Aortic Aneurysm Abdominal
Conditions
Brief summary
This study is a clinical investigation as part of the post-market clinical follow-up of the TREO® abdominal aortic graft in its initial use, French, observational, multicenter, non-randomized, single-arm. Information on patient's health and the implanted device will be collected over a period of 5 consecutive years. The data collected will be analyzed on the technical success and the absence of major events (death, stroke, myocardial infarction, visceral ischemia, paraplegia, respiratory failure, renal failure, intraoperative blood loss, thromboembolic event) and possible reinterventions related to the patient's operation.
Interventions
Post Market collection data in use of TREO modular endografts
Sponsors
Study design
Eligibility
Inclusion criteria
1. Patient who has confirmed his/her non-opposition to the use of his/her data in the study. 2. Patient aged 45 years or older. 3. Patient with AAA with one of the following criteria: * Maximum diameter ≥50 mm for women and ≥55 mm for men * Rapid growth (≥5 mm in 6 months or ≥10 mm in 12 months) * Unruptured AAA with clinical symptoms of abdominal pain 4. Adequate anatomy for TREO® stent graft implantation, including: * Adequate iliac and femoral arteries for the modular system * Suprarenal angle less than 45 degrees * Infrarenal aortic neck greater than or equal to 10 mm in length with an angle less than 60° and an internal diameter of 17mm-32mm, or an infrarenal aortic neck greater than or equal to 15 mm in length with an angle between 60 and 75° and an internal diameter of 16mm-30mm * Distal iliac sealing distance ≥ 10 mm and an iliac diameter between 8-13 mm or a distal iliac sealing distance ≥ 15 mm and a diameter between 13-21 mm 5. Ability to follow the entire protocol from 1 to 60 months 6. Life expectancy greater than 2 years
Exclusion criteria
1. Patients refusing treatment and follow-up as part of the study 2. Infected or ruptured aneurysm 3. Associated aortic lesion (thoracic or thoracoabdominal aneurysm) requiring management 4. Renal failure defined by creatinine \> 2.5 mg/dL or patient in pre-dialysis status and impossibility of intervention with use of CO2 injection 5. New York Heart Association (NYHA) class IV 6. Aneurysmal, dissected distal implantation zone, or including calcifications and/or significant thrombus that could compromise sealing 7. Tortuous iliac and/or femoral access and/or including calcified stenosis 8. Systemic infection that could increase the risk of infection of the endoprosthesis 9. Pathology of the supporting tissues such as collagenosis (Marfan or Ehler-Danlos, etc.) 10. Known drug use 11. Known sensitivity or allergy to the materials to be implanted 12. Patients contraindicated for antiplatelet treatment 13. Patients with an uncontrolled hematological disorder or heparin-induced thrombocytopenia 14. Patients who are pregnant or planning to become pregnant 15. Patients considered hemodynamically unstable or requiring emergency treatment 16. Patients with severe arterial disease leading to a negative outflow that may degrade the permeability of implanted stents 17. Scheduled hybrid aortic technique (surgical and endovascular) 18. Patients with complex iliac access outside the manufacturer's indications and recommendations that may lead to procedural failure
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| The primary outcomes of this study are the rate of a composite measure of technical and clinical success at 1 and 12 months to assess efficacy, and the rate of a composite measure of free from major adverse events at 1 month to assess safety. | 12 months | Definition of the composite of technical success: * Successful access to the arterial system using remote arterial exposure, percutaneous technique, surgical access, or open surgical conduits. * Successful delivery and deployment of all components of the modular stent graft. * Absence of type I or type III endoleaks at the end of angiography that extend beyond 30 days confirmed by imaging\*. * Patency of all components of the modular stent graft. Definition of the composite of clinical success : * Technical success * No death during the initial procedure, related to the procedure or from aortic-related causes during the initial hospitalization * No type I and III endoleaks, at 1 and 12 months * No early migration (\> 10 mm), at 1 and 12 months * No increase in maximum sac diameter of more than 5 mm between 1 and 12 months * No aneurysm rupture, at 1 and 12 months * No surgical conversion related to aneurysm treatment, at 1 and 12 months |