Skip to content

Wearables and Artificial Intelligence in Advanced Heart Failure Care

Advancing Proactive Care in Advanced Heart Failure: Integrating AI and Continuous Remote Monitoring for Early Detection of Heart Failure Deterioration

Status
Not yet recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT07051356
Acronym
WAI-HF
Enrollment
200
Registered
2025-07-04
Start date
2025-07-31
Completion date
2027-08-31
Last updated
2025-07-04

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Advanced Heart Failure

Keywords

Advanced heart failure, Wearable device, Artificial intelligence, Remote monitoring, Left ventricular assist device

Brief summary

The goal of this observational study is to evaluate whether AI-based analyses of wearable sensor data can identify early signs of deterioration leading to hospitalization in patients with advanced heart failure. The main questions it aims to answer are: * Can AI-driven analysis of wearable data detect physiological or behavioral changes associated with impending hospital admissions? * Does wearable-based remote monitoring influence daily exercise duration in patients with advanced heart failure. * Is wearable-based remote monitoring usable and acceptable for patients with advanced heart failure in a real-world setting? Participants will wear a wrist-worn (Fitbit) device continuously for one year and will use an eHealth app to answer question about their symptoms. Participant's physical activity, heart rate, heart rate variability, respiratory rate, sleep quality, and symptomatic status will be monitored remotely.

Detailed description

Advanced heart failure (HF) is characterized by persistent and progressive symptoms despite optimal, guideline-directed medical therapy. Although improvements in care have been achieved, mortality remains high, and recurrent hospitalizations continue to significantly impact patients' morbidity and quality of life. Timely recognition of early signs of clinical deterioration remains a challenge. Innovative approaches that enable early identification of patients at increased risk of readmission may support proactive interventions and help reduce the need for hospitalization. In the WAI-HF study, we will investigate whether AI-driven analysis wearable data can identify changes that precede hospital admission in patients with advanced heart failure. The wrist-worn device measures several physiological parameters including heart rate, heart rate variability, respiratory rate, skin temperature, 1-lead electrocardiogram, and sleep quality. Data collected in the remote monitoring including continuous data derived from the wearable device and symptomatic data collected in the eHealth app, will be used to develop a predictive model. The study will be conducted according to the principles of the Declaration of Helsinki (64th WMA General Assembly, Fortaleza, Brazil, October 2013), to 'gedragscode gezondheidsonderzoek', and in accordance with the EU GDPR (General Data Protection Regulation).

Interventions

None listed

Sponsors

Health Holland
CollaboratorOTHER
Viduet Health
CollaboratorUNKNOWN
UMC Utrecht
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* \>18 years. * Diagnosis of advanced heart failure, including at least one of the following major criteria. * LVAD implanted * Included on the waiting list for Heart transplant * Meeting the European Society of CArdiology criteria for advanced HF: * Severe and persistent symptoms of heart failure \[NYHA class III or IV\]. * Severe cardiac dysfunction: according to ESC guidelines definition * ≥ 1 unplanned visit or hospitalization in the last 12 months requiring IV treatment. * Have access to a mobile phone or tablet with an operating system iSO 15 or Android 9 (or posterior versions of these systems).

Exclusion criteria

* Impossibility to provide inform consent. * Impossibility to self-report data due to physical or mental disability.

Design outcomes

Primary

MeasureTime frameDescription
Algorithm Performance MetricsFrom enrollment to the end of the monitoring period at 1 year.Algorithm's performance to detect imminent admission in patients with advanced HF will be measured by means of the following parameters: Accuracy, sensitivity, specificity, negative predictive value, positive predictive value, area under the ROC curve.

Secondary

MeasureTime frameDescription
Change in daily exercise durationFrom baseline to the end of the monitoring period at 1 year.Daily exercise duration will be measured using the wrist worn-device. Exercise duration will be measured in minutes of activity per day and step count per day.
Perceived usabilityAt 1-yearPerceived usability will be assessed by means of The System Usability Scale (SUS). SUS is a widely used, validated tool for assessing the usability of a system, product, or technology. SUS is a 10-item questionnaire with statements about the system being evaluated. Each item is rated on a 5-point Likert scale (from Strongly Disagree \[1\] to Strongly Agree \[5\]). The single score ranges from 0 to 100 where higher scores indicate better usability.

Countries

Netherlands

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026