Skip to content

Comparison of Different Pulsed Field Ablation Catheters in Atrial Fibrillation

Comparison of Different Pulsed Field Ablation Catheters Combined With Stroke Prevention in High Stroke Risk·Atrial Fibrillation: A Prospective, Multicenter, Randomized Controlled Trial

Status
Recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT07036965
Acronym
COMBINATION 2P
Enrollment
292
Registered
2025-06-25
Start date
2025-06-30
Completion date
2031-06-30
Last updated
2025-06-25

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Atrial Fibrillation (AF)

Keywords

atrial fibrillation, pulsed field ablation, LAAC

Brief summary

Pulsed field energy ablation, a non-thermal ablation modality, can potentially reduce post-ablation tissue edema. Previous studies have confirmed the feasibility and safety of combined pulsed field ablation (PFA) and left atrial appendage closure (LAAC) as a one-stop treatment, with few reports of post-ablation tissue edema. However, during PFA procedures, the presence of metallic components in the ablation site (e.g., occluder frames, metallic valves) may lead to arcing during energy delivery, compromising procedural safety. Therefore, when performing PFA+LAAC as a one-stop procedure, a ablation-first strategy is recommended. Due to the influence of parameters such as voltage, pulse width, and number of cycles on pulsed field energy characteristics, significant variability in ablation depth and area may exist between different PFA devices. To date, no large-scale clinical studies have compared the efficacy and safety of different PFA systems. Accordingly, this study will conduct a prospective, multicenter, randomized controlled trial to compare the effectiveness and safety of domestic versus imported pulsed field ablation catheters in the treatment of patients with atrial fibrillation.

Interventions

DEVICECardiPulse

abc

DEVICEFaraPulse

bcd

Sponsors

Hangzhou Dinova EP Technology Co., Ltd
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
118 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Older than 18 years. 2. Diagnosed with drug-refractory, symptomatic atrial fibrillation. 3. The patient has a high risk of stroke (CHA2DS2-VA score ≥ 2). 4. Have a situation of: 1. requires oral anticoagulation therapy 2. high bleeding risk (HAS-BLED score ≥ 3) that unsuitable for or unwilling to undergo long-term oral anticoagulation therapy. 5. Subjects are able to understand the purpose of the study, voluntarily participate in the study and sign the informed consent, and are willing to complete the follow-up according to the requirements of the program.

Exclusion criteria

1. History of persistent atrial fibrillation \>1 year. 2. Atrial fibrillation was secondary to thyroid disease or other reversible reasons. 3. Left atrial anteroposterior diameter \>50 mm. 4. Evidence of left atrial or left atrial appendage thrombus on imaging examination. 5. Concurrent other arrhythmias required for catheter ablation (e.g., atrioventricular reentrant tachycardia, atrioventricular nodal reentrant tachycardia, pre-excitation syndrome) prior to enrollment. 6. Rheumatic heart disease. 7. Left ventricular ejection fraction \<40% or New York Heart Association (NYHA) class III/IV. 8. Unstable angina. 9. Myocardial infarction (MI), coronary artery bypass grafting (CABG), or percutaneous coronary intervention (PCI) within 3 months prior to enrollment. 10. History of prior left atrial appendage closure, patent foramen ovale closure, atrial septal defect closure, or repair surgery. 11. Implantation of a mechanical mitral valve prosthesis or metallic annuloplasty rings. 12. Presence of intracardiac thrombus, space-occupying lesions, or other abnormalities that preclude vascular access or catheter manipulation. 13. Contraindications to anticoagulation or history of coagulation disorders/abnormal bleeding. 14. Active systemic infection. 15. Estimated glomerular filtration rate (eGFR) \<30 mL/min/1.73 m² or history of renal dialysis. 16. Pregnancy or breastfeeding. 17. Life expectancy \<12 months (e.g., advanced malignancy). 18. Current or anticipated participation in other drug or device clinical trials. 19. Any other condition or abnormality deemed by the investigator to warrant exclusion.

Design outcomes

Primary

MeasureTime frameDescription
12-month atrial fibrillation (AF) ablation success rate12 months post-procedureDefined as the absence of AF, atrial flutter (AFL), or atrial tachycardia (AT) episodes ≥30 seconds on dynamic electrocardiogram (ECG) monitoring after the blanking period (90 days post-catheter ablation)

Secondary

MeasureTime frameDescription
Incidence of major adverse events (MAEs) related to the deviceWithin 7 days post-procedureIncluding stroke/transient ischemic attack (TIA), pulmonary vein stenosis, phrenic nerve paralysis, systemic embolism, pericarditis, pericardial effusion/cardiac tamponade, atrioesophageal fistula, myocardial infarction, or severe vascular access complications
Incidence of repeat ablationWithin 12 months post-procedureSummary ncidence of repeat ablation after the blanking period
AF burden6 and 12 months post-procedureRecord AF burden at 6 and 12 months post-procedure
Incidence of cardiovascular MAEsWithin 12 months post-procedureIncidence of thromboembolic events (including stroke/TIA), cardiovascular-related rehospitalization, or cardiovascular mortality within 12 months post-procedure
Acute pulmonary vein ablation success rateImmediately post-procedureDefined as maintained bidirectional block across the ablation line 20 minutes after ablation
LAA closure rate3 and 6 months post-procedureDefined as imaging-confirmed residual shunt ≤3 mm at the device edges.
Incidence of new residual shunt3 and 6 months post-procedureDefined as any increase in residual shunt (post-procedure shunt volume - intraoperative shunt volume \>0 mm)
Incidence of device-related thrombusWithin 12 months post-procedure.Record device-related thrombus events during follow-up
Discontinuation rate of anticoagulants and antiarrhythmic medicationsWithin 12 months post-procedureRecord drugs history during follow up
Technical success rate of LAACImmediately post-procedureDefined as successful LAA occlusion without residual shunt \>3 mm and no device-related complications

Countries

China

Contacts

Primary ContactHuimin Chu, Dorctor
epnbheart@163.com+86 574-87085211

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026