Skip to content

Use of Ultrasonography for Measuring Achilles Tendon Thickness: a Novel Measurement Method

Use of Ultrasonography for Measuring Achilles Tendon Thickness: a Novel Measurement Method

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT06867211
Enrollment
180
Registered
2025-03-10
Start date
2024-09-19
Completion date
2024-10-20
Last updated
2025-03-10

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Achilles Tendon, Emergency Medicine, Ultrasonography

Keywords

achilles tendon, emergency medicine, ultrasonography

Brief summary

Background: Achilles tendon thickness has been associated with various diseases. Among imaging modalities, ultrasonography stands out because of its advantages in assessing Achilles tendon thickness. Previous studies typically recommend performing Achilles tendon ultrasonography with the patient in a prone position on an examination table. However, because it is not always possible or safe for each patient to assume the prone position, this study aimed to investigate the relationship between measurements obtained in the supine position and those obtained using the standard method. Methods: A total of 180 healthy volunteers aged ≥18 years (70 female and 110 male; 360 Achilles tendons), with no history of disease or medication use, were included in the study. Achilles tendon measurements (thickness, width, and cross-sectional area) were obtained via ultrasonography in four different positions, including the standard method. The alternative methods included the supine position with the leg extended (Method 2), the supine position with the ankle resting on the opposite knee (Method 3), and the supine position with the leg held in the air at 90 degrees of hip and knee flexion (Method 4). Measurements were taken 2 cm distal from the Achilles tendon insertion on the calcaneus.

Interventions

DIAGNOSTIC_TESTUse of Ultrasonography for Measuring Achilles Tendon Thickness

Achilles tendon ultrasonography was performed on healthy volunteers included in the study by an emergency physician trained in both basic and advanced ultrasonography techniques. Measurements were conducted using a Butterfly iQ (Butterfly Network, Inc., Guilford, CT) ultrasound device in B-mode with a musculoskeletal preset, using biplane imaging. For Achilles tendon measurement, the image depth was set to 2.0 cm. A linear probe was placed longitudinally and perpendicular to the tendon. The distal portion of the Achilles tendon and the calcaneus were visualized in the long axis, whereas the short axis was used to center the Achilles tendon on the screen for an optimal measurement view. The measurement site was determined as 2 cm proximal to the Achilles tendon insertion at the calcaneus. In biplane imaging, Achilles tendon thickness was measured in the long axis, whereas thickness, width, and cross-sectional area were measured in the short axis. Measurements were performed bilaterally

Sponsors

Sakarya University
Lead SponsorOTHER

Study design

Observational model
CASE_ONLY
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
Yes

Inclusion criteria

* Healthy volunteers aged \>18 years who agreed to participate in the study

Exclusion criteria

* Individuals with tenosynovitis, tendinitis, bursitis, tuberculous arthritis, rheumatoid arthritis, a history of Achilles tendon surgery, or tendon injuries.

Design outcomes

Primary

MeasureTime frameDescription
A novel ultrasonographic technique for achilles tendon thickness measurementBaselineThe primary outcome of this study was to provide a practical method for Achilles tendon measurement in emergency departments by addressing the disadvantages of the prone measurement technique proposed in previous studies.

Countries

Turkey (Türkiye)

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026