Skip to content

A Study on the Safety and Effectiveness of the Mantra™ Surgical Robotic System for Soft Tissue Surgeries

A Real-World, Multicenter, Retrospective Study to Evaluate the Clinical Performance and Safety of MantraTM Surgical Robotic System for Soft Tissue Surgeries

Status
Not yet recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT06974955
Acronym
MARS
Enrollment
365
Registered
2025-05-16
Start date
2025-05-31
Completion date
2025-11-30
Last updated
2025-05-16

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Soft Tissue Surgeries

Keywords

Retrospective Study, Real World, Mantra TM Surgical Robotic System, soft tissue surgeries

Brief summary

A Real-World, multicentre retrospective study to evaluate the clinical performance and safety of MantraTM Surgical Robotic System for soft tissue surgeries. The purpose of this retrospective study is to evaluate the clinical performance and safety of the Mantra™ Surgical Robotic System, Model 3.0, for soft tissue surgeries. It aims to provide real-world evidence on the system's reliability, safety, and effectiveness in the real world population. The SSI Mantra 3.0 Surgical Robotic System is an advanced, modular, and cost-effective robotic-assisted surgical platform designed to enhance precision, flexibility, and control in minimally invasive surgeries (MIS). The objective of this retrospective study is to assess the clinical performance and safety of the Mantra™ Surgical Robotic System in performing various soft tissue surgeries based on retrospective data analysis.

Detailed description

A Real-World, multicentre retrospective study to evaluate the clinical performance and safety of MantraTM Surgical Robotic System for soft tissue surgeries. Objective : To assess the clinical performance and safety of the Mantra™ Surgical Robotic System in performing various soft tissue surgeries based on retrospective data analysis. Study Outcomes: The retrospective analysis of the Mantra Surgical Robotic System focused on evaluating its clinical performance, safety and efficacy in minimally invasive surgeries. The study outcomes were assessed based on surgical safety and efficacy parameters, intraoperative efficiency, post-operative recovery, and system utilization trends. Primary Study Outcomes 1. Primary Effectiveness Endpoint * Rate of Unplanned Conversion to other minimally invasive surgery (MAS) or open surgery (OP). * Successful completion of the procedure using the SSI Mantra 3.0 Surgical Robotic System as planned. 2. Primary Safety Endpoint * Rate of Total Intraoperative and Postoperative Serious Adverse Events (SAE) up to 30 days post-procedure. * Assessment of device-related complications . Secondary Study Outcomes 1\. Operative Time * Measured from skin incision to skin closure to assess efficiency. 2. Estimated Blood Loss (Intraoperative) * Quantification of blood loss during surgery. 3. Need for Blood Transfusion * Evaluation of cases requiring intraoperative blood transfusion. 4. Intraoperative Complications * Identification and classification of adverse events occurring during surgery. 5. Return to Operating Room within 24 Hours * Evaluation of unplanned reoperations. 6. Length of Hospital Stay * Time from hospital admission to discharge post-surgery. 7. Readmission to Hospital within 30 Days * Tracking of unexpected hospital readmissions. 8. Reoperation within 30 Days * Incidence of repeat surgical interventions. 9. Mortality Rate at 30 Days * Evaluation of patient survival post-procedure. 10. Device Deficiencies and Use Errors * Documentation of device-related malfunctions or improper usage. 11. All Adverse Events * Comprehensive assessment of both minor and major adverse effects. 12. Device Performance Data * Monitoring of unplanned instrument usage, system clashes, collision detection, and alarm activations. Timepoints: Day of surgery - 30 days (follow-up). Study Design: This is a retrospective, multicentre study designed to collect and analyze data from surgeries performed using the Mantra™ Surgical Robotic System, Models 3.0,. The study will evaluate clinical performance, safety, and patient outcomes across approximately twenty centers with a target sample size of 365 patients.

Interventions

None listed

Sponsors

Clicebo Solutions Private Limited
CollaboratorOTHER
Sudhir Srivastava Innovations Pvt. Ltd.
Lead SponsorINDUSTRY

Study design

Observational model
COHORT
Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

\- Participants must meet all of the following criteria to be eligible for inclusion in this retrospective clinical study of the SSI Mantra 3.0 Surgical Robotic System. Patients who have previously undergone surgery using the Mantra™ Surgical Robotic System (Model 3.0) for the following procedures mentioned in Appendix D

Exclusion criteria

* Patients with missing data on primary endpoints.

Design outcomes

Primary

MeasureTime frameDescription
Rate of Unplanned Conversion to other minimally invasive surgery (MAS) or open surgery (OP)1 day• Rate of Unplanned Conversion to other minimally invasive surgery (MAS) or open surgery (OP).
Successful completion of procedures without the need for conversion1 daySuccessful completion of procedures without the need for conversion
Rate of intraoperative and postoperative serious adverse events (SAEs) occurring up to 30 days post-procedure30 daysRate of intraoperative and postoperative serious adverse events (SAEs) occurring up to 30 days post-procedure
Evaluation of surgical complications, including infections, haemorrhage, and device-related adverse events30 dayEvaluation of surgical complications, including infections, haemorrhage, and device-related adverse events

Secondary

MeasureTime frameDescription
Intraoperative Complications - Identification and classification of adverse events occurring during surgery1 dayIdentification and classification of adverse events occurring during surgery
Return to Operating Room within 24 Hours - Evaluation of unplanned reoperations1 dayEvaluation of unplanned reoperations
Length of Hospital Stay - Time from hospital admission to discharge post-surgery30 daysTime from hospital admission to discharge post-surgery
Reoperation within 30 Days - Incidence of repeat surgical interventions30 daysIncidence of repeat surgical interventions
Readmission to Hospital within 30 Days - Tracking of unexpected hospital readmissions30 daysTracking of unexpected hospital readmissions
Device Deficiencies and Use Errors - Documentation of device-related malfunctions or improper usage1 dayDocumentation of device-related malfunctions or improper usage
All Adverse Events - Monitoring of all minor and major adverse events related to surgery30 daysMonitoring of all minor and major adverse events related to surgery
Device Performance Metrics - Assessment of unplanned instrument usage, robotic arm clashes, collision detection, and system-generated alarms1 dayAssessment of unplanned instrument usage, robotic arm clashes, collision detection, and system-generated alarms
Mortality Rate at 30 Days - Evaluation of patient survival post-procedure30 daysEvaluation of patient survival post-procedure
Operative Time - Measured from skin incision to skin closure to assess efficiency1 dayMeasured from skin incision to skin closure to assess efficiency
Estimated Blood Loss (Intraoperative) - Quantification of Blood loss during surgery1 dayQuantification of blood loss during surgery
Need for Blood Transfusion - Evaluation of cases requiring intraoperative blood transfusion1 dayEvaluation of cases requiring intraoperative blood transfusion

Countries

India

Contacts

Primary ContactSonia Shokeen
Sonia.shokeen@ssinnovations.org91+9958002162
Backup ContactPriyadarshini Arambam
regulatory@clicebo.com91+9910990347

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026