Skip to content

Application of the Off-Clamp And Sutureless Technique in Robot-Assisted Partial Nephrectomy

Application of the Off-Clamp And Sutureless Technique in Robot-Assisted Partial Nephrectomy: A Single-Center, Prospective Cohort Study

Status
Recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT07141225
Enrollment
190
Registered
2025-08-26
Start date
2025-06-01
Completion date
2028-06-30
Last updated
2025-09-05

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Renal and Urinary Disorders, Renal Cancer, Renal Particial

Keywords

robot-assisted partial nephrectomy, off-clamp, sutureless, postoperative renal function preservation

Brief summary

The detection rate of renal masses smaller than 7 cm has significantly increased in recent years. To preserve postoperative renal function to the greatest extent possible, guidelines from the European Association of Urology (EAU), the National Comprehensive Cancer Network (NCCN), and others have endorsed partial nephrectomy (PN) as the preferred treatment strategy for small renal masses. In conventional PN, it is necessary to clamp the renal artery or its branch arteries and employ a double-layer suturing technique to close the resection bed. This controls bleeding, maintains a clear surgical field, and prevents postoperative urinary leakage. The maximum safe duration of warm ischemia to avoid irreversible renal parenchymal damage remains controversial, though most studies indicate a window of 20-30 minutes. Consequently, the off-clamp sutureless concept has gained prominence. Its core principle is to avoid renal artery clamping and replace suturing with novel haemostatic techniques, thereby maximizing the preservation of healthy renal parenchyma. With the diversification of haemostatic material options and the widespread adoption of robotic-assisted systems, the off-clamp sutureless strategy has become technically feasible for small renal masses with low complexity . Multiple retrospective studies demonstrate that the off-clamp sutureless technique is non-inferior, offering safety and surgical outcomes comparable to conventional robot-assisted partial nephrectomy (RAPN). However, it is important to note that current research predominantly focuses on tumors ≤4 cm, is largely retrospective, and suffers from limited sample sizes. More robust, evidence-based medical evidence is required to support its application for larger tumors or those with complex anatomy.

Detailed description

The detection rate of renal masses smaller than 7 cm has increased significantly in recent years. To maximize the preservation of postoperative renal function, guidelines from the European Association of Urology (EAU), the National Comprehensive Cancer Network (NCCN), and others have established partial nephrectomy (PN) as the preferred treatment option for small renal masses. In conventional PN, the renal artery or its segmental branches must be clamped, and the renal defect is typically closed using a multilayer suturing technique to control bleeding, maintain a clear surgical field, and prevent postoperative urinary leakage. The maximum safe duration of warm ischemia time (WIT) remains controversial, though most studies suggest a limit of 20-30 minutes to avoid irreversible renal parenchymal damage. In murine models, renal damage increases steeply after ischemia exceeds 30 minutes. Furthermore, the renorrhaphy suture technique has a steep learning curve, and the suturing process itself can cause additional injury to the renal vasculature, potentially compromising global renal function . Notably, up to 30% of patients with normal preoperative renal function may experience a decline in their estimated glomerular filtration rate (eGFR) to \<60 mL/min/1.73 m² post-surgery, and nearly 10% may suffer a \>50% reduction in renal function . Consequently, the concept of a zero-ischemia sutureless approach has gained traction. Its core principle is to avoid renal artery clamping and replace suturing with novel haemostatic methods, thereby maximizing the preservation of healthy renal parenchyma. With the expanding array of haemostatic agents and the widespread adoption of robotic-assisted systems, the zero-ischemia sutureless strategy has become technically feasible for small renal masses with low complexity. Findings from multiple retrospective studies indicate that the zero-ischemia sutureless technique is non-inferior, demonstrating comparable safety and surgical outcomes to standard robot-assisted partial nephrectomy (RAPN). A study by Antonio Franco et al. reported a median decline in overall renal function of only 10 mL/min after zero-ischemia sutureless surgery, supporting its role as a safe procedure that effectively preserves postoperative renal function and reduces complications. In a review, J. C. Moreno Cortés highlighted that replacing traditional artery clamping and suturing with mono- or bipolar electrocautery and new haemostatic agents offers a simpler and faster method for reconstruction. This approach simplifies the surgical steps without increasing the risk of complications. However, it is important to note that current research is predominantly focused on tumours ≤4 cm, is largely retrospective, and often involves small sample sizes. More robust evidence from prospective studies is needed to support the application of this technique for larger or anatomically complex tumours.

Interventions

PROCEDUREOff-Clamp Sutureless Technique

During the procedure, the renal artery and its branches are not clamped. The tumor is completely resected with a gross margin of 0.5-1 cm from its edge. Monopolar or bipolar electrocautery is used for hemostasis during resection. Following tumor removal, the renal resection bed is subjected to meticulous hemostasis, followed by the application of hemostatic agents without suture closure.

Sponsors

Shao Pengfei
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to 80 Years
Healthy volunteers
No

Inclusion criteria

1. Age between 18 and 80 years old, regardless of gender; 2. Radiological findings demonstrating a tumor size of ≤7 cm; 3. Imaging studies showing no evidence of collecting system invasion; 4. Scheduled to undergo robot-assisted partial nephrectomy (RAPN).

Exclusion criteria

1. Preoperative imaging demonstrating evidence of distant metastasis or lymph node involvement; 2. Unilateral or bilateral multiple lesions not amenable to simultaneous resection; 3. History of prior systemic therapy, including molecular targeted therapy, immunotherapy, or chemotherapy; 4. Intraoperative conversion to radical nephrectomy; 5. Intraoperative conversion to open surgery.

Design outcomes

Primary

MeasureTime frameDescription
Bilateral Kidney GFR3 months after surgeryMeasured by 99mTc-DTPA

Secondary

MeasureTime frame
Perioperative Complication Rate1 week after surgery
Intraoperative Blood Lossduring surgery

Countries

China

Contacts

Primary ContactPengfei Shao, Professor
spf032@hotmail.com+8613851925825
Backup ContactHaoqi Miao, Postgraduate
mhq@stu.njmu.edu.cn

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026