Skip to content

Study of Human Ocular Hemodynamics by Holography Dopple

Study of Human Ocular Hemodynamics by Holography Dopple

Status
Not yet recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06989996
Acronym
HoLoEye
Enrollment
148
Registered
2025-05-25
Start date
2025-06-30
Completion date
2028-06-30
Last updated
2025-05-25

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Glaucoma, Retinal Vascular Disorder

Keywords

glaucoma, pachychoroid,, carotid stenosis

Brief summary

Prospective, interventional, non-randomized, open-label study, multi-center, Gehan-designed study with sequential inclusions in each subgroup, ranging from 4 subjects to a maximum 37 subjects per subgroup included

Detailed description

Retinal perfusion can be affected by a number of local or general pathologies; however, there is currently no commercially available device to provide accurate measurements of retinal blood flow. The company Quantel Medical is developing a medical imaging device HoloDoppler (hereinafter referred to as the HoloDoppler system). system. In order to better define its medical utility, we aim to evaluate its reproducibility and accuracy in healthy subjects and those with conditions that may affect ocular blood flow.

Interventions

DEVICEImages Acquisition

Acquisition of useable video images

Sponsors

Centre Hospitalier National d'Ophtalmologie des Quinze-Vingts
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
PARALLEL
Primary purpose
OTHER
Masking
NONE

Intervention model description

* Patients wirhs ocular disease: patients with glaucoma and patients with choroidal disease * Participants without ocular disease: healthy volunteers and patients with carotid stenosis

Eligibility

Sex/Gender
ALL
Age
18 Years to 74 Years
Healthy volunteers
Yes

Inclusion criteria

Criteria common to both populations ( patients and healthy volunteers) : * Age ≥ 18 years and \< 75 years; * Having received informed information about the study and having signed a consent to participate in the study; * Affiliated or covered by social security Criteria for healthy volunteers : No ocular or systemic disease deemed to affect ocular circulation by an investigator Specific criteria for patients: * Subjects usually followed at one of the recruiting centers; * Patients with chronic glaucoma, for whom a therapeutic modification is planned in the short term; * Patients with carotid stenosis; * Patients with choroidal pathology: pachychoroidism having led to pigment epithelium anomalies.

Exclusion criteria

* For all participants: * Persons covered by articles L1121-5 to L1121-8 of the CSP (all protected persons: pregnant women, parturients, nursing mothers, persons deprived of their liberty by judicial decision or administrative decision, minors, and persons under legal protection: guardianship or curatorship); * Women of childbearing age not using an effective method of contraception, or positive pregnancy test (blood or urine); * Participants allergic to tropicamide when using pupillary dilatation; * Inability of the subject to maintain a stable sitting position for research procedures; * Temporary contraindication to HoloDoppler: * Patient suffering from viral conjunctivitis or any other infectious disease; * Patient with skin lesions on the neck or forehead, for which contact with a chin strap is not recommended. * Impossibility of making acquisitions of interest (e.g. due to a pupil diameter that is too small, advanced cataracts, nystagmus, etc.). * Wearing glasses or contact lenses to correct a refractive disorder is not considered a criterion for non-inclusion.

Design outcomes

Primary

MeasureTime frameDescription
Feasibility of blood flow monitoring15 minutesEvaluate the feasibility of retinal blood flow measurement with HoloDoppler imaging
Assessment of the reproducibility of blood flow measurements15 minutesDetermine the reproducibility of retinal blood flow measurements with holodoppler at 15 minutes with the same operator and two different operators This is an evaluation of image quality in terms of operation according to the following scheme. Quality assessment: \- Sufficient quality : Yes Or No If no, tick yes, below and fill in the cause: Insufficient quality: ☒ yes ☐ no Cause: * Technical problem Or * Patient-related problem (inability to fix, or comply with procedure, etc.).
statistical precision measurements by intra-class coefficient (ICC)15 minutesevaluate the accuracy of measurements or assessments by different operators the HoloDoppler system

Contacts

Primary ContactNabil BROUK
nbrouk@15-20.fr00 33 1 40 02 11 44

Outcome results

None listed