Optimization of Commissural Alignment During Transcatheter Aortic Valve Implantation With Evolut FX+

Optimization of Commissural Alignment During Transcatheter Aortic Valve Implantation With Evolut FX+. A Randomized, Prospective Study.

Status
Not yet recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT07217691
Acronym
ALIGN-EFX
Enrollment
40
Registered
2025-10-16
Start date
2025-11-01
Completion date
2026-05-01
Last updated
2025-10-16

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Aortic Stenosis, Commissural Alignment, Trans-catheter Aortic Valve Implantation

Keywords

TAVI, Commissural alignment

Brief summary

Purpose of the Study The purpose of this study is to investigate how a transcatheter aortic valve (TAVI, biological valve prosthesis) can best be positioned in order to avoid blockage of the coronary arteries by the valve material after implantation. Method The study will include patients undergoing TAVI. Participants will be randomized, meaning that it will be determined by chance which of two established implantation techniques is used. Both techniques are already part of routine clinical practice. Examinations After the procedure, a CT scan will be performed to evaluate the position of the valve in relation to the coronary arteries. This CT scan is the only additional examination beyond today's standard clinical practice. Significance If one of the techniques proves to provide better positioning of the valve, this method may be recommended as standard practice in future treatment. The study will therefore contribute to improved patient safety and treatment quality, as well as increase knowledge about optimal positioning and implantation techniques in TAVI.

Detailed description

The purpose of the present study is to prospectively evaluate the efficacy and safety of a novel patient-specific rotation of the Evolut FX+ TAVI valve and the delivering system during the transfemoral (TF) procedure. Specifically, it aims to evaluate and compare the commonly used fluoroscopic (X-ray) LAO degree for rotation of the delivery system and more patient-specific LAO degree achieved by CT analysis prior to the procedure. The degree of alignment and coronary overlap will be measured with ECG-gated CT after the procedure. Thus, it will prospectively explore if these two techniques differ in obtaining commissural alignment, coronary overlap and safety outcomes following implantation of latest-generation Evolut FX+ valve. We intend to include 40 patients with severe aortic stenosis and in whom TF-TAVI with Evolut FX+ is planned after heart team meeting. Preprocedure CT scan and postprocedure CT scan will be evaluated for commissural alignment.

Interventions

DEVICEImplantation of Evolut FX pluss TAVI device from Medtronic in LAO 25

In this arm the HAT marker will be placed in the outer curvature of descending aorta in LAO 25 degree.

DEVICEImplantation of Evolut FX pluss TAVI device from Medtronic in patient specific degree.

In this arm the HAT marker will be placed in the outer curvature of descending aorta in patient specific degree.

Sponsors

Oslo University Hospital
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

* Patients with severe aortic stenosis indicated for TAVI after heart team meeting. * Age ≥65 years. * Patients planned by the TAVI team to receive a self-expandable valve (Evolut FX+ valve). * Patients providing informed consent.

Exclusion criteria

* Severe peripheral vascular disease preventing transfemoral access. * Prior aortic valve replacement or bicuspid valve. * Severely reduced kidney function (estimated glomerular filtration rate \<30).

Design outcomes

Primary

MeasureTime frameDescription
Achievement commissural alignment.Day 1 (post-procedure CT).Proportion of patients achieving commissural alignment post-TAVI (measured by CT-analysis after TAVI).
Commissural alignment after TAVI measured in degrees.Day 1 (post-procedure CT)Commissural alignment following TAVI, assessed by computed tomography (CT) analysis. Native commissures (measured before TAVI from CT) will serve as the reference. We will measure the number of degrees of all three commissures from the center of the left main artery before and after TAVI to estimate alignment.

Contacts

Primary ContactAhmed Al-Ani, MD/PHD candidate
aalani@ous-hf.no004792831213
Backup ContactTrygve Hall, MD/PHD
tryhal@ous-hf.no004747500700

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026