RFA and Bite Force in COD Teeth

Tooth Stability Assessment in Cemento-Osseous Dysplasia Using Resonance Frequency Analysis and Bite Force Sensor

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT07185711
Enrollment
17
Registered
2025-09-22
Start date
2025-01-02
Completion date
2025-09-15
Last updated
2025-09-22

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Cemento-Osseous Dysplasia, Jaw Diseases / Diagnosis, Tooth Ankylosis

Keywords

pathology, Resonance Frequency Analysis, Bite Force

Brief summary

This study aims to evaluate the periodontal attachment and ankylosis status of teeth associated with cemento-osseous dysplasia (COD). Using resonance frequency analysis (RFA) and a bite force sensor, the stability of COD-associated teeth was measured and compared with contralateral healthy teeth. These non-invasive and objective methods are expected to reveal the impact of COD lesions on the surrounding dentoalveolar structures.

Detailed description

Cemento-osseous dysplasias represent the most common group of benign fibro-osseous lesions, frequently detected in the mandible and often asymptomatic. Although they generally do not require treatment, the remodeling of bone and cementum-like tissues around the tooth roots has clinical significance in terms of periodontal attachment and ankylosis. The present study aims to investigate the ankylosis status of teeth associated with COD lesions at different stages by using objective measurement tools. In each patient, COD-associated teeth and contralateral healthy teeth were evaluated. Measurements were performed using resonance frequency analysis (RFA) with the Osstell™ device and additionally by a bite force sensor to assess functional stability. For RFA, SmartPeg magnetic attachments were fixed to the occlusal surface with composite resin, and three measurements were obtained in both mesio-distal and bucco-lingual directions. Mean ISQ values were then recorded. After measurements, SmartPeg was carefully removed without leaving residues, and patient comfort was evaluated using a six-point numeric rating scale. The obtained RFA and bite force values will be statistically analyzed to compare COD-associated teeth with healthy controls. Furthermore, the study seeks to determine differences in ankylosis tendency across various COD stages and their potential impact on periodontal ligament integrity. This approach may provide valuable insights for understanding the clinical course of COD and for planning surgical interventions in symptomatic cases

Interventions

DIAGNOSTIC_TESTResonance Frequency Analysis (RFA)

Resonance frequency analysis performed with the Osstell™ device. SmartPeg was attached with composite resin to the occlusal surface of the tooth, and ISQ values were recorded in mesio-distal and bucco-lingual directions.

DIAGNOSTIC_TESTBite Force Sensor

Assessment of maximum bite force using a bite force sensor. Measurements were performed on COD-associated teeth and contralateral healthy controls for comparison.

Sponsors

Eskisehir Osmangazi University
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
PARALLEL
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Patients diagnosed with cemento-osseous dysplasia (COD) based on panoramic radiographs * Presence of at least one COD-associated tooth suitable for measurement * Availability of a contralateral healthy tooth to serve as a control * Teeth with healthy periodontal supporting tissues * Patients aged ≥18 years * Patients who have provided written informed consent

Exclusion criteria

* Presence of systemic diseases that could affect bone or periodontal structures (e.g., uncontrolled diabetes, osteoporosis, metabolic bone diseases) * History of radiotherapy or chemotherapy in the head and neck region * Teeth with extensive caries, mobility, or periodontal disease * Patients with a history of orthodontic treatment or trauma in the relevant region

Design outcomes

Primary

MeasureTime frameDescription
Implant Stability Quotient (ISQ) values by Resonance Frequency Analysis (RFA)At baseline (single measurement per tooth)ISQ values obtained from COD-associated teeth and contralateral healthy teeth using the Osstell™ device. Measurements recorded in mesio-distal and bucco-lingual directions and averaged.

Secondary

MeasureTime frameDescription
Maximum Bite ForceAt baseline (single measurement per tooth)Bite force recorded with a bite force sensor to compare functional stability of COD-associated teeth and contralateral healthy teeth.

Countries

Turkey (Türkiye)

Outcome results

None listed