Edentulism
Conditions
Brief summary
The aim of this study is to assess the three-dimensional accuracy of direct intraoral scanning in All-on-4 implant-supported prostheses by comparing intraoral scan data with a custom-made verification jig.
Interventions
Comparing Relative Implant Positions of the 4 implants in each case obtained through desktop scanning of intraoral provisional verification jig. All-on-4 treatment for mandibular and maxillary edentulous cases were scanned using the Medit i700 intraoral scanner. Scan data were imported into Exocad software, where scan-body matching was performed using the Neodent library to determine the positions of multiunit abutment analogues.
Comparing Relative Implant Positions of the 4 implants in each case obtained through direct intraoral scanning without jig. All-on-4 treatment for mandibular and maxillary edentulous cases were scanned using the Medit i700 intraoral scanner. Scan data were imported into Exocad software, where scan-body matching was performed using the Neodent library to determine the positions of multiunit abutment analogues.
Sponsors
Study design
Eligibility
Inclusion criteria
* Patients with complete mandibular edentulism. * Patients requiring full-arch rehabilitation with an All-on-4 implant concept. * Absence of systemic conditions that could affect bone healing or osseointegration. * Adequate bone volume in the anterior mandible for implant placement without the need for additional grafting. * Patients capable of maintaining oral hygiene
Exclusion criteria
* Patients with uncontrolled systemic diseases (e.g., diabetes, osteoporosis). * History of head and neck radiation therapy. * Severe parafunctional habits (e.g., bruxism). * Patients with inadequate bone volume requiring extensive grafting procedures. * Active periodontal or oral infections.
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| Vertical Deviation | through study completion, an average of 1 year | Analogues Saved from the Intraoral scan and those saved from stone model were superimposed. The vertical discrepancy (mm) in implant position between intraoral digital scanning and verification jig-based stone model in All-on-4 implant cases. |
| Angular deviation | through study completion, an average of 1 year | Analogues Saved from the Intraoral scan and those saved from stone model were superimposed. The angular difference (degrees) in implant position between intraoral digital scanning and verification jig-based stone model in All-on-4 implant cases. |
| Horizontal deviation | through study completion, an average of 1 year | Analogues Saved from the Intraoral scan and those saved from stone model were superimposed. The horizontal discrepancy (mm) in implant position between intraoral digital scanning and verification jig-based stone model in All-on-4 implant cases. |
Countries
Egypt