Skip to content

Three-dimensional Accuracy of Direct Digital Scanning for All on Four Implants in Comparison to a Custom-made Verification Jig in Fully Edentulous Patients

Three-dimensional Accuracy of Direct Digital Scanning for All on Four Implants in Comparison to a Custom-made Verification Jig in Fully Edentulous Patients

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT07106177
Enrollment
22
Registered
2025-08-06
Start date
2024-06-03
Completion date
2025-07-10
Last updated
2025-08-06

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Edentulism

Brief summary

The aim of this study is to assess the three-dimensional accuracy of direct intraoral scanning in All-on-4 implant-supported prostheses by comparing intraoral scan data with a custom-made verification jig.

Interventions

OTHERScanning with verification jig

Comparing Relative Implant Positions of the 4 implants in each case obtained through desktop scanning of intraoral provisional verification jig. All-on-4 treatment for mandibular and maxillary edentulous cases were scanned using the Medit i700 intraoral scanner. Scan data were imported into Exocad software, where scan-body matching was performed using the Neodent library to determine the positions of multiunit abutment analogues.

OTHERDirect intraoral scanning

Comparing Relative Implant Positions of the 4 implants in each case obtained through direct intraoral scanning without jig. All-on-4 treatment for mandibular and maxillary edentulous cases were scanned using the Medit i700 intraoral scanner. Scan data were imported into Exocad software, where scan-body matching was performed using the Neodent library to determine the positions of multiunit abutment analogues.

Sponsors

Alexandria University
CollaboratorOTHER
Yasser Ahmed
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

* Patients with complete mandibular edentulism. * Patients requiring full-arch rehabilitation with an All-on-4 implant concept. * Absence of systemic conditions that could affect bone healing or osseointegration. * Adequate bone volume in the anterior mandible for implant placement without the need for additional grafting. * Patients capable of maintaining oral hygiene

Exclusion criteria

* Patients with uncontrolled systemic diseases (e.g., diabetes, osteoporosis). * History of head and neck radiation therapy. * Severe parafunctional habits (e.g., bruxism). * Patients with inadequate bone volume requiring extensive grafting procedures. * Active periodontal or oral infections.

Design outcomes

Primary

MeasureTime frameDescription
Vertical Deviationthrough study completion, an average of 1 yearAnalogues Saved from the Intraoral scan and those saved from stone model were superimposed. The vertical discrepancy (mm) in implant position between intraoral digital scanning and verification jig-based stone model in All-on-4 implant cases.
Angular deviationthrough study completion, an average of 1 yearAnalogues Saved from the Intraoral scan and those saved from stone model were superimposed. The angular difference (degrees) in implant position between intraoral digital scanning and verification jig-based stone model in All-on-4 implant cases.
Horizontal deviationthrough study completion, an average of 1 yearAnalogues Saved from the Intraoral scan and those saved from stone model were superimposed. The horizontal discrepancy (mm) in implant position between intraoral digital scanning and verification jig-based stone model in All-on-4 implant cases.

Countries

Egypt

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026