Evaluation of Daily Disposable Toric Soft Lenses Manufactured With an Alternative Hydration Process

Evaluation of Daily Disposable Toric Soft Lenses Manufactured With an Alternative Hydration Process

Status
Completed
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06967129
Enrollment
281
Registered
2025-05-13
Start date
2025-04-25
Completion date
2025-07-14
Last updated
2026-09-15

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Astigmatism

Brief summary

This is a prospective, multi-site, dispensing, randomized, controlled, double-masked, bilateral wear, 2x2 crossover study to evaluate the safety and effectiveness of the test lens.

Interventions

DEVICEInvestigational daily disposable, soft, toric lenses manufactured on 4th Generation Technology (4GT) lines with extended mini-stack hydration using propylene glycol (PG) as the hydration solvent.

Test Lens

DEVICEACUVUE® Oasys 1-Day for Astigmatism (AO1DfA) soft contact lenses manufactured on 3rd Generation Technology (3GT) legacy lines using isopropyl alcohol (IPA) as the hydration solvent.

Control Lens

Sponsors

Johnson & Johnson Vision Care, Inc.
Lead SponsorINDUSTRY

Study design

Allocation
RANDOMIZED
Intervention model
CROSSOVER
Primary purpose
TREATMENT
Masking
DOUBLE (Subject, Investigator)

Eligibility

Sex/Gender
ALL
Age
18 Years to 39 Years
Healthy volunteers
Yes

Inclusion criteria

Potential subjects must satisfy all of the following criteria to be enrolled in the study: 1. Read, understand, and sign the STATEMENT OF INFORMED CONSENT and receive a fully executed copy of the form. 2. Appear able and willing to adhere to the instructions set forth in this clinical protocol. 3. Be between 18 and 39 (inclusive) years of age at the time of screening. 4. By self-report, habitually wear soft contact lenses in both eyes in a daily reusable or daily disposable wear modality (i.e. not extended wear modality). Habitual wear is defined as a minimum of 6 hours of wear per day, for a minimum of 2 days per week during last 30 days. 5. Possess a wearable pair of spectacles that provide correction for distance vision. 6. In both eyes, have astigmatic refractive error suitable for correction with the toric contact lens powers available in this study: 1. Sphere powers (DS) -1.50 through -4.00 (inclusive) in 0.25 steps 2. Cylinder powers (DC) -0.75 and -1.25 3. Axes (°) 170, 180, 10, 80, 90, 100 7. Have best corrected monocular distance visual acuity of 20/30 or better in each eye. Potential subjects who meet any of the following criteria will be excluded from participating in the study: 1. Be currently pregnant or lactating. 2. Be diabetic. 3. Be currently using any ocular medications or have an ocular infection of any type. 4. By self-report, have any ocular or systemic disease, allergies, infection, or use of medication that might contraindicate or interfere with contact lens wear, or otherwise compromise study endpoints, including infectious disease (e.g., hepatitis, tuberculosis), contagious immunosuppressive disease (e.g., Human Immunodeficiency Virus \[HIV\]), autoimmune disease (e.g. rheumatoid arthritis, Sjögren's syndrome), or history of serious mental illness or seizures. See section 9.1 for additional details regarding excluded systemic medications. 5. Have habitually worn rigid gas permeable (RGP) lenses, orthokeratology lenses, or hybrid lenses (e.g. SynergEyes, SoftPerm) within the past 6 months. 6. Be currently wearing monovision or multifocal contact lenses. 7. Be currently wearing lenses in an extended wear modality. 8. Have a history of strabismus or amblyopia. 9. Be an employee (e.g., Investigator, Coordinator, Technician) or immediate family member of an employee (including partner, child, parent, grandparent, grandchild or sibling of the employee or their spouse) of the clinical site. 10. Have participated in a contact lens or lens care product clinical trial within 7 days prior to study enrollment. 11. Have clinically significant (grade 3 or higher on the FDA grading scale) slit lamp findings (e.g., corneal edema, neovascularization or staining, tarsal abnormalities or bulbar injection) or other corneal or ocular disease or abnormalities that contraindicate contact lens wear or may otherwise compromise study endpoints (including entropion, ectropion, chalazia, recurrent styes, glaucoma, history of recurrent corneal erosions, aphakia, moderate or above corneal distortion, herpetic keratitis). 12. Have fluctuations in vision due to clinically significant dry eye or other ocular conditions. 13. Have had or have planned (within the study period) any ocular or intraocular surgery (e.g., radial keratotomy, Photorefractive Keratectomy \[PRK\], Laser-Assisted in Situ Keratomileusis \[LASIK\], iridotomy, retinal laser photocoagulation, etc.).

Design outcomes

Primary

MeasureTime frameDescription
Distance Monocular logMAR Visual Acuity1-Week Follow-upDistance Monocular visual acuity was measured on a logMAR (Logarithm of Minimal Angle of Resolution) scale under high luminance high contrast condition. Visual acuity is assessed using ETDRS (Early Treatment Diabetic Retinopathy Study) charts. Letter-by-letter results calculated the visual performance score for each chart read. LogMAR scores closer to zero, or below zero, indicate better visual acuity. A logMAR visual performance score of 0.0 is equivalent to Snellen visual acuity of 20/20.
Proportion of Eyes With Absolute Rotation Less Than or Equal to 10 Degrees15-Minutes after Lens InsertionAbsolute rotation was assessed for each subject eye using a slit lamp 15 minutes after lens insertion. Acceptable absolute rotation was dichotomized into a binary response where Y=1 if absolute rotation was less than or equal to 10 degrees and Y=0 otherwise (absolute rotation greater than 10 degrees). The proportion of eyes with absolute rotation less than or equal to 10 degrees was reported for each lens.
Proportion of Eyes With Rotational Stability Less Than or Equal to 5 Degrees15-minutes after lens insertionRotational Stability was assessed for each subject eye using a slit lamp 15 minutes after lens insertion. Rotational Stability was dichotomized into a binary response where Y=1 if Rotational Stability was less than or equal to 5 degrees and Y=0 otherwise (Rotational Stability greater than 5 degrees). The proportion of eyes with Rotational Stability less than or equal to 5 degrees was reported for each lens.
Proportion of Eyes With Grade 3 or Higher Slit Lamp FindingsUp to 1-Week Follow-upSlit Lamp Findings (SLF) were assessed using a biomicroscope and were graded using the FDA grading scale (Grade: 0, 1,2, 3 and 4) with grade 0 represents the absence of findings and 1 to 4 representing successively worse findings (i.e. Grade 1 = trace, Grade 2 = Mild, Grade 3 = moderate and Grade 4 = severe). This was performed on each subject eye at every study visit (baseline, unscheduled visits and 1-week follow-up). The data was then dichotomized into two groups. Those with grade 3 or higher and those with grade 2 or lower. The proportion of eyes with SLF with grade 3 or higher was reported for each lens.
Proportion of Eyes With Acceptable Lens FittingUp to 1-Week Follow-upContact lens fitting acceptance was assessed for each subject eye using a biomicroscope post lens insertion at the 1-week follow-up. Lens fit was a binary variable where acceptable lens fit=1 and unacceptable lens fit=0. The proportion of eyes with acceptable lens fit was reported for each lens.

Secondary

MeasureTime frameDescription
CLUE Vision Score1-Week Follow-upSubjective vision was assessed using the Contact Lens User Experience™ (CLUE) questionnaire. CLUE is a validated patient-reported outcomes (PRO) questionnaire to assess patient-experience attributes of soft contact lenses (comfort, vision, handling, and packaging) in a contact-lens wearing population in the US, ages 18-65. Derived CLUE scores using Item Response Theory (IRT) follow a normal distribution with a population average score of 60 (SD 20), where higher scores indicate a more favorable/positive response with a range of 0-120.
CLUE Comfort Score1-Week Follow-upSubjective comfort was assessed using the Contact Lens User Experience™ (CLUE) questionnaire. CLUE is a validated patient-reported outcomes (PRO) questionnaire to assess patient-experience attributes of soft contact lenses (comfort, vision, handling, and packaging) in a contact-lens wearing population in the US, ages 18-65. Derived CLUE scores using Item Response Theory (IRT) follow a normal distribution with a population average score of 60 (SD 20), where higher scores indicate a more favorable/positive response with a range of 0-120.
CLUE Handling Score1-Week Follow-upSubjective handling was assessed using the Contact Lens User Experience™ (CLUE) questionnaire. CLUE is a validated patient-reported outcomes (PRO) questionnaire to assess patient-experience attributes of soft contact lenses (comfort, vision, handling, and packaging) in a contact-lens wearing population in the US, ages 18-65. Derived CLUE scores using Item Response Theory (IRT) follow a normal distribution with a population average score of 60 (SD 20), where higher scores indicate a more favorable/positive response with a range of 0-120.

Countries

United States

Contacts

STUDY_DIRECTORJohnson & Johnson Vision Care, Inc. Clinical Trial

Johnson & Johnson Vision Care, Inc.

Participant flow

Pre-assignment details

A total of 281 subjects were enrolled in this study. Of those enrolled, 274 subjects were dispensed at least one study lens, while 7 subjects failed to meet all eligibility criteria. Of those dispensed, 272 subjects completed the study while 2 subjects were discontinued.

Baseline characteristics

Characteristic
Age, Continuous29.6 Years
STANDARD_DEVIATION 6.16
Race (NIH/OMB)
American Indian or Alaska Native
3 Participants
Race (NIH/OMB)
Asian
15 Participants
Race (NIH/OMB)
Black or African American
17 Participants
Race (NIH/OMB)
More than one race
5 Participants
Race (NIH/OMB)
Native Hawaiian or Other Pacific Islander
3 Participants
Race (NIH/OMB)
Unknown or Not Reported
0 Participants
Race (NIH/OMB)
White
231 Participants
Region of Enrollment
United States
274 Participants
Sex: Female, Male
Female
171 Participants
Sex: Female, Male
Male
103 Participants

Adverse events

Event typeEG000
affected / at risk
EG001
affected / at risk
deaths
Total, all-cause mortality
0 / 2730 / 272
other
Total, other adverse events
0 / 2730 / 272
serious
Total, serious adverse events
0 / 2730 / 272

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Sep 16, 2026