Skip to content

Strontium-Hydroxyapatite Coated Mini-Screws: Antibacterial Effect and Stability

Evaluation Stability the Antibacterial Efficacy and of Strontium Incorporated Hydroxyapatite [Sr-HA] Coated Mini-screws Used for Maxillary Canine Retraction: A Randomized Clinical Trial

Status
Recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT07105969
Enrollment
20
Registered
2025-08-06
Start date
2025-05-14
Completion date
2026-05-14
Last updated
2025-08-26

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Gingival Inflammation and Loss the Orthodontic Mini-screws

Keywords

▪️Sr-HA ▪️Mini-screw stability ▪️Antibacterial afficacy

Brief summary

This randomized controlled clinical trial aims to evaluate the antibacterial efficacy and stability of strontium-incorporated hydroxyapatite (Sr-HA) coated orthodontic mini-screws (OMSs) used for maxillary canine retraction. A double-blind, split-mouth design was employed, involving 20 patients (aged 16-20 years), each receiving two titanium alloy mini-screws (1.6 mm × 8 mm): one coated with Sr-HA (5% concentration via electrochemical deposition) and one uncoated control. A total of 40 mini-screws were assessed. Following upper first premolar extractions, canine retraction was initiated using 150 g NiTi coil springs on 17×25 SS archwires. Mini-screws were placed between the upper second premolar and first molar without flap elevation or pilot hole drilling. Parameters including screw stability, antimicrobial activity, and gingival blood flow were monitored over a 4-month period. The incorporation of Sr-HA is hypothesized to enhance mini-screw osseointegration, reduce peri-implant inflammation, and improve clinical outcomes by leveraging the osteogenic and antibacterial properties of strontium. This study aims to provide evidence supporting the use of Sr-HA coatings to reduce mini-screw failure rates in orthodontic treatment.

Detailed description

Aim of the study: The aim of this study is to evaluate the antibacterial efficacy and stability of strontium- incorporated hydroxyapatite (Sr-HA) coated orthodontic mini- screws used in maxillary canine retraction in comparison to uncoated mini- screws. Material and methods: 1. All patients will be treatment with fixed appliance and Roth type brackets where leveling and alignment will be done utilizing nickel titanium. 2. Extraction the upper first premolars and retraction the canine will be done using 17 ×25 SS wire. 3. A periapical X-ray will be taken to confirm the mini screw position to avoid interference with adjacent root and to ensure that there are no periapical lesion. 4. Symmetrical orthodontic miniscrews will be inserted between the second premolar and first molar. 5. The OMSs that will be used in this study will be self-drilling, conical in shape, 1.6 mm in diameter, and 8 mm in length, constructed of titanium alloy, i well be purchased from Dentaurum company \[Germany\]. 6. The orthodontic main screws were loaded with a 150 g NiTi coil spring. 7. On one side, a coated will be inserted, and on the other side, an uncoated will be used for the same patient. 8. Coated materials will utilize \[Strontium incorporated hydroxyapatite\] applied by electrochemical deposition and concentration percentage about 5 % . 9. No mucoperiosteal flap will be raised, and no pilot hole will be made during the procedure. 10. Will be assessed throughout follow-up periods of up to four months. Outcome Measurement: 1. Assessment Orthodontic mini-screws stability (coated and uncoated) using Periotest device . 2. Evaluate antimicrobial effect of Strontium incorporated Hydroxyapatite using Enzem- Linked Immunosorbent technique . 3. Evaluate blood flow by periodental probe. 4. Gingival health by visual assessment .

Interventions

OTHERStrontium Incorporated Hydroxyapatite [Sr-HA] coated mini-screws purchased from Dentarum company

Maxillary canine retraction by mini-screw loaded with 150g Niti coil spring

Sponsors

Mansoura University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
TRIPLE (Subject, Investigator, Outcomes Assessor)

Eligibility

Sex/Gender
ALL
Age
16 Years to 20 Years
Healthy volunteers
Yes

Inclusion criteria

1. Adult patients within an age range (16-20) years. 2. Orthodontic treatment plan requiring the extraction of the upper first premolars. 3. Patients have fully permanent teeth are erupted (third molars are not included). 4. No previous orthodontic treatment 5. No medical problem that could interfere with treatment.

Exclusion criteria

1. Presence of problematic healing such as, compromised immune defense, bleeding disorder, pathological bone quality, and xerostomia. 2. Inadequate oral hygiene. 3. Heavy smoking

Design outcomes

Primary

MeasureTime frameDescription
Orthodontic mini-screws stabilityFour mounthMean value of orthodontic mini-screw stability assessed using the Periotest device Measurement Tool: A Periotest device (manufactured by Medizintechnik Gulden, Germany) will be used to evaluate the mechanical stability of the orthodontic mini-screws. Unit of Measure: Periotest Values (PTV), expressed as numerical values ranging from -8 (high stability) to +50 (low stability). Assessment Method: The stability of both coated (Strontium-incorporated Hydroxyapatite) and uncoated orthodontic mini-screws will be measured and compared at specific time intervals throughout the study period.

Secondary

MeasureTime frameDescription
Anti microbial effectFour mounthMean concentration of bacterial adhesion on orthodontic mini-screw surfaces assessed by Enzyme-Linked Immunosorbent Assay Measurement Tool: Enzyme-Linked Immunosorbent Assay (ELISA) will be employed to quantify the level of bacterial colonization on the surface of the mini-screws. Unit of Measure: Colony Forming Units per milliliter (CFU/mL), or Optical Density (OD) values at a specific wavelength (typically 600 nm), depending on the ELISA protocol used. Assessment Method: The antimicrobial effect of the Strontium-incorporated Hydroxyapatite coating will be evaluated by comparing the level of bacterial adhesion on coated versus uncoated mini-screw surfaces.

Countries

Egypt

Contacts

Primary ContactHind H jasim Al-khazrajy, Bachelors
hindhhjk@gmail.com01555178219

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026