Skip to content

ROSA® Knee System V1.5 Pilot Study

A Single-arm, Monocentric, Cross-sectional, Pilot Study Evaluating Updated Features for The ROSA® Knee System, v1.5, in Patients Undergoing Primary Total Knee Arthroplasty

Status
Completed
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT07009912
Enrollment
40
Registered
2025-06-08
Start date
2025-02-25
Completion date
2026-02-17
Last updated
2026-02-27

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Joint Diseases, Knee Arthroplasty, Total, Knee Osteoarthritis, Robotic Surgical Procedures

Brief summary

This pilot study seeks to evaluate the initial safety and usability of new features for the ROSA® Knee System, v1.5 and plan design modifications as needed. The primary objectives will be assessed by measuring: 1. Intra-operative complications 2. Verification that the device performs as intended 3. Overall surgeon satisfaction with the instrumentation.

Detailed description

This study will involve single-arm, monocentric, cross-sectional observations conducted on the day of surgery. All assessments will take place during the pre-operative, intra-operative, and immediate postop periods on the day of surgery, with no additional follow-up beyond the procedure as robotic-assisted surgery using the current version of the robot is part of routine practice. The safety of the system is the primary endpoint. This will be assessed by monitoring the frequency and incidence of adverse events. Relation of the events to implant, instrumentation and/or procedure should be specified. The secondary endpoint is defined by the usability of Zimmer Biomet ROSA® Knee System, v1.5. It will be assessed by: 1. Robotic log files to assess differences in the proposed plans by the system's new features and plan approved by the surgeon, along with time spent in the planning panel. 2. Surgeon satisfaction with the new features.

Interventions

DEVICETotal Knee Arthroplasty

Robotic-assisted primary total knee arthroplasty, evaluating updated features for the Zimmer Biomet ROSA® Knee System, v1.5.

Sponsors

Zimmer Biomet
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
OTHER
Masking
NONE

Intervention model description

Single-arm, monocentric, cross-sectional, pilot study

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Patient is a minimum of 18 years of age * Independent of study participation, patient is a candidate for primary total knee arthroplasty using commercially available and compatible implants in accordance with product labeling * Patient is willing and able to provide written Informed Consent by signing and dating the EC approved Informed Consent form

Exclusion criteria

* Patient is currently participating in any other surgical intervention studies or pain management studies * Patient is pregnant or considered a member of a protected population (e.g., prisoner, mentally incompetent, etc.) * Patient has previously received partial or total knee arthroplasty for the ipsilateral knee

Design outcomes

Primary

MeasureTime frameDescription
Incidence of Procedure-Emergent Adverse Events, to assess the Safety of the ROSA® Knee System v1.5 SystemIntra-operative observations, with immediate post-operative documentation and reporting period.The safety of the system will be assessed by monitoring the frequency and incidence of adverse events. This will occur through the reporting of adverse events that outline the details and relationship to: 1. Device 2. Procedure 3. Instruments 4. Cement in order to determine device-related or non-device-related complications that occur during the procedure. Thus the incidence of procedure-emergent adverse events will notify and quantify the safety of the features added to the subject device (ROSA® Knee System v1.5 System)

Secondary

MeasureTime frameDescription
Verification and Usability of the OptimiZe Planning and Activ Track Investigational Features of the ROSA® Knee System v1.5 SystemIntra-operative evaluation, with immediate post-operative assessment and documentation. Data and statistical analysis will take place after the recruitment period has concluded.Robotic log files will be evaluated to assess the following: a) The delta between the OptimiZe proposed plan and the final plan approved by the surgeon, planned and final laxities, planned and final resections thus allowing for conclusions to be drawn from objective datapoints on the verification of the OptimiZe planning feature, and its validation to execute the proposed plan. Additionally, surgeon satisfaction with the features will be evaluated with the following questionnaire (Case Report Form), to determine usability: 1. Were you able to perform tracker calibration? 2. Were you able to complete painting? 3. Were you able to perform the contact point step? 4. Overall, how satisfied are you with the usability of OptimiZe to assist with planning? 5. Overall, how satisfied are you with the usability of Activ Track to complete the resections? 6. How likely are you to recommend The ROSA Knee System v1.5 application to a peer? Q1-4 are yes/no, Q5-6 are subjective scales with 5 answers.

Countries

New Zealand

Outcome results

None listed