Biological Reaction of Direct 3d Printed Retainers

Evaluation of Biological Reaction of Direct Three Dimensional Printed Retainers

Status
Recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT07098325
Enrollment
26
Registered
2025-08-01
Start date
2025-10-01
Completion date
2027-06-01
Last updated
2025-08-01

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Orthodontic Retainers

Keywords

Different thicknesses, Direct three dimensional printed retainers, Bacterial growth, Color change

Brief summary

The aim of this study will be to evaluate the biological reaction of direct three dimensional printed retainers. Primary objective is to evaluate bacterial growth and color stability between different thicknesses of 3d printed material used as a retainer . Secondary objective is to determine the optimal thickness for use in clear aligner fabrication based on biological performance.

Detailed description

Retainers are routinely fitted at the end of active orthodontic treatment to allow the teeth to adjust to their new positions The growing demand has led to constant improvements in materials and technologies offered by a rising number of different companies. In recent years, major technological innovations in 3D printing, especially related to computer-aided design, biomaterials and manufacturing techniques, have enabled the production of in-office direct printed Retainers (DPRs) - representing an innovation compared to the traditional thermoformed Retainers. Insufficient cleaning will lead to microbe's growth in retainers. The mostly found microbes are candida and staphylococcus that may include MRSA strains. Once the biofilms are formed in the retainer it's quite difficult to remove that biofilm which shows resistance to antimicrobials and difficult to clear. orthodontic retainers hinder the sterilizing effect of saliva, which further promotes the rapid division, reproduction, and growth of colonized bacteria. Staphylococcus aureus is most commonly found on the retainers and tends to cause bloodstream infections which can lead to serious other infections. While several studies have assessed tooth movement, and biomechanical and clinical effects according to the design of attachments, studies investigating the thickness of the CAs are limited

Interventions

DEVICEretainer with .5 mm thickness

direct 3d printed retainer with .5 mm thickness

DEVICEretainer with 1 mm thickness

direct 3d printed retainer with 1 mm thickness,

Sponsors

Al-Azhar University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

* -Finished fixed orthodontic therapy and seeking for retention as a part of their original treatment plan. * Good oral hygiene. * No habits (e.g., smoking)

Exclusion criteria

* Medication affecting saliva. * intrinsic tooth discoloration. * Uncooperative patients. * Patient with periodontitis. * Learning difficulties and inability to read written instructions.

Design outcomes

Primary

MeasureTime frameDescription
Bacterial growth measured using colony-forming unit (CFU) count on agar plates.from day 0 (Baseline time ) to 14 days after insertionSaliva samples will be collected from each participant at baseline and at day 14. Samples will be cultured on standard agar plates under aerobic conditions. After incubation, bacterial colonies will be counted, and results will be expressed in colony-forming units per milliliter (CFU/ml). A higher CFU value indicates greater bacterial growth. Units: CFU/ml
Color change of 3D printed retainers measured using spectrophotometer; ΔE calculated at day 0 and day 14.from day 0 (baseline time ) to 14 days after insertionThe color stability of the retainers will be assessed using a spectrophotometer (VITA Easyshade or equivalent). Color difference (ΔE) will be calculated between baseline and day 14. A ΔE \> 3.3 is considered clinically perceptible. Scale range: 0-10; higher ΔE score indicates greater color change and worse color stability. Units: ΔE (Delta E) score

Countries

Egypt

Contacts

Primary ContactNorhan Ibrahim Eldsokee Master's Candidate, B.D.S
noureldsokee@gmail.com+20 01559921144

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026