Skip to content

Assess the Potential of the IVC Distensibility Index as a Predictor of Postoperative Fluid Status in Children.

Correlation Between Intraoperative Fluid Volume and Postoperative Inferior Vena Cava Distensibility Index in Pediatric Operations

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT06957171
Enrollment
15
Registered
2025-05-04
Start date
2024-04-01
Completion date
2024-08-31
Last updated
2025-05-04

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Inferior Vena Cava Diameter, Intraoperative Fluid Volume

Brief summary

The investigators will assess the relationship between the amount of fluid administered during pediatric surgery and the subsequent IVC distensibility index postoperatively.

Detailed description

Preoperative settings: Preoperative assessment will be done which includes Medical History and Clinical Examination: Age, gender, and weight will be recorded, Number of fasting hours, Surgical History documentation of previous surgeries, if any, including details on anesthetic techniques. family history of cardiovascular, renal, or fluid balance disorders. Information on any known allergies, particularly to medications, as well as a list of current medications being taken by the patient. Any coexisting medical conditions, particularly autoimmune, inflammatory, or chronic diseases, will be documented (e.g., asthma, diabetes, renal insufficiency). Specific Examination for IVC Distensibility: • Ultrasonographic Examination: Preoperative ultrasound will be used to measure the baseline Inferior Vena Cava (IVC) diameter and assess its distensibility as a part of the preoperative evaluation. Preoperative Assessment of Fluid Balance: • Laboratory Tests: Baseline blood tests, including complete blood count, serum electrolytes, and renal function tests, will be performed to assess overall fluid and electrolyte balance. Intraoperative Monitoring: Intraoperative fluid strategy will be followed with the local protocol 10 ml/kg/h will be given, and additional boluses 10-20 ml/kg if needed (in case of hemodynamic instability, increasing lactate), losses will be compensated with fluid or blood (if exceeded the allowable blood loss). This fluid regimen is individualized by the attending anaesthesiologist according to the actual requirement, The volume of fluids administered intraoperatively will be meticulously recorded. Urine Output Documentation of baseline urine output as an indicator of renal function and fluid status. Postoperative Settings: All ultrasonographic measurments of IVC will be performed at the end of surgery, before extubation (patient is anaesthetized and completely relaxed, in the supine position, PEEP less than 7 cmH2O and tidal volume 6-8 ml/kg The probe will be placed at the sub xiphoid area and measurements will be obtained in M-mode imaging performed 2 to 3 cm distal to the right atrium in the long-axis subcostal view..IVC diameter during inspiration (IVCi) and expiration (IVCe) will be measured, Collapsibility index (CI) measured as difference between IVCe, IVCi divided on IVCe (CI = IVCe - IVCi /IVCe x100).

Interventions

None listed

Sponsors

Ain Shams University
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
1 Years to 12 Years
Healthy volunteers
Yes

Inclusion criteria

* Pediatric patients aged 1-12 years. * ASA status I - II * Patients undergoing elective surgical procedures requiring general anesthesia.

Exclusion criteria

* Patients with known congenital heart disease, valvular heart disease or Pulmonary hypertension * Renal disorders (Acute or Chronic). * PEEP more than 7 cmH2O at time of assessment of IVC distensibility index

Design outcomes

Primary

MeasureTime frameDescription
Inferior Vena Cava distensibility indexAt the end of surgery, before extubationAll ultrasonographic measurments of IVC will be performed at the end of surgery, before extubation (patient is anaesthetized and completely relaxed, in the supine position, PEEP less than 7 cmH2O and tidal volume 6-8 ml/kg The probe will be placed at the sub xiphoid area and measurements will be obtained in M-mode imaging performed 2 to 3 cm distal to the right atrium in the long-axis subcostal view..IVC diameter during inspiration (IVCi) and expiration (IVCe) will be measured, Collapsibility index (CI) measured as difference between IVCe, IVCi divided on IVCe (CI = IVCe - IVCi /IVCe x100).

Countries

Egypt

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026