Skip to content

Intravascular Neuro OCT Imaging System for Aneurysm Treatment Evaluation

Intravascular Neuro OCT Imaging System for Aneurysm Treatment Evaluation

Status
Active, not recruiting
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT07214220
Acronym
INSYTE
Enrollment
67
Registered
2025-10-09
Start date
2026-02-25
Completion date
2029-02-28
Last updated
2026-07-23

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Intracranial Aneurysm

Keywords

Intracranial aneurysm treatment, OCT

Brief summary

This is an investigational study for a new medical device called the nOCT (neuro optical coherence tomography) Imaging System, which is manufactured by Spryte Medical, LLC. The nOCT Imaging System takes pictures from inside a blood vessel in your brain. These pictures give your doctor information about the inside of your blood vessel including the disease and any implanted devices. The nOCT Imaging System consists of a probe and a console. The probe is a small, flexible wire-like device designed to navigate through catheters which have already been inserted in your body as part of your planned procedure. Catheters are small, flexible, tubes inserted in your blood vessels which allow your doctor to deliver treatments such as medications, coils, or stents directly to the affected area. The console is a unit that includes a computer, screen and laser light source. The probe is connected to the console. The console provides the probe with low-power light from the laser which is used to scan and create pictures of your blood vessel. The pictures are displayed on the screen of the console for review by your doctor and may be stored for future viewing. The objective of the study is to evaluate the safety and effectiveness of the nOCT Imaging System to provide quality images for diagnostic assessment during endovascular intracranial aneurysm treatment and follow-up.

Interventions

PROCEDUREEndovascular Intracranial aneurysm treatment

Endovascular Intracranial aneurysm treatment using devices such as coils, flow diverters, etc. The treatment will include devices that are all FDA approved.

DEVICEnOCT imaging

During the aneurysm treatment and during the subsequent follow-up, nOCT imaging will be performed.

Sponsors

Spryte Medical
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 75 Years
Healthy volunteers
No

Inclusion criteria

Subject age ≥ 18 and ≤ 75 years Subject has a pre-procedure mRS ≤ 3 Subject is undergoing a planned treatment for an intracranial aneurysm, unruptured or ruptured Subject understands the investigational procedure, consents to participation, is willing to comply with study follow-up requirements and provides a signed informed consent document Parent artery has a diameter ≥ 1.3 mm and ≤ 6.0 mm as measured by angiography.

Exclusion criteria

Subjects with a minimum platelet count of \< 100,000/μL. Subjects who have suffered an ischemic stroke or transient ischemic attack within the past 30 days. Subject has an acutely ruptured aneurysm with a Hunt \& Hess score ≥ 4 Subject has an infectious, blister-like, fusiform, dissecting, traumatic or mycotic aneurysm confirmed by angiography Subject has challenging anatomy that in the investigator's opinion is not suitable for safe delivery of an 0.021" catheter, including stenosis \> 70% or excessive tortuosity Subject presents with other medical or surgical co-morbidities limiting his/her life expectancy to less than one year Subject is, in the opinion of the investigator, unlikely to comply with the study protocol or follow-up requirements. Subject with any condition which in the opinion of the treating physician would place the subject at an elevated risk of embolic stroke Subject with known allergy or other contraindication to heparin, iodinated contrast, or dual-antiplatelet medication Subject has ipsilateral carotid or vertebral artery stenosis greater than 50% Subject underwent stenting, angioplasty, or endarterectomy procedures of an extracranial (carotid or vertebral artery) or intracranial artery within 30 days prior to treatment. Subject has serious concurrent medical conditions including bacteremia or sepsis, acute renal failure at the time of the procedure, and major coagulation system abnormalities that in the opinion of the investigator could significantly increase risk Subject has severe intracranial vasospasm not responsive to medical therapy Subject has chronic kidney disease stage ≥ 4 and is not undergoing dialysis The subject is pregnant or breastfeeding at the time of admission or plans to become pregnant during their participation in the trial Subject is currently participating in another clinical research trial involving an investigational device or drug Subject is under judicial protection or legal guardianship

Design outcomes

Primary

MeasureTime frameDescription
Safety - Adverse Eventsperi-proceduralAll peri-procedural adverse events (AE) from the index procedure.
Effectivenessperi-proceduralImage quality, defined as clear image length (CIL) for images obtained during the index procedure.

Countries

Argentina, Canada, United States

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Jul 24, 2026