow mediated dilatation) in the upper-limb Brachial Artery (BA) and lower-limb Superficial Femoral Artery (SFA) in older adults, as well as downstream, muscle microvascular function. We will further investigate whether cocoa flavanols can prevent sitting-induced increases in blood pressure in older adults. We hypothesise that cocoa flavanols would be effective at rescuing upper- and lower-limb Flow-mediated dilatation and improve blood pressure during uninterrupted sitting in older age

Interventions

DIETARY_SUPPLEMENTHigh-flavanol cocoa powder

12 g of a fat-reduced natural cocoa powder containing 150 mg of (-)-epicatechin, and 695 mg of total flavanols

DIETARY_SUPPLEMENTLow-flavanol cocoa powder

12 g of a fat-reduced alkalized cocoa powder containing 5.6 mg of total flavanols

Sponsors

University of Birmingham
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
PREVENTION
Masking
TRIPLE (Subject, Investigator, Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Age
65 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Males and females * aged 65 or more

Exclusion criteria

* history or symptoms of cardiovascular, renal, pulmonary, metabolic, or neurologic disease, hypertension (blood pressure higher than 140/90 mm Hg, based on recent guidelines), diabetes mellitus, anaemia, asthma, immune conditions, or high cholesterol. * smoker * individuals who were on weight-reducing diets * individuals taking anticoagulants, * had recently undergone prolonged bed-rest periods * have been on antibiotics in the previous 3 months * have an infection at present (e.g. cold) or viral infection

Design outcomes

Primary

MeasureTime frameDescription
Flow-mediated dilatation of the superficial femoral arteryChange from pre-intervention baseline to 2 hours post intervention /2 hours post sittingFlow-mediated dilatation (FMD) of the superficial femoral artery. Expressed as percent FMD: change in brachial diameter from baseline to peak dilation following 5 minutes of arterial occlusion. Brachial artery diameter and blood flow will be measured using Doppler ultrasonography (uSmart 3300, Terason).

Secondary

MeasureTime frameDescription
Tissue oxygenation index (TOI) of Gastrocnemius skeletal muscleChange from pre-intervention baseline to 2 hours post-intervention / 2 hours of sittingTissue Oxygenation Index (percent TOI) will be assessed by functional Near-Infrared Spectroscopy (fNIRS) on the medial head of the gastrocnemius muscle during 5 min of superficial femoral arterial occlusion and 5 min of post-occlusion (reactive hyperaemia). The NIRS device measures changes in chromophore concentrations of oxyhaemoglobin (O2Hb) and deoxyhaemoglobin (HHb), providing depth-resolved measures of total tissue oxygen saturation.
Normalized haemoglobin index (nTHI) of the gastrocnemius skeletal muscleChange from pre-intervention baseline to 2 hours post-intervention/2 hours sittingNormalized haemoglobin index (relative value of total haemoglobin normalised to the initial value, nTHI) content (a.u.) will be assessed by functional Near-Infrared Spectroscopy (fNIRS) on the medial head of the gastrocnemius muscle during 5 minutes of superficial femoral arterial occlusion and 5 minutes of post-occlusion (reactive hyperaemia).
Tissue oxygenation index (TOI) of Gastrocnemius skeletal muscle during 2 hours of sittingPost-intervention time points considered during sitting were 0 , 10 , 60 and 120 minutes.Tissue Oxygenation Index (percent TOI) will be assessed by functional Near-Infrared Spectroscopy (fNIRS) on the medial head of the gastrocnemius muscle continuously during 2 hours of sitting. The NIRS device measures changes in chromophore concentrations of oxyhaemoglobin (O2Hb) and deoxyhaemoglobin (HHb), providing depth-resolved measures of total tissue oxygen saturation. Post-intervention time points considered during sitting were 0 minutes , 10 minutes, 60 minutes, and 120 minutes. For each time point, data were averaged over a 60-second period.
Normalized haemoglobin index (nTHI) of Gastrocnemius skeletal muscle during 2 hours of sittingPost-intervention time points considered during sitting were 0 min , 10 min, 60 min and 120 min.Normalized haemoglobin index (relative value of total haemoglobin normalised to the initial value, nTHI) content (a.u.) will be assessed by functional Near-Infrared Spectroscopy (fNIRS) on the medial head of the gastrocnemius muscle continuously during 2 hours of sitting. Post-intervention time points considered during sitting were 0 min , 10 min, 60 min, and 120 min. For each time point, data were averaged over a 60-second period.
Brachial Systolic Blood Pressure (SBP)Change from pre-intervention baseline to 2 hours post-intervention / 2 hours of sittingResting systolic blood pressure (mmHg) will be measured using an automated oscillometric blood pressure monitor, with a cuff attached to the right upper arm, following at least 10 minutes rest.
Flow-mediated dilatation of the brachial arteryChange from pre-intervention baseline to 2 hours post-intervention/ 2hours post sittingFlow-mediated dilatation (FMD) of the brachial artery. Expressed as percent FMD: change in brachial diameter from baseline to peak dilation following 5 minutes of arterial occlusion. Brachial artery diameter and blood flow will be measured using Doppler ultrasonography (uSmart 3300, Terason).
Heart RateChange from pre-intervention baseline to 2 hours post-intervention/2 hours sittingResting Heart Rate (beats per minute) will be measured using an automated oscillometric blood pressure monitor, with a cuff attached to the right upper arm, following at least 10 minutes rest.
Resting Superficial Femoral Artery Blood FlowChange from pre-intervention baseline to 2 hours post-intervention/2 hours sittingSuperficial Femoral Artery Blood Flow velocity (ml min-1) will be measured using Doppler ultrasonography (uSmart 3300, Terason) interfaced with the Quipu analysis software. Superficial femoral artery blood flow is calculated using Superficial femoral artery blood velocity and diameter during 1 minute of recording in a resting state
Resting Brachial Artery Blood FlowChange from pre-intervention baseline to 2 hours post-intervention/2 hours sittingResting Brachial Artery Blood Flow velocity (ml min-1) will be measured using Doppler ultrasonography (uSmart 3300, Terason) interfaced with the Quipu analysis software. Brachial Artery blood flow is calculated using brachial artery blood velocity and diameter during1 minute of recording in a resting state
Superficial Femoral Artery Shear RateChange from pre-intervention baseline to 2 hours post-intervention/2 hours sittingSuperficial Femoral Artery Shear Rate shear rate (s-1) will be measured using Doppler ultrasonography (uSmart 3300, Terason) interfaced with the Quipu analysis software, during 1 minute in the resting state
Brachial Artery Shear RateChange from pre-intervention baseline to 2 hours post-intervention/2 hours sittingBrachial Artery Shear Rate shear rate (s-1) will be measured using Doppler ultrasonography (uSmart 3300, Terason) interfaced with the Quipu analysis software, during 1 minute in the resting state
Brachial Diastolic Blood Pressure (DBP)Change from pre-intervention baseline to 2 hours post-intervention / 2 hours of sittingResting diastolic blood pressure (mmHg) will be measured using an automated oscillometric blood pressure monitor, with a cuff attached to the right upper arm, following at least 10 minutes rest.

Countries

United Kingdom

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026