Skip to content

µQFR for Branch Stenosis After Single Stent in Bifurcation Lesions

Diagnostic Performance of µQFR for Residual Functional Stenosis in Bifurcation Lesions After Single-stenting Strategy

Status
Recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT07116083
Enrollment
290
Registered
2025-08-11
Start date
2025-08-13
Completion date
2026-10-31
Last updated
2026-02-02

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Coronary Artery Disease, Coronary Artery Disease (Left Main), Obstructive Coronary Artery Disease, Stent Implantation

Keywords

Functional Flow Reserve, Quantitative Flow Ratio

Brief summary

Murray-law based single-view quantitative flow ratio (µQFR) has been recommended for guiding percutaneous coronary intervention (PCI) in selective patients. However, it's reliability has not been validated in bifurcation lesions which present complex anatomy and flluid conditions before and after PCI. The goal of this study is to investigate the diagnostic performance of µQFR in side branch after single-stent treatment for bifurcation lesions in patient with obstructive coronary artery diseases.

Detailed description

The Murray law-based quantitative flow ratio (µQFR), derived from single-view angiography, is an established computational method for non-invasive functional assessment of coronary stenoses. Its utility in guiding percutaneous coronary intervention (PCI) in selected patients with straightforward lesions is recognized. However, its diagnostic reliability remains unvalidated in the context of coronary bifurcation lesions. These lesions exhibit inherent geometric and hemodynamic complexity due to altered flow patterns and shear stress distribution, both pre- and post-intervention. This complexity is particularly pertinent to side branches following single-stent strategies. Significant alterations in the local hemodynamic environment occur after stent deployment in the main vessel, potentially impacting side branch physiology and the accuracy of µQFR calculations specifically within this branch. Consequently, an evidence gap persists regarding the performance of µQFR for functional evaluation of the side branch after bifurcation PCI. This study specifically aims to evaluate the diagnostic performance of µQFR for assessing the functional significance of side branch stenoses after single-stent treatment of bifurcation lesions in patients with obstructive coronary artery disease (CAD). The primary objective is to determine the diagnostic performance of post-procedural µQFR measurements within the side branch of such complex lesions. The second objective is to investigate potential factors influencing the diagnostic performance of µQFR.

Interventions

None listed

Sponsors

Shanghai Zhongshan Hospital
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Age ≥ 18 years and provision of written informed consent for biospecimen donation upon hospital admission. 2. Clinical suspicion or diagnosis of CAD requiring coronary angiography and physiological assessment. 3. Angiographically confirmed true bifurcation lesions, including but not limited to: left main-left anterior descending-left circumflex (LM-LAD-LCx), left anterior descending-diagonal (LAD-Dg), left circumflex-obtuse marginal (LCx-OM), and right coronary artery-posterior left ventricular-posterior descending artery (RCA-PLV-PDA). 4. Bifurcation lesion vessel diameter ≥ 2.5 mm with visually estimated angiographic diameter stenosis ≥ 50%.

Exclusion criteria

1. Acute myocardial infarction. 2. Cardiogenic shock or severe heart failure (Killip class IV). 3. Serum creatinine \> 150 μmol/L or estimated glomerular filtration rate (eGFR) \< 45 mL/min/1.73 m² calculated using the CKD-EPI formula. 4. Known allergy to iodinated contrast media. 5. History of coronary artery bypass graft surgery.

Design outcomes

Primary

MeasureTime frameDescription
Diagnostic accuracy of µQFR in side branchPerioperativeThe diagnostic accuracy of µQFR in assessing ischemia in the side branch, using FFR as the gold standard, following main vessel stenting.

Secondary

MeasureTime frameDescription
Diagnostic accuracy of µQFR in main branchPerioperativeThe effect of intravascular ultrasound (IVUS)-derived parameters on the diagnostic performance of µQFR in assessing ischemia in the main branch before and after stenting, using FFR as the gold standard.

Countries

China

Contacts

CONTACTChenguang Li, MD, PhD
li.chenguang@zs-hospital.sh.cn008664041990
CONTACTJinying Zhou, MD, PhD
zhou.jinying@zs-hospital.sh.cn

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026