Skip to content

Validate the Efficacy and the Safety of the Keikku Electronic Stethoscope for Its Indication and Intended Purpose, Under the Intended Conditions of Use.

Prospective, Controlled, Open-label Study Evaluating the Keikku Electronic Stethoscope

Status
Recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT07044128
Acronym
KCI-1
Enrollment
149
Registered
2025-06-29
Start date
2025-07-15
Completion date
2025-10-15
Last updated
2025-06-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Heart Murmurs, Wheezing

Keywords

Stethoscopes, Heart Murmurs, Cardiac Auscultation, Diagnostic Techniques and Procedures, Medical Device Evaluation, Sound Recording and Reproduction, Pediatric Cardiology, Adult Cardiology, Telemedicine, Signal Processing, Computer-Assisted, Electronic Health Records, Clinical Accuracy, Safety Assessment, Prospective Studies

Brief summary

This study is testing a digital stethoscope called the Keikku electronic stethoscope. Doctors use stethoscopes to listen to the heart, and this new device records heart sounds using a smartphone app. The purpose of the study is to check how well this new device works and whether it is safe to use. The study will include 149 participants of all ages (from birth to 99 years), who are undergoing routine (non-urgent) heart checks. After giving consent, each participant will have their heart sounds listened to twice: once with the Keikku electronic stethoscope and once with a regular stethoscope. Two different doctors will do the listening, and they won't share information with each other. The doctors will record whether they hear a heart murmur and how clear the sounds were. The study will compare the findings from the new device to those from the regular stethoscope. Researchers will also check for any device problems or side effects. The study takes place at a single site in Peru and will take about one day for each participant. The goal is to find out if the Keikku electronic stethoscope is accurate and safe for doctors to use in real medical settings.

Detailed description

This clinical study is designed to evaluate the performance and safety of the Keikku electronic stethoscope, an innovative medical device developed by Lapsi Health Holding BV. The Keikku device combines a micro-electromechanical system (MEMS) sensor with a Bluetooth-enabled smartphone application, allowing physicians to capture and review heart sounds in real-time or via secure cloud storage. The Keikku electronic stethoscope differs from traditional stethoscopes in that it digitally records and transmits auscultation sounds without interpreting them. Physicians use the Keikku Mobile Application to listen, annotate, and share these sounds. This study assesses whether such a device can match the diagnostic capabilities of conventional analog stethoscopes, particularly in detecting heart murmurs. This is a prospective, open-label, controlled clinical investigation involving 149 pediatric and adult participants (from birth to age 99) in non-urgent cardiac evaluations. Each participant undergoes two sequential heart sound assessments at four standard precordial chest locations (mitral, tricuspid, aortic, and pulmonary): Keikku electronic stethoscope: used by a physician listening via Bluetooth headphones. Conventional stethoscope: used by a second, blinded physician. Each device's use is independently evaluated using predefined clinical report forms. Physicians record whether a murmur is present and rate the acoustic quality of the auscultation on a 5-point Likert scale. To ensure objectivity, physicians do not communicate their findings, and the second physician has no access to the recordings or results obtained by the first. All recordings (both digital and analog) are stored on GDPR-compliant cloud servers. Final clinical decisions about patient care are based only on the findings of the conventional stethoscope, not the investigational device. The study's primary endpoint is the agreement percentage between the Keikku and conventional stethoscopes in murmur detection. Secondary and exploratory endpoints include the incidence of device-related adverse events, the sensitivity and specificity of murmur detection, user-reported sound quality, and any technical issues (device deficiencies) encountered. Participation in this study lasts only one day and involves no follow-up visits. No treatment decisions are made based on the investigational device. The research is conducted at a single site in Peru, and the data will contribute to a broader understanding of digital stethoscope performance in clinical environments. By validating the diagnostic capabilities of the Keikku electronic stethoscope, this study aims to support the safe integration of digital auscultation technology into everyday clinical care and remote telemedicine applications.

Interventions

DEVICEDigital stethoscope using MEMS sensor and mobile application for cardiac auscultation

The intervention is a digital stethoscope system comprising a handheld device with a micro-electromechanical system (MEMS) sensor and a Bluetooth Low Energy (BLE) connection to a mobile application (Keikku Mobile App) installed on an iOS or Android smartphone. The device captures auscultation sounds from standard precordial locations (mitral, tricuspid, aortic, and pulmonary), transmits them in real time to the mobile application, and stores the recordings on a secure, GDPR-compliant cloud server. The device does not interpret sounds. Each auscultation lasts 15 seconds per site. Physicians use Bluetooth headphones to listen during recording. The application allows for annotation and review of sound data. The intervention is administered once per participant during a single study visit, immediately followed by a comparator auscultation using a conventional analog stethoscope by a second blinded physician.

Sponsors

Clínica Internacional
CollaboratorOTHER
Lapsi Health Holding B.V.
Lead SponsorINDUSTRY

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
No minimum to 99 Years
Healthy volunteers
Yes

Inclusion criteria

* Pediatric, including newborn (from birth to 1 month of age), or adult (aged 99 or below) individuals. * Individuals who are either: * presenting for initial, non-urgent outpatient evaluation of a cardiac murmur or for non-urgent cardiac clearance; or * presenting for return, non-urgent outpatient evaluation of a cardiac murmur; or * undergoing initial or recurrent, non-urgent evaluation of a cardiac murmur in inpatient setting; or * undergoing non-urgent cardiac clearance in inpatient setting.

Exclusion criteria

pregnant female individuals

Design outcomes

Primary

MeasureTime frameDescription
Agreement in murmur detection between digital and conventional stethoscopesDay 0 (Single visit)Overall agreement (in percent) between the Keikku electronic stethoscope and a conventional analog stethoscope in identifying the presence or absence of a heart murmur.

Countries

Peru

Contacts

Primary ContactAlfredo Gilberto Guerreros Benavides
alfgb@yahoo.es+51 1 6196161

Outcome results

None listed