Skip to content

External Validation of Prediction Algorithm Using Non-invasive Monitoring Device for Intraoperative Hypotension

External Validation of Prediction Algorithm Using Non-invasive Monitoring Device for Intraoperative Hypotension

Status
Recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT06897514
Enrollment
200
Registered
2025-03-27
Start date
2025-04-11
Completion date
2025-12-31
Last updated
2025-05-15

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Hypotension During Surgery

Keywords

intraoperative hypotension, prediction algorithm

Brief summary

The goal of this prospective observational study is to externally validate the prediction algorithm using non-invasive monitoring device for intraoperative hypotension. The main question it aims to answer is: Does the prediction algorithm predict intraoperative hypotension effectively?

Detailed description

The hypotension that occurs during surgery is associated with the poor prognosis of patients after surgery. Previous studies have reported that even a short period of time of hypotension increases the risk of postoperative complications such as kidney injury. If anesthesiologists can predict intraoperative hypotension in advance, they can prevent or minimize the damage. Recently, there are many reports on medical artificial intelligence models that predict the intraoperative hypotension. Among them, the Hypotension Prediction Index (HPI) model has already been commercialized and used in clinical practice. However, HPI has limitations in that it is necessary to perform invasive techniques (arterial cannulation) or to use dedicated equipment at high cost. However, since many of the general anesthesia are performed without invasive monitoring devices, the use of HPI medical devices is subject to considerable restrictions. The investigators have reported the prediction algorithm for intraoperative hypotension using five non-invasive monitoring devices commonly used in general anesthesia: 1) blood pressure (NBP, number), 2) electrocardiogram (ECG, waveform), 3) end-oxygen saturation waveform (PPG, waveform), 4) end-stage carbon dioxide waveform (ETCO2, waveform), and 5) an anesthesia depth (BIS, number) By conducting a retrospective external validation process using public clinical data from other institutions (tertiary hospital in Korea), the final model was able to have good predictability with an Area Under the Receiver-Operating Characteristic Curve (AUROC) value of 0.917. However, investigators did not externally validate that algorithm through a prospective designed study. This study intends to externally validate the hypertension prediction model during surgery using non-invasive monitoring device, which has already reported It is expected that the usefulness and limitations of the prediction model can be evaluated again, and the model can be advanced based on the results.

Interventions

DIAGNOSTIC_TESTPrediction algorithm for intraoperative hypotension

All participants will receive five non-invasive monitoring during their surgery. Data from these monitoring device will be put into the prediction algorithm.

Sponsors

Samsung Medical Center, Sungkyunkwan University School of Medicine
CollaboratorUNKNOWN
Samsung Medical Center
Lead SponsorOTHER

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
19 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Adults patients aged 19 or more * Elective surgery under general anesthesia * American Society of Anesthesiologists physical status I - III

Exclusion criteria

* Vasopressor/Inotrope usage before surgery * Patients who needs invasive arterial cannulation * Emergency surgery * Pregnant or lactating women

Design outcomes

Primary

MeasureTime frameDescription
Value of the Area Under the Receiver-Operating Characteristic curve analysis5 minutes before the occurrence of hypotension during general anesthesiaThe area under the receiver operating characteristic curve is a measurement of how well a prediction model can predict intraoperative hypotension. It is used to assess the performance of algorithm.

Countries

South Korea

Contacts

Primary ContactHyun Joo Ahn, MD PhD
hyunjooahn@skku.edu821099330784

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026