Skip to content

Computer Guided Microwave Liver Ablation

Computer Guided Microwave Liver Ablation

Status
Recruiting
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT07226869
Acronym
MWA Sim
Enrollment
84
Registered
2025-11-12
Start date
2026-05-08
Completion date
2030-02-28
Last updated
2026-05-11

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hepatocellular Carcinoma (HCC)

Keywords

hepatocellular carcinoma, liver neoplasm, primary liver cancer, microwave ablation (MWA), percutaneous ablation, computer-assisted ablation, simulation-guided ablation, 3D ablation planning, treatment planning software, image-guided ablation, local tumor progression

Brief summary

The goal of this clinical trial is to learn if the intraoperative use of a computer guidance software can improve the success of liver tumor ablation in adults. The employed software calculates and displays a simulation of the ablation such that the physician can visualize what portion of the target tumor has, and has not been treated at any point during the procedure. The main questions it aims to answer are: 1) Does the use of the computer guidance software reduce the number of times a tumor is incompletely treated. 2) Does the use of the computer guidance software reduce the rate of local tumor recurrence at 2 year follow-up? 3) Was there an increase or a decrease in medical problems for participants after a procedure where the guidance software was used? Researchers will compare liver tumor treatment using the computer guidance software with an historic control to see if the addition of the guidance software improved the outcomes after an ablation. Participants will: Undergo CT-guided microwave ablation treatment of a liver tumor using computer-assisted simulation. Visit the clinic at one month and then every 3 months for blood tests and a contrast-enhanced CT or MRI imaging study (as per standard of care)

Detailed description

Accublate (NE Scientific, Inc) is a computer-based tumor ablation guidance software that uniquely provides real-time simulation of expected ablation volumes. In a previously reported study of Radiofrequency Ablation, the improved visualization of treated versus untreated target tumor was associated with improved outcomes. This study examines clinical application of the simulation software for microwave ablation (MWA), which will be evaluated in a 24 month two-center clinical trial. At Dartmouth Hitchcock Medical Center (DHMC), and at one other hospital, under IRB approval, adults referred from local Liver Tumor Boards for curative local treatment of up to four Hepatocellular Carcinoma (HCC) tumors of 2-5 cm diameter will be offered participation. After providing informed consent, and meeting inclusion and exclusion criteria, the CT-guided MWA ablation will be performed, with the physician having the benefit of the graphical display of the Accublate MWA simulation guidance software. Prior to the ablation, the software provides 3D graphical display for planning, that includes the tumor, desired margin, and interactive model of the ablation probe and superimposed expected ablation volume at particular energy settings. During placement, the software permits registration of updated image of the actual probe position to original image of the segmented tumor, and with the interactive ablation volume settings, allows assessment of adequacy of targeting. After each activation of the ablation, the calculated simulated ablation volume is provided to indicate what tissues have, and have not, been ablated. These 3D views then provide guidance for intraprocedural adjustments to ensure target coverage by overlapping ablations, if indicated. Patients are routinely admitted for overnight observation and receive IV pain and nausea medication if needed. One month after the ablation, patients will have a follow-up outpatient contrast-enhanced abdominal CT, and from these images, the rate of complete ablation (Technical Efficacy) will be determined. Additionally, patients will be followed at 3 month intervals for 24 months after the ablation to detect any complications, tumor recurrence (Local Tumor Progression), and survival.

Interventions

DEVICEComputer-Assisted Microwave Liver Ablation

Computer-assisted image-processing software used intraoperatively to assist in percutaneous thermal ablation. The software performs segmentation and registration of pre-procedural and intraprocedural imaging, and simulates the expected ablation zone based on probe position, applied energy, and adjacent vascular structures. The output is displayed in 3D multiplanar images to be used by the treating physician to assist in planning, targeting, and intraprocedural decision-making regarding adequacy of ablation coverage. After each ablation activation, the treating physician determines registration accuracy and decides whether any additional ablation is required, based on images of the software estimation of what tissues have and have not been treated.

Sponsors

NE Scientific INC
Lead SponsorINDUSTRY
National Cancer Institute (NCI)
CollaboratorNIH
Dartmouth-Hitchcock Medical Center
CollaboratorOTHER
Massachusetts General Hospital
CollaboratorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Masking description

Imaging outcomes will be assessed by independent radiologists blinded to intervention status

Eligibility

Sex/Gender
ALL
Age
18 Years to 90 Years
Healthy volunteers
No

Inclusion criteria

1. Age ≥ 18 years, with life expectancy of at least 1 year 2. Diagnosis of hepatocellular carcinoma (HCC) confirmed by: * LI-RADS 5 imaging features or * Histopathology * Cirrhosis with AFP \> 400 3. Localized disease without macrovascular invasion or extrahepatic metastasis, eligible for curative-intent percutaneous thermal ablation, defined as: o Up to 5 lesions with at least one lesion, 2 -5 cm, and no lesion \>5 cm diameter 4. Tumor location deemed technically feasible for percutaneous ablation by the treating interventional radiologist 5. ECOG Performance Status 0-2 6. Adequate coagulation status, defined as: * Platelets ≥ 50,000/μL * INR ≤ 1.8 (or correctable) 7. Ability to undergo contrast-enhanced CT or MRI 8. Willingness and ability to provide informed consent

Exclusion criteria

1. Prior local therapy to the target lesion (ablation, TACE, SBRT, or resection) or to a lesion within 1 cm of the target lesion 2. More than 5 hepatic lesions, or any lesion ineligible for technically complete ablation 3. uncontrolled hepatic decompensation, including: o Persistent encephalopathy 4. Uncorrectable coagulopathy or contraindication to percutaneous liver intervention 5. Contraindication to contrast-enhanced imaging (e.g., severe CKD without dialysis, contrast allergy not correctable with premedication) 6. Active systemic infection 7. Pregnancy 8. Inability to comply with follow-up imaging schedule

Design outcomes

Primary

MeasureTime frameDescription
Local Tumor ProgressionAssessed at each imaging follow-up visit ( at every 3 months, up to 24 months).Local Tumor Progression (LTP) is defined as the appearance of new or enlarging nodular or irregular arterial phase enhancement with washout at or within the edge of a previously ablated lesion after an earlier imaging study has demonstrated complete ablation (technical effectiveness). LTP is determined on serial contrast-enhanced CT or MRI according to LI-RADS treatment response criteria or equivalent institutional standards.
Technical Effectiveness1 month post-procedureTechnical Effectiveness is defined as complete ablation of all target tumor tissue, demonstrated by the absence of any nodular or irregular arterial phase enhancement within or along the margin of the ablation zone on the first post-ablation contrast-enhanced imaging study (CT or MRI). This assessment is performed approximately one month after the procedure. Imaging is interpreted according to LI-RADS treatment response criteria (LR-TR) or equivalent institutional criteria.

Countries

United States

Contacts

CONTACTEric Hoffer, MD
hoffer@hitchcock.org1 603 667 0283
STUDY_DIRECTORAndrea Borsic, PHD

NE Scientific INC

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: May 12, 2026