MRI, MRI Image Enhancement
Conditions
Keywords
abdominal MRI, breath-hold technique, functional residual capacity, image quality, non-contrast MRI, liver MRI, end-expiration, preoxygenation, oxygen supplementation, radiology, respiratory motion control, T2-weighted imaging, living liver donor, motion artifact, 3T MRI, UCSF, motion artifact reduction, hyperventilation, end-inspiration
Brief summary
The goal of this interventional study (clinical trial) is to learn if different breath-holding techniques, with and without extra oxygen, can improve the quality of abdominal Magnetic Resonance Imaging (MRI) images in healthy adults, ages 18-75. The main questions it aims to answer are: * Does breath-holding at end-expiration improve image quality in abdominal MRI scans? * Does adding oxygen while breath-holding further reduce motion artifacts in abdominal MRI scans? Researchers will compare breath-holding with and without oxygen to see if using oxygen improves image quality during MRI scans. Participants will: * Be pre-screened for MRI safety and trained on breath-hold procedures * Have one non-contrast abdominal MRI scan at the University of California San Francisco (UCSF) China Basin Imaging Center * Use two different breath-holding techniques during the scan, with and without oxygen * Complete one study visit lasting about 45 minutes to 1 hour
Detailed description
This is a within-subject, randomized crossover interventional study conducted at UCSF China Basin Imaging Center using a 3 Tesla Magnetic Resonance Imaging (3T MRI scanner). The study aims to optimize abdominal MRI protocols by evaluating the impact of breath-holding techniques, with and without oxygen supplementation, on motion artifacts and overall image quality. Each participant will undergo non-contrast abdominal MRI scans using two breath-hold conditions: (1) Functional Residual Capacity (FRC)/end-expiration without oxygen and (2) FRC/end-expiration with preoxygenation. The order of these conditions will be randomized to control for potential order effects, and each participant will serve as their own control to reduce inter-individual variability. T2-weighted and Magnetic Resonance Cholangiopancreatography (MRCP) sequences will be acquired during each breath-hold trial. MRI-compatible pulse oximetry will be used to monitor oxygen saturation and pulse rate throughout scanning. A radiology research nurse will be present if additional monitoring is needed based on the participant's pre-screening or intra-scan findings. Participants will receive training on breath-hold procedures prior to imaging to improve consistency and comfort during scanning. Two board-certified radiologists, blinded to the breath-hold condition, will independently assess each image set for motion artifacts and overall image quality using a standardized 5-point grading system. The grading will range from very poor (1) to very good (5) based on sharpness, visibility of anatomical details, and presence of blurring or signal loss. Inter-rater reliability will be evaluated using the Intraclass Correlation Coefficient (ICC). Statistical analyses will include repeated measures ANOVA to compare image quality scores across breath-holding conditions. Descriptive analyses will assess breath-hold durations and participant characteristics (e.g., age, gender) in relation to image quality and safety outcomes, including oxygen saturation and self-reported comfort. This study involves minimal risk, does not utilize contrast agents, and is intended to support the development of motion-reduced, efficient liver MRI protocols, particularly for living liver donor evaluation. Data collected during the study will not be used for clinical decision-making.
Interventions
Functional Residual Capacity/End-Expiration (breath-hold technique) with/without oxygen to optimize MRI image quality.
Sponsors
Study design
Eligibility
Inclusion criteria
* Subject must be within 18-75 years of age; * Subject must be able to hear and understand instructions without assistive devices; * Subject must provide written informed consent; * Subject has the necessary mental capacity to understand instructions, and is able to comply with protocol requirements; * Subject is able to remain still for duration of imaging procedure (approximately 30-45 minutes)
Exclusion criteria
* Subjects with a weight greater than 499 lbs; * Subjects that have metallic/conductive or electrically/magnetically active implants without Magnetic Resonance (MR) Safe or Magnetic Resonance (MR) Conditional labeling, with the exception of dental devices/fillings, surgical clips, and surgical staples determined to be safe for MRI scanning by a physician investigator; * Subjects that have implants with MR Unsafe labeling; * Subjects that have implants labeled as MR Conditional by the manufacturer for which the allowable conditions are not expected to be achieved by the MR environment or scan protocol; * Subjects who have a contraindication to MRI per the screening policy of the participating site; * Subjects with any respiratory or cardiovascular condition that could compromise safe breath holding; * Subjects who are female and pregnant
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| Liver MRI Image Quality (Motion Artifacts) | During the single MRI session (approximately 1 hour) | Image quality of liver MRI scans will be assessed by quantifying the degree of respiratory motion artifacts under two breath-holding conditions: Functional Residual Capacity (FRC) alone and FRC with oxygen supplementation. Reduced artifacts indicate improved image clarity and feasibility of the technique. Unit of Measure: Motion artifact score (ordinal scale, e.g., 1-5). |
Secondary
| Measure | Time frame | Description |
|---|---|---|
| Breath-Holding Duration | During the MRI session (approximately 1 hour) | The duration (in seconds) that participants can comfortably sustain a breath-hold under each condition (FRC alone and FRC with oxygen supplementation). Unit of Measure: Seconds. |
| Oxygen Saturation During Breath-Holding | During the MRI session (approximately 1 hour) | Peripheral oxygen saturation will be monitored during each breath-hold condition to assess physiologic tolerance and safety. Unit of Measure: Percent oxygen saturation (%). |
| Adverse Events and Participant-Reported Discomfort | During and immediately after the MRI session (up to 1 hour) | Number and type of adverse events, as well as participant-reported discomfort, occurring during or immediately after each breath-hold condition. Unit of Measure: Number of events. |
Countries
United States
Contacts
University of California, San Francisco