Skip to content

The LUCENT Study - LUng Lesion Assessment Via BF-UCP190F for Central and Extended Nodal Targeting

The LUCENT Study - LUng Lesion Assessment Via BF-UCP190F for Central and Extended Nodal Targeting

Status
Not yet recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT07253727
Acronym
LUCENT
Enrollment
200
Registered
2025-11-28
Start date
2025-12-01
Completion date
2028-08-31
Last updated
2025-11-28

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Bronchoscopy

Brief summary

The Olympus BF-UCP190F bronchoscope combines the reach of a thinner bronchoscope with the benefit of real-time ultrasound, enabling direct lesion visualization and sampling deeper into the lung. Following promising first-in-human data, the LUCENT study aims to evaluate the utility feasibility, effectiveness and safety of this device in a multicenter setting, generating real-world evidence to inform broader adoption in global markets.

Interventions

OTHERNo Interventions

no intervention, only observational

Sponsors

Heidelberg University
CollaboratorOTHER
Lung Clinic Hemer
CollaboratorOTHER
Olympus Europe SE & Co. KG
Lead SponsorINDUSTRY

Study design

Observational model
OTHER
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Willing and able to provide informed consent. 2. ≥18 years of age. 3. The target lesion(s) must be located within the inner and middle two-thirds of the lung, as determined prospectively using the Software-Assisted Method (SAM). To ensure accurate localization, SAM applies anatomical measurements to classify lesions as inner, middle, or outer third of the lung. The lesion must contact the border of the inner two-thirds region; lesions fully outside this region will be excluded from the study cohort. In addition, the lesion must be located at least two airway generations distal to the main carina, as confirmed radiographically by the bronchoscopist 4. Target lesion: nodule ≥ 10mm or lymph node ≥ 5mm. 5. Target lesion location documented on CT or PET report. 6. Indicated for bronchoscopy. 7. Bronchoscopic procedure scheduled within 30 days of the CT or PET report. 8. Patient qualifies for a procedure using the BF-UCP190F bronchoscope and the ViziShot 2 25 needle based upon the approved indications for use for those devices.

Exclusion criteria

1. Concurrently participating in another competing clinical study. 2. Unwilling or unable to return for follow-up, e.g., plans for relocation, unsuitable transportation. 3. Patient not suitable for flexible bronchoscopy as determined by the treating physician prior to the procedure. 4. Currently on anticoagulation that cannot be paused, or a coagulation disorder that, in the opinion of the investigator, would pose an increased risk of bleeding. 5. Intraprocedural identification of intrinsic and endoscopically visualized endobronchial lesion for which adequate biopsy can be obtained via endobronchial biopsy.

Design outcomes

Primary

MeasureTime frameDescription
Ability to visualize and sample a priori defined lesion in the inner or middle third of the lung with BF-UCP190F.Index ProcedureThe primary endpoint-the proportion of a priori defined inner/middle-third lesions visualized and sampled using the BF-UCP190F-will be summarized using descriptive statistics, including frequency and percentage with 95% confidence intervals.

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026