Feasibility and Safety of the Augmented Reality Guidance Software TAVIPILOT Software During Transcatheter Aortic Valve Replacement (TAVR/TAVI)

Feasibility and Safety of the Augmented Reality Guidance Software TAVIPILOT Software During Transcatheter Aortic Valve Replacement (TAVR/TAVI)

Status
Not yet recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT07100340
Acronym
SAITO 1B
Enrollment
10
Registered
2025-08-03
Start date
2025-09-15
Completion date
2026-03-15
Last updated
2025-08-03

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

TAVI(Transcatheter Aortic Valve Implantation)

Brief summary

The TAVIPILOT Software by Caranx Medical is an advanced intraoperative assistance tool designed to enhance the accuracy of transcatheter aortic valve positioning during TAVI. It works alongside conventional fluoroscopy, using real-time image analysis to provide precise anatomical landmarks. TAVIPILOT Software detects key anatomical structures, tracks valve positioning, and uses AI-based confidence indicators to assist in alignment. The software is compatible with approved C-arm imaging systems and specific catheter models. The objective is to assess the feasibility and safety of the TAVIPILOT Software augmented reality guidance software during TAVI procedures, aiming to improve valve positioning precision and, implicitly and to reduce implantation depth variations.

Interventions

TAVR procedure with TAVIPILOT augmented reality guidance software operating during the procedure, enabling clinicians to assess the live analysis and recommendations provided by the software.

Sponsors

Caranx Medical
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
65 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Patients aged ≥65 2. Indicated for transfemoral TAVR for severe aortic stenosis

Design outcomes

Primary

MeasureTime frameDescription
Investigational device-related safetyperiproceduralThe primary objective is to evaluate investigational device-related safety, including the occurrence of investigational device-related conversion to open-heart surgery, investigational device-related valve embolization.

Secondary

MeasureTime frameDescription
Device usabilityPeriproceduralEvaluate clinical usability, assessed through customized questionnaires measuring clinician satisfaction, perceived ease of use, and integration of the devices into the procedural workflow.