Joint Hyperlaxity and Volar Plate Dynamics: MRI-Based Comparative Evaluation of the PIP Joint

Joint Hyperlaxity and Volar Plate Dynamics: MRI-Based Comparative Evaluation of the PIP Joint

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT07082075
Enrollment
32
Registered
2025-07-24
Start date
2023-05-15
Completion date
2024-05-15
Last updated
2025-07-24

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hypermobility, Joint

Keywords

volar plate, hypermobility, biomechanics

Brief summary

Background: The volar plate (VP) is a key stabilizer of the proximal interphalangeal joint (PIPJ), and its biomechanical behavior may be altered in individuals with joint hypermobility. Objective: This study aimed to evaluate the spatial dynamics of the VP and its relationship with the center of joint motion and flexor digitorum profundus (FDP) tendon in individuals with and without joint hyperlaxity using MRI. Methods: Thirty-two healthy volunteers (16 hyperlax, 16 controls) underwent MRI imaging of both index fingers at five flexion angles (0°, 30°, 60°, 90°, full flexion) and under passive and isometric loading conditions. Key parameters measured included distances from the joint center to VP attachments, VP-FDP tendon distance, and the length between VP ends.

Interventions

None listed

Sponsors

Baskent University Ankara Hospital
CollaboratorOTHER
Hacettepe University
Lead SponsorOTHER

Study design

Observational model
CASE_CONTROL
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 65 Years
Healthy volunteers
Yes

Inclusion criteria

* between 18-65 years

Exclusion criteria

* any history of acute or overuse injuries to the examined hand, * any prior surgical procedures on the examined upper extremity.

Design outcomes

Primary

MeasureTime frameDescription
The Distance Between the Center of Motion (CoM) and the VPLip and VPTipbaselineThe distances between the center of motion (CoM) and the volar lip of the middle phalanx base (VPLip), and between the CoM and the proximal end of the volar plate at its attachment to the volar base of the proximal phalanx (VPTip), were measured using RadiAnt DICOM Viewer software (version 2024.1) in various PIPJ angles.
The Distance Between VPLip and VPTipbaselineThe distance between the volar lip of the middle phalanx base (VPLip), and the proximal end of the volar plate at its attachment to the volar base of the proximal phalanx (VPTip) measured using RadiAnt DICOM Viewer software (version 2024.1) in various PIPJ angles. The purpose of this measurement was to observe how the distance between the two ends of the volar plate changes with varying joint angles.
The Distance Between Volar Plate (VP) and FDP TendonbaselineThe distance between the midpoint of the volar plate (VP) and the flexor digitorum profundus (FDP) tendon was measured using RadiAnt DICOM Viewer software (version 2024.1) at various proximal interphalangeal joint (PIPJ) angles. The purpose of this measurement was to observe how this distance changes across different flexion angles.
Changes Observed During Grasping and Isometric ContractionbaselineMeasurements at all flexion angles were conducted under two conditions: while passively grasping a cylindrical object (without force) and during isometric contraction (with force).

Countries

Turkey (Türkiye)

Outcome results

None listed