Skip to content

Evaluation of the Performance of Glomerular Filtration Rate Measurement Using CT Urography in Patients With a GFR Below 60 mL/Min/1.73 m²

Evaluation of the Performance of Glomerular Filtration Rate Measurement Using CT Urography in Patients With Chronic Kidney Disease

Status
Not yet recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT07042698
Acronym
DUSIR
Enrollment
70
Registered
2025-06-29
Start date
2025-07-15
Completion date
2027-07-15
Last updated
2025-06-29

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Kidney Diseases, Tomography, X-Ray Computed

Keywords

Glomerular Filtration Rate, Tomography, X-Ray Computed

Brief summary

Glomerular filtration rate (GFR), which is the main biomarker used in clinical practice to assess kidney function, is usually estimated from the serum concentration of endogenous markers such as creatinine and/or cystatin C. GFR estimation equations all share the disadvantage of imperfect accuracy due to non-GFR-related determinants of creatinine and cystatin C. When knowing the exact GFR value is necessary for clinical decision-making, measurement by clearance of an exogenous tracer is required. Various tracers are available, some of which are radioactive tracers (99mTc-DTPA and 51Cr-EDTA), while others are iodinated contrast agents (iohexol, iothalamate). GFR measurement procedures are time-consuming and require significant human resources (4 to 5 hours, or even 24 hours for plasma clearances at very low GFR values).Urinary clearance methods may be inaccurate in cases of inadequate voiding. Plasma clearance results may be inaccurate in cases of increased (overestimation) or decreased (underestimation) extracellular volume, low GFR (unless late sampling is performed), or glomerular hyperfiltration. Measuring tracers requires either warm labs for measuring radioactive markers or labs with HPLC (High Performance Liquid Chromatography) chains for iohexol, which are part of an external quality assurance program. The complexity and/or length of GFR measurement procedures, their cost, and laboratory constraints explain why measured GFR is underused in routine clinical practice. There is a critical need to develop GFR measurement methods that are simpler to implement, reliable across the entire GFR spectrum, and widely available. We have demonstrated that it is possible to measure GFR using 4-phase CT urography performed as part of the care of living kidney donor candidates (healthy individuals with normal GFR). The examination takes 10 minutes, requires no biological sampling, and is not subject to potential inaccuracies due to sodium overload or poor bladder emptying.

Detailed description

Objective: To assess whether GFR measurement using 4-phase CT urography is reliable in patients with GFR below 60 ml/min/1.73 m², as compared with iohexol clearance (reference method): - Unbiased (mean difference between CT-measured GFR and iohexol clearance not different from zero). - and accurate: at least 50% and 80% of GFR values measured by CT urography within 10% and 20% of biological clearance values for iohexol clearance. Method: Single-center interventional study. After performing a 4-phase CT urography (or 3-phase CT scan, with the addition of a 4th phase for research purposes), performed for clinical indications as part of the patient's care, and using iohexol as a contrast agent, patients will undergo a biological measurement of iohexol clearance, based on serum and urine samples taken over 4 periods of 1 hour, between 3 and 7 hours after the CT scan. No iohexol will be reinjected to measure GFR. The CT scan images will be segmented by the investigator to determine the CT-measured GFR. The inclusion criteria are: - Patients older than 18 years of age - Having given written consent to participate in the study. - Patient referred to the medical imaging department of the Henri Mondor University Hospital for a 3-phase or 4-phase abdominal CT scan. - With an estimated GFR according to CKD-EPIcreat2009 \< 60 ml/min/1.73m² - Hospitalized or outpatient. - Affiliated with French national health insurance. The exclusion criteria are: - Patients with hip implants, due to artifacts that make quantification of the contrast agent in the bladder unreliable. - Lack of health insurance - Patients under legal protection.

Interventions

OTHERGlomerular Filtration Rate measurement with iohexol clearance

After performing a 4-phase CT urography (or 3-phase CT scan, with the addition of a 4th phase for research purposes), performed for clinical indications as part of the patient's care, and using iohexol as a contrast agent, patients will undergo a biological measurement of iohexol clearance, based on serum and urine samples taken over 4 periods of 1 hour, between 3 and 7 hours after the CT scan. No iohexol will be reinjected to measure GFR. The CT scan images will be segmented by the investigator to determine the CT-measured GFR.

Sponsors

Assistance Publique - Hôpitaux de Paris
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patients older than 18 years of age * Having given written consent to participate in the study * Patient referred to the medical imaging department of the Henri Mondor University Hospital for a 3-phase or 4-phase abdominal CT scan * With an estimated GFR according to CKD-EPIcreat2009 \< 60 ml/min/1.73m² * Hospitalized or outpatient * Affiliated with French national health insurance

Exclusion criteria

* Patients with hip implants, due to artifacts that make quantification of the contrast agent in the bladder unreliable * Lack of health insurance * Patients under legal protection.

Design outcomes

Primary

MeasureTime frameDescription
Assessment of the Reliability of GFR Measurement by 4-Phase CT Urography Compared to Iohexol ClearanceDay 1To assess whether GFR measurement using 4-phase CT urography is reliable in patients with GFR below 60 ml/min/1.73 m², as compared with iohexol clearance (reference method): - Unbiased (mean difference between CT-measured GFR and iohexol clearance not different from zero). - and accurate: at least 50% and 80% of GFR values measured by CT urography within 10% and 20% of biological clearance values for iohexol clearance.

Secondary

MeasureTime frameDescription
Reliability Assessment of GFR Estimation Using Creatinine and/or Cystatin C Compared to Iohexol ClearanceDay 1This outcome measure assesses the reliability of glomerular filtration rate (GFR) estimated from serum creatinine and/or cystatin C levels by comparing it to the biological measurement of iohexol clearance.
Reliability of Hybrid GFR (Mean of CT-Measured and Creatinine/Cystatin C Estimated GFR)Day 1This outcome measure evaluates the reliability of the hybrid GFR, defined as the average of the GFR measured by 4-phase CT urography and the GFR estimated from serum creatinine and cystatin C. The reliability will be compared to that of CT-measured GFR alone and creatinine/cystatin C-based estimated GFR,
Reliability of CT-Measured GFR Across Patient Subgroups Defined by Estimated GFR RangesDay 1This outcome measure assesses the reliability of GFR measured by 4-phase CT urography within different patient subgroups based on their estimated GFR values: between 45 and 60 ml/min/1.73m², between 30 and 44 ml/min/1.73m², and less than 30 ml/min/1.73m²

Countries

France

Contacts

Primary ContactThomas STEHLE, Dr
thomas.stehle@aphp.fr+33145178452

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026