Skip to content

Intraoperative Fluorescence-Guided Aspirate Tissue Monitoring of 5-ALA During Brain Tumor Surgery

ATM 5-ALA: Intraoperative Fluorescence-Guided Aspirate Tissue Monitoring of 5-ALA During Brain Tumor Surgery

Status
Recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT07111182
Acronym
ATM5-ALA
Enrollment
8
Registered
2025-08-08
Start date
2025-10-27
Completion date
2027-12-30
Last updated
2025-11-12

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Brain Neoplasms

Brief summary

Gliomas are tumors that occur in all ages; they include the most common malign primary central nervous system tumors in developed countries. Gliomas are often aggressive, and their recommended treatment is surgical resection and chemoradiation. Complete tumor removal is challenging because of diffuse cell growth and the proximity of functionally critical tissues. The current golden standard for intraoperative glioma detection is fluorescence-guided surgery (FGS) using 5-ALA. In 5-ALA FGS the drug-induced fluorescence helps to visually detect tumor cells, which improves resection rates and delays tumor progression. Tumor cells are often left unnoticed because of visual obstacles or weak fluorescence, which may lead to local recurrence and reoperations. Surgical suction devices are routinely used to remove cancerous tissues, but so far, the analysis of the suction waste has not been used in near real-time tissue detection.

Detailed description

A novel medical device (HIVEN®) detects 5-ALA-induced fluorescence from the surgical suction and gives sound feedback to the operating surgeon indicating tumor tissue and overcoming the challenges is the contemporary FGS methods. The 5-ALA (Gleolan, NX Development Corp) has been already FDA-approved since 2017 for fluorescence-guided resection of suspected WHO grade 3 or 4 gliomas. The HIVEN® device has been investigated in Europe during 33 surgeries and the MDR (EU) 2017/745 approval was granted on 09/2025.The device is commercially available in the EU starting from 09/2025. The CE mark is approved for a Class IIb device risk classification. The current medical device study aims to demonstrate the feasibility and the benefit-risk ratio of HIVEN® for detecting tumor fluorescence from the surgical suction waste as a part of the FDA medical device process. The feedback from the device is expected to provide supplementary information on fluorescence and add value to fluorescence-guided surgical workflow.

Interventions

DEVICEHIVEN Medical Device

A medical device (HIVEN®) detects 5-ALA-induced fluorescence from the surgical suction and gives sound feedback to the operating surgeon indicating tumor tissue and overcoming the challenges is the contemporary FGS methods. The device is used for detecting fluorescence of flowing tissues within a transparent tube and providing auditory feedback of tissue fluorescence for neurosurgeons. There is no patient contact intended with this device.

Sponsors

Marginum Ltd.
CollaboratorINDUSTRY
University of Illinois at Chicago
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DEVICE_FEASIBILITY
Masking
NONE

Intervention model description

In general, the current literature favors more and more aggressive treatments for high-grade III-IV (Barak et al. 2021), grade II (Rossi et al. 2020), and both non-symptomatic and symptomatic low-grade gliomas with progressive features (Zeng et al. 2021).

Eligibility

Sex/Gender
ALL
Age
18 Years to 99 Years
Healthy volunteers
No

Inclusion criteria

- * Patient admitted to neurosurgery department for surgical resection of a suspected grade 3 or 4 glioma with 5-ALA (cases) * Patient admitted to neurosurgery department for surgical resection of a primary of secondary brain tumor with no 5-ALA (controls) * Patients aged 18 years old or older (all patients) * Informed consent obtained (all patients)

Exclusion criteria

* Patient belongs to the following vulnerable groups: children, pregnant, prisoners or intellectually disabled. * The participants are not randomized. Randomization is not conducted as the number of eligible patients is limited, subjecting to a long recruitment period that reciprocally increases the bias from uncontrollable (evolving) surgical techniques and adjunct treatments. * The patients are screened and informed of the study before the surgical operation and enrolled after verification of eligibility and written informed consent has been received. Potential study participants are identified from the clinic's planned or urgent surgeries list. The participants are contacted before the operation by the research staff and/or the physician responsible for the treatment. The participants are provided with written and oral information about the research and the time to consider their participation. Finally, the participants are asked for their informed consent and enrolled to the study.

Design outcomes

Primary

MeasureTime frameDescription
Demonstrate the increased detection of fluorescence during surgery (performance)During procedure video recordingFluorescence detection rate during surgery measured per seconds of video (performance)
Assess the safety and benefit-risk profile versus a legally marketed alternative therapy i.e. visual fluorescence guidance (safety)During procedure user's questionnairesBenefit-risk profile based on user's systematic questionnaires indicates non-inferiority to visual fluorescence guidance (safety)

Countries

United States

Contacts

Primary ContactFady T Charbel, MD
fcharbel@uic.edu312-996-4842
Backup ContactLinda Rose-Finnell, MPA
lfinnell@uic.edu312-996-4842

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026