Skip to content

Mobilization and Outcomes After Venous Closure

MOVE - Mobilization and Outcomes After VEnous Closure - A Prospective Registry of Real-World Outcomes/Usage/Evidence for the MYNX CONTROL™ VENOUS Vascular Closure Device 6F-12F

Status
Active, not recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT07246902
Acronym
MOVE
Enrollment
339
Registered
2025-11-24
Start date
2025-11-24
Completion date
2026-08-21
Last updated
2026-08-10

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Electrophysiology Study, Venous Vascular Closure

Keywords

Electrophysiology Study, Venous closure, Venous access closure, Vascular access closure, Venous Vascular Closure, Vascular closure device, MYNX CONTROL VENOUS, MOVE Registry, MOVE, Cardiac Catheterization, MYNX

Brief summary

The primary objective of this post-market registry is to collect real-world outcomes and evaluate usage practice of MYNX CONTROL™ VENOUS (MCV) Vascular Closure Device (VCD) 6F-12F in sealing femoral venous access sites in patients who have undergone endovascular procedures in a real-world setting.

Detailed description

The study is a single-arm, prospective, multi-center, observational, real-world registry of venous access site closures utilizing MYNX CONTROL™ VENOUS VCD 6F-12F following endovascular procedures. The study will enroll approximately 300 subjects in approximately 15 study sites in the United States.

Interventions

DEVICEMYNX CONTROLTM VENOUS Vascular Closure Device

The MYNX CONTROLTM VENOUS (MCV) Vascular Closure Device (VCD) 6F-12F is indicated for use to seal femoral venous access sites while reducing times to hemostasis and ambulation in patients who have undergone diagnostic or interventional endovascular procedures utilizing 6F to 12F procedural sheaths, with single or multiple access sites in one or both limbs. MCV VCD is designed to achieve femoral vein hemostasis via delivery of the GRIP TECHNOLOGY™ sealant (an extravascular, water-soluble synthetic hydrogel), using a balloon catheter in conjunction with a standard procedural sheath. The sealant is made of a polyethylene glycol (PEG) material which expands upon contact with subcutaneous fluids to seal the venotomy and is resorbed by the body within 30 days. The MCV VCD is supplied with a 10ml locking syringe used for balloon inflation and deflation. The catheter shaft has a silicone lubricant to facilitate insertion and withdrawal into compatible sheaths.

Sponsors

Cordis US Corp.
Lead SponsorINDUSTRY
NAMSA
CollaboratorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

1. Able and willing to provide informed consent and to complete a follow-up visit at 14 ± 7 days post-procedure. 2. Individuals undergoing catheter-based procedures utilizing 6F to 12F inner diameter procedural sheaths, with single or multiple venous access sites in one or both limbs. 3. Individuals who are candidates to have their venous access site(s) closed with MYNX CONTROL™ VENOUS VCD 6F-12F per IFU. 4. At the time of enrollment, the Investigator deems the subject a candidate for same-day discharge (SDD) per standard of care (no procedure related events/complications e.g., no new pericardial effusion, post-procedure diuresis not needed, etc.).

Exclusion criteria

1. Presence of bruit, palpable aneurysm, significant candida or groin infection. 2. Prior to closure, presence of hematoma in the accessed limb. 3. Currently involved in any other clinical trial that may interfere with the outcomes of this study as determined by the Investigator. 4. Planned use of other closure devices or techniques other than MYNX CONTROL™ VENOUS VCD 6F-12F. 5. Life expectancy \<12 months.

Design outcomes

Primary

MeasureTime frameDescription
Rate of patients with same day discharge (SDD) and without subsequent hospitalization/intervention for access-site complicationsFrom time of index procedure through end of following day (within 48 hours)Rate of patients who successfully received a study device at all access sites and had SDD without subsequent hospitalization/intervention for access-site complications either same day post-discharge or the next day
Rate of access-site complicationsFrom time of study device introduction at first access site through 14 days post-procedureRate of access-site complications, assessed per standard of care, through 14 days post-procedure, including: * Access Site-Related Hematoma \> 6 cm documented by ultrasound * Local Access Site Infection confirmed by culture and sensitivity, treated with intramuscular or oral antibiotics * Allergic Reaction * Access site-related bleeding requiring transfusion, surgical intervention, or rehospitalization * Pulmonary embolism requiring surgical or endovascular intervention and/or resulting in death, to be confirmed by CT pulmonary angiography, lung ventilation/perfusion scan (VQ scan), or autopsy * Ipsilateral deep vein thrombosis, documented by ultrasound

Countries

United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Aug 11, 2026