Skip to content

Interest of High-speed Centrifugation for Measuring Anti-Xa Activity on Lipemic Plasma

Interest of High-speed Centrifugation for Measuring Anti-Xa Activity on Lipemic Plasma

Status
Recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT07200674
Acronym
LCGV
Enrollment
150
Registered
2025-10-01
Start date
2024-03-11
Completion date
2025-12-11
Last updated
2025-10-01

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hypertriglyceridemia

Keywords

Hypertriglyceridemia, High-Speed Centrifugation, Anti-Xa Activity, Lipemic Plasma, Hemostasis, Hematology

Brief summary

Some hemostasis techniques require spectrophotometric measurements. These are then subject to interference from the sample's lipemia (postprandial, hypertriglyceridemia, etc.), which risks distorting the results; this is estimated to affect 0.5 to 2.5% of samples. This is particularly the case for anti-Xa activity, a critical test used to monitor anticoagulant treatments. To date, the HUS Hematology Laboratory does not have or is aware of any alternative method to overcome this interference, and is unable to perform anti-Xa activity when the sample has excessive lipemia. This study will evaluate, on samples from routine care artificially overloaded with lipids, the effectiveness of a high-speed centrifugation process (10,800g for 10 minutes).

Interventions

None listed

Sponsors

University Hospital, Strasbourg, France
Lead SponsorOTHER

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Adult patient (≥ 18 years) * Patient anticoagulated with an anti-Xa (UFH, LMWH, fondaparinux, danaparoid, apixaban, rivaroxaban) * Sample sent to the HUS Hematology Laboratory and analyzed for measurement of the anti-Xa activity of an anticoagulant as part of routine care

Exclusion criteria

* Patient with a basal lipidemic sample * Sample of insufficient volume

Design outcomes

Primary

MeasureTime frameDescription
To determine whether high-speed centrifugation (10,800g for 10 minutes) effectively separates the lipid fraction from the rest of the plasmaUp to 10 minutesTo determine whether high-speed centrifugation (10,800g for 10 minutes) effectively separates the lipid fraction from the rest of the plasma, in order to measure anti-Xa activity, and to ensure that this process does not interfere with this measurement.

Countries

France

Contacts

Primary ContactAgathe HERB, PharmD
agathe.herb@chru-strasbourg.fr33 3 88 12 75 53

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026