The Effect of Clip Material on the Retention of Implant Supported Mandibular Overdenture

The Effect of Clip Material on the Retention of Implant Supported Mandibular Overdenture: Clinical Comparative Study

Status
Completed
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06866067
Enrollment
12
Registered
2025-03-10
Start date
2024-02-01
Completion date
2024-09-01
Last updated
2025-03-10

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Denture Retention

Brief summary

This study is aiming to evaluate the retention of implant supported mandibular overdenture using two different clip materials namely polyoxymethylene (POM) and poly-ether-ether-ketone (PEEK) on PEEK bar at three-time intervals; immediately after placement, after 3 months and after 6 months.

Interventions

DEVICEPEEK clip

The overdentures were attached with PEEK clip . The retention of overdenture was assessed

DEVICENylon clip

The overdentures were attached with Nylon clip . The retention of overdenture was assessed

Sponsors

MTI University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
MALE
Age
50 Years to 60 Years
Healthy volunteers
No

Inclusion criteria

* Inclusion criteria: * Male. * Completely edentulous. * Age: 50-60 years. * Free from any systemic diseases that affect bone metabolism. * Good intraoral condition. * Anterior mandibular bone height \> 13mm and width \> 5mm. * The inter-arch space from 15mm to 17mm.

Exclusion criteria

* Smoking and drug abusing. * Severe maxillomandibular skeletal discrepancy. * Bone metabolic disorders. * History of head and neck radiotherapy. * Intravenous bisphosphonate therapy. * Presence of para-functional habits. * Temporomandibular joint disorders. * Severe bony undercuts.

Design outcomes

Primary

MeasureTime frameDescription
Overdenture retention assessed using Universal Testing Machine (Newton)From enrollment and after 3 months and finally at the end of treatment at 6 monthsDenture resistance corresponding to vertical displacement force was obtained using a universal testing machine (INSTRON, United States) to measure retention. Each patient had his chin securely fixed on a support while seated upright. The attachment portion of the universal machine was adjusted in accordance with the device's bar being securely attached to the denture. The device gradually increased the vertical load by 10 mm per minute until the denture completely fell out of place. A tuck sound can be heard to indicate the load at the dislodgment point. Additionally, the force plot in the recorded computer software data exhibits an abrupt drop (Nexyge; Lloyd Instruments; MT-4.6). Each test was repeated five times to obtain five records, and the mean of these records was calculated. Testing was carried out on the mandibular overdenture after insertion, as well as at 3 and 6 months.

Countries

Egypt

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026