Skip to content

Endovascular Repair With Fenestrated TREO Stent-Graft System in AAA

A Prospective, Multicenter, Non-Blinded, Non-Randomized Pivotal Study of the Fenestrated TREO Stent-Graft System in Subjects With Abdominal Aortic Aneurysms Requiring a Fenestrated Graft and Suitable for Endovascular Repair

Status
Recruiting
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT07026877
Enrollment
20
Registered
2025-06-18
Start date
2025-11-18
Completion date
2030-05-29
Last updated
2026-02-18

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Abdominal Aortic Aneurysms (AAA)

Keywords

Abdominal Aortic Aneurysm, juxtarenal, endovascular

Brief summary

The goal of this clinical trial is to learn if the Fenestrated TREO Stent-Graft System works to treat abdominal aneurysms in adults. An abdominal aneurysm is a bulge in the main blood vessel (the aorta) which carries blood from the heart, through the chest and abdomen. It will also learn about the safety of Fenestrated TREO Stent-Graft System. The main question it aims to answer is: Can the the Fenestrated TREO Stent-Graft System be used to treat participants with a specific type of abdominal aneurysm called a juxtarenal abdominal aortic aneurysm? Participants will: Have the the Fenestrated TREO Stent-Graft System implanted via an endovascular surgical procedure and visit the hospital for a follow up period of 5 years, for checkups, tests and imaging scans.

Interventions

DEVICEFenestrated TREO Stent Graft System

The Fenestrated TREO Stent-Graft System is a modular, endoluminal, over-the-wire system intended for the endovascular treatment of juxtarenal and pararenal to paravisceral aneurysms requiring a fenestrated stent-graft and having suitable morphology. The system is composed of the following components: Fenestrated TREO Bifurcate Stent-Graft - The main body fenestrated bifurcate provides the following; proximal seal, fenestrations and gates for connection to the leg extensions. Bridging Stents - The bridging stent connects the main body bifurcated device to the target visceral artery allowing the target anatomy to maintain perfusion while keeping the pathology sealed TREO Leg and Straight Extension Stent-Grafts: The Leg Extension and Straight Extension stent-grafts are used to complete coverage of the pathology from the main body bifurcated device to the distal landing zones (usually the common iliac artery just proximal to the iliac bifurcation).

Sponsors

Bolton Medical
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* 18 years or older at the time of consent * Life expectancy is greater than 2 years * An abdominal aortic or aorto-iliac aneurysm requiring a fenestrated graft and with morphology suitable for endovascular repair (confirmed by Computed Tomography (CT) with contrast performed within 6 months of planned implant procedure) as follows: 1. Maximum aneurysm diameter of ≥5.5 cm for male ( ≥5.0 cm for female) or 2. Maximum AAA diameter exceeding two times the normal diameter just proximal to the aneurysm using orthogonal (i.e., perpendicular to the centerline) measurements (or saccular aneurysm that warrants treatment in the opinion of the investigator) or 3. Aneurysm with a history of growth \> 0.5 cm in 6 months and 4. Minimum 0 mm of healthy aorta\* below the most inferior renal artery that the physician plans on preserving and no renal artery involvement (juxtarenal aneurysms) or 5. At least one renal artery involved in the aneurysm and minimum 2 mm below the celiac (suprarenal aneurysms) \*Healthy aorta is defined as segment of aorta with parallel aortic wall with minimal (\<10%) or no difference in diameter and minimal atherosclerotic debris, thrombus, or calcification. * Proximal landing zone: 1. ≥20 mm length 2. 20-32 mm diameter 3. ≤60° angle relative to the axis of the suprarenal aorta 4. ≤60° angle relative to the long axis of the aneurysm * Distal (iliac) landing zone with: 1. 8-13 mm inside diameter/ ≥10 mm length 2. \>13-20 mm inside diameter/ ≥15 mm length * Distal aortic diameter (above the iliac bifurcation) ≥70% of the sum of the iliac limb graft diameters * Minimum 18 mm aortic lumen diameter at the level of the fenestrations * Pathology that requires maximum 5 fenestrations in the main body * Pathology that requires fenestration a minimum 3 mm apart (edge to edge) * Branch vessels (to be bridged to the fenestrated graft) with: 1. 5-9 mm diameters 2. ≥13 mm distal landing zone (or ≥15 mm if there is a gap between fenestration and target vessel) * Adequate renal function to tolerate contrast-enhanced CTA * Adequate vascular access compatible with required delivery systems * Willingness to comply with the follow-up evaluation schedule documented in a signed informed consent prior to implant

Exclusion criteria

* Pregnant or lactating * Existing endovascular graft in the treated segment intended to be repaired with the Fenestrated TREO Stent-Graft System * Dissection in abdominal aorta, ruptured aneurysm, or symptomatic aneurysm (as determined by treating physician) * Implant procedure as planned does not allow for at least one patent hypogastric artery left intact, unless both are occluded on pre-op imaging. * A branch vessel(s) that is dissected or has significant calcification, tortuosity, thrombus formation that would interfere with bridging stent delivery or sealing (as determined by treating physician) * Severe untreated coronary artery disease and/or unstable angina, significant areas of myocardium at risk (based on coronary angiogram or radionuclide scans), left ventricular ejection fraction \<20%, or recent diagnosis of congestive heart failure (CHF; as determined by treating physician). * Stroke or myocardial infarction within 6 months of the planned treatment date * Chronic obstructive pulmonary disease requiring routine need for oxygen therapy outside the hospital setting (e.g., daily or nightly home use) * Chronic Kidney Disease (CKD) stage ≥3b.\* \* During Stage 2, patients with severe CKD (stage ≥3b) can be included in the Expanded Access Arm if otherwise eligible. * Active systemic infection or is suspected of having an active systemic infection (e.g., acquired immune deficiency syndrome (AIDS)/human immunodeficiency virus (HIV), sepsis) * Clinical conditions that would severely compromise or impair x-ray visualization of the aorta (as determined by treating physician). * History of an aortopathic connective tissue disease (e.g., Marfan's syndrome) * Mycotic aneurysm * Significant or circumferential calcification or mural thrombus (as determined by treating physician): 1. in the proximal aortic neck 2. in the distal iliac landing zone 3. within the treatment length, which may adversely impact device patency * Cannot receive intraprocedural anticoagulation per the investigator's standard of care, or antiplatelet therapy post-procedurally as per the investigator's standard of care. * Blood coagulation disorder or bleeding diathesis, the treatment for which cannot be suspended pre- and post-repair * An investigational study drug or biologic within 30 days of planned procedure or an investigational device within one year of planned procedure or any other treatment that may interfere with the interpretation of the study results. * Medical, social or psychological issues that the investigator believes may interfere with study treatment or follow-up. * Untreatable allergy or sensitivity to contrast media, nitinol/nickel, Tantalum, Platinum Iridium (PtIr), 316 stainless steel, ePTFE (expanded polytetrafluoroethylene), PTFE (polytetrafluoroethylene) Impregnated polyester fiber, or polyester * Other major surgical or medical intervention within 45 days of the planned procedure or plan to undergo other major surgical or medical intervention within 45 days post implantation (e.g., coronary artery bypass graft (CABG), organ transplantation, renal stenting)

Design outcomes

Primary

MeasureTime frameDescription
Proportion of patients with absence of a major adverse event (Primary Safety Endpoint)30-day post-procedureThe primary safety endpoint is the absence of a major adverse event (MAE) at 30-day post procedure. MAEs are defined as follows: * All-cause mortality, defined as death due to any cause * Myocardial infarction (new onset) based on the Society for Cardiovascular Angiography \& Interventions (SCAI) definition * Respiratory failure requiring prolonged (\>24 hours from anticipated) mechanical ventilation or reintubation * Renal function decline resulting in \>50% reduction from baseline estimated glomerular filtration rate (eGFR) or new-onset dialysis * Bowel ischemia requiring surgical resection or not resolving with medical therapy * Disabling stroke (modified Rankin Scale (mRS) score ≥2 at 90 days post event and an increase in ≥1 mRS category from an individual's pre-stroke baseline, as direct result of the neurological event) * Paraplegia (grade 3, Society for Vascular Surgery (SVS) Thoracic Endovascular Aortic Repair (TEVAR) guidelines)
Proportion of patients with successful aneurysm treatment through 12-months post-implant procedure (Primary Effectiveness Endpoint)12 months post-procedureThe primary effectiveness endpoint is the proportion of patients with successful aneurysm treatment through 12-months post-implant procedure, which is a composite of technical success and absence of the following: * Aneurysm-related mortality: Death occurs within the first 30-days of the index procedure or a secondary intervention, OR any death that results from aneurysm rupture or an aorta-related complication (e.g., implant infection, occlusion, dissection) * Aneurysm rupture: Rupture of the native aneurysm sac (treated lesion) * Type I/III Endoleak * Aneurysm Expansion (\>5 mm) * Migration (\>10 mm) * Loss of patency (i.e., complete occlusion of the aortic implant and/or bridging stent(s)) * Conversion to open surgical repair: Explant of the investigational device due to any cause * Secondary intervention (clinically significant) to address loss of patency, fixation or seal
Successful delivery and deployment of the aortic stent-graft and all modular stent-graft components (Technical Success)Evaluated 30-days post procedureComposite: * Successful access to the arterial system using remote arterial exposure, percutaneous technique, or open surgical conduit without the need for unanticipated corrective intervention related to access * Successful delivery and deployment of the aortic stent-graft and all modular stent-graft components without the need for unanticipated corrective intervention related to delivery and deployment * Successful side branch catheterization and placement of bridging stents with restoration and maintenance of flow in all intended target vessels without the need for unanticipated corrective intervention related to placement of the bridging stent(s) * Successful withdrawal of the delivery systems without the need for unanticipated corrective intervention related to withdrawal * Absence of Type I or III endoleaks (assessed by Computed Tomography Angiography, Magnetic Resonance Angiography, or duplex ultrasound) * Patency of all aortic modular stent graft components

Secondary

MeasureTime frameDescription
Respiratory failureEvaluated at all follow up visits which occur at the following timepoints: at discharge, 30 days post-procedure, six months post-procedure, 12-months post-procedure and annually thereafter through to five years post-procedure.Individual component of the primary safety endpoint - respiratory failure requiring prolonged (\>24 hours from anticipated) mechanical ventilation or reintubation
Renal function declineEvaluated at all follow up visits which occur at the following timepoints: at discharge, 30 days post-procedure, six months post-procedure, 12-months post-procedure and annually thereafter through to five years post-procedure.Individual component of the primary safety endpoint - Renal function decline resulting in \>50% reduction from baseline eGFR or new-onset dialysis
Bowel ischemiaEvaluated at all follow up visits which occur at the following timepoints: at discharge, 30 days post-procedure, six months post-procedure, 12-months post-procedure and annually thereafter through to five years post-procedure.Individual component of the primary safety endpoint - Bowel ischemia requiring surgical resection or not resolving with medical therapy
Disabling strokeEvaluated at all follow up visits which occur at the following timepoints: at discharge, 30 days post-procedure, six months post-procedure, 12-months post-procedure and annually thereafter through to five years post-procedure.Individual component of the primary safety endpoint - Disabling stroke (mRS score ≥2 at 90 days post event and an increase in ≥1 mRS category from an individual's pre-stroke baseline, as direct result of the neurological event)
ParaplegiaEvaluated at all follow up visits which occur at the following timepoints: at discharge, 30 days post-procedure, six months post-procedure, 12-months post-procedure and annually thereafter through to five years post-procedure.Individual component of the primary safety endpoint -Paraplegia grade 3, as per SVS TEVAR guidelines
Aneurysm-related mortalityEvaluated at all follow up visits which occur at the following timepoints: at discharge, 30 days post-procedure, six months post-procedure, 12-months post-procedure and annually thereafter through to five years post-procedure.Individual components of the primary effectiveness endpoint - defined as death which occurs within the first 30-days of the index procedure or a secondary intervention, OR any death that results from aneurysm rupture or an aorta-related complication (e.g., implant infection, occlusion, dissection)
Aneurysm ruptureEvaluated at all follow up visits which occur at the following timepoints: at discharge, 30 days post-procedure, six months post-procedure, 12-months post-procedure and annually thereafter through to five years post-procedure.Individual components of the primary effectiveness endpoint - Rupture of the native aneurysm sac (treated lesion)
Type I/III EndoleakEvaluated at all follow up visits which occur at the following timepoints: at discharge, 30 days post-procedure, six months post-procedure, 12-months post-procedure and annually thereafter through to five years post-procedure.Individual components of the primary effectiveness endpoint - Presence of Type I/IIIEndoleak as confirmed by imaging
Aneurysm ExpansionEvaluated at all follow up visits which occur at the following timepoints: at discharge, 30 days post-procedure, six months post-procedure, 12-months post-procedure and annually thereafter through to five years post-procedure.Individual components of the primary effectiveness endpoint - Aneurysm expansion (\>5 mm)
Device MigrationEvaluated at all follow up visits which occur at the following timepoints: at discharge, 30 days post-procedure, six months post-procedure, 12-months post-procedure and annually thereafter through to five years post-procedure.Individual components of the primary effectiveness endpoint - Device migration (\>10mm)
Loss of device patencyEvaluated at all follow up visits which occur at the following timepoints: at discharge, 30 days post-procedure, six months post-procedure, 12-months post-procedure and annually thereafter through to five years post-procedure.Individual components of the primary effectiveness endpoint - complete occlusion of the aortic implant and/or bridging stent(s)
Conversion to open surgical repairEvaluated at all follow up visits which occur at the following timepoints: at discharge, 30 days post-procedure, six months post-procedure, 12-months post-procedure and annually thereafter through to five years post-procedure.Individual components of the primary effectiveness endpoint - Explant of the investigational device due to any cause
Secondary intervention (clinically significant) to address loss of patency, fixation or sealEvaluated at all follow up visits which occur at the following timepoints: at discharge, 30 days post-procedure, six months post-procedure, 12-months post-procedure and annually thereafter through to five years post-procedure.Individual components of the primary effectiveness endpoint. This includes the following reasons for re-intervention: Loss of Patency: Complete occlusion of the aortic endovascular graft, bridging stent(s), and/or limb(s) Seal: Type Ia/Ib, IIIa/IIIb/IIIc Endoleaks Fixation: Fracture, Kink, Migration Device System Prophylaxis: Device-related Reintervention requiring hospitalization Minor Secondary Interventions will not count against the endpoint and include the following: Endovascular procedures (completed for any reason), specifically percutaneous transluminal angioplasty, atherectomy, stenting without thrombectomy or thrombolysis Interventions to address branch vessel stenosis Interventions to address Type II endoleaks Minor surgical revisions (e.g., patch angioplasty) of the access vessel
Technical Success (at the index procedure)At time of index procedureTechnical Success (at the index procedure) is a composite of the following: * Successful access to the arterial system using remote arterial exposure, percutaneous technique, or open surgical conduit without the need for unanticipated corrective intervention related to access. * Successful delivery and deployment of the aortic stent-graft and all modular stent-graft components without the need for unanticipated corrective intervention related to delivery and deployment. * Successful side branch catheterization and placement of bridging stents with restoration and maintenance of flow in all intended target vessels without the need for unanticipated corrective intervention related to placement of the bridging stent(s) * Successful withdrawal of the delivery systems without the need for unanticipated corrective intervention related to withdrawal.
Presence of endoleakEvaluated at all follow up visits which occur at the following timepoints: at discharge, 30 days post-procedure, six months post-procedure, 12-months post-procedure and annually thereafter through to five years post-procedure.Evaluation of the presence of all endoleak types, as confirmed by imaging
Aneurysm size changesEvaluated at all follow up visits which occur at the following timepoints: at discharge, 30 days post-procedure, six months post-procedure, 12-months post-procedure and annually thereafter through to five years post-procedure.Evaluation of changes in aneurysm size. Enlargement is defined as \>5mm, regression is ≥ 5 mm.
Device Migration EvaluationEvaluated at all follow up visits which occur at the following timepoints: at discharge, 30 days post-procedure, six months post-procedure, 12-months post-procedure and annually thereafter through to five years post-procedure.Evaluation of device migration. Migration is defined as \>10mm.
Patency related observationsEvaluated at all follow up visits which occur at the following timepoints: at discharge, 30 days post-procedure, six months post-procedure, 12-months post-procedure and annually thereafter through to five years post-procedure.Stenosis and occlusion of the components of the Fenestrated TREO Stent-Graft System
Loss of device integrityEvaluated at all follow up visits which occur at the following timepoints: at discharge, 30 days post-procedure, six months post-procedure, 12-months post-procedure and annually thereafter through to five years post-procedure.Fracture of stent strut, barb, or fenestration ring in Fenestrated TREO, fracture of stent in any Fenestrated TREO system implant
Target vessel instabilityEvaluated at all follow up visits which occur at the following timepoints: at discharge, 30 days post-procedure, six months post-procedure, 12-months post-procedure and annually thereafter through to five years post-procedure.Target vessel instability is a composite endpoint consisting of the following side branch complications: * Death related to side branch complication(s) * Rupture related to side branch complication(s) * Secondary intervention to address a side branch-related complication
Secondary interventions related to the device/treated lesionEvaluated at all follow up visits which occur at the following timepoints: at discharge, 30 days post-procedure, six months post-procedure, 12-months post-procedure and annually thereafter through to five years post-procedure.Any secondary interventions that are performed that are related to the device or the treated lesion will be recorded.
Target vessel complicationsEvaluated at all follow up visits which occur at the following timepoints: at discharge, 30 days post-procedure, six months post-procedure, 12-months post-procedure and annually thereafter through to five years post-procedure.Including dissection and/or perforation
Access-related complicationsEvaluated at all follow up visits which occur at the following timepoints: at discharge, 30 days post-procedure, six months post-procedure, 12-months post-procedure and annually thereafter through to five years post-procedure.Access-related complications
Serious Adverse EventsEvaluated at all follow up visits which occur at the following timepoints: at discharge, 30 days post-procedure, six months post-procedure, 12-months post-procedure and annually thereafter through to five years post-procedure.As per protocol definition
Operative metrics - Number of Vessels intended to be Perfused via Fenestrated TREO FenestrationsEvaluated at time of implantInformation relating to the number and name of the vessels to be perfused via the Fenestrated TREO Fenestrations
Operative metrics - Mechanism of accessEvaluated at time of implantInformation relating to the mechanism of access for the endovascular procedure
Radiation Exposure - Fluoroscopy TimeEvaluated at time of implantFluoroscopy time (min)
Operative metrics - TimePerioperativeInformation relating to the time of the surgical procedure such as start time, stop time, duration of procedure (min) and length of endovascular time (min)
Radiation Exposure - Total volume of ContrastEvaluated at time of implantVolume of contrast used during procedure measured in mL
All-Cause MortalityEvaluated at all follow up visits which occur at the following timepoints: at discharge, 30 days post-procedure, six months post-procedure, 12-months post-procedure and annually thereafter through to five years post-procedure.Individual component of the primary safety endpoint - defined as death due to any cause
Myocardial Infarction (new onset)Evaluated at all follow up visits which occur at the following timepoints: at discharge, 30 days post-procedure, six months post-procedure, 12-months post-procedure and annually thereafter through to five years post-procedure.Individual component of the primary safety endpoint - based on the SCAI definition

Countries

United States

Contacts

CONTACTLauren Rider
L.rider@terumoaortic.com19545470374
CONTACTValerie Merkle
v.merkle@terumoaortic.com+1 954 838 9699
PRINCIPAL_INVESTIGATORBenjamin W Starnes, MD

University of Washington

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 19, 2026