Skip to content

A Comparative Analysis of Preoperative Liver Volumetry in Living Donor Liver Transplantation

Optimizing Accuracy: a Comparative Analysis of Preoperative Liver Volumetry in Living Donor Liver Transplantation from a Surgeon's Perspective

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT06865612
Enrollment
109
Registered
2025-03-10
Start date
2011-11-01
Completion date
2025-01-31
Last updated
2025-03-10

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Liver Failure, Living Donor Liver Transplantation

Brief summary

Accurate preoperative graft volume assessment is crucial for successful living donor liver transplantation (LDLT). Although manual and automated computed tomography (CT) volume measurement methods using various volumetric tools are widely used, their accuracy remains uncertain. This study aimed to determine the optimal dry weight correction factor for each method to enhance the prediction of actual graft weight (AGW) and compare the accuracy of different methods.

Detailed description

This study is a retrospective diagnostic accuracy study comparing three liver volumetry methods using preoperative donor CT scans in LDLT.

Interventions

None listed

Sponsors

Chungnam National University Hospital
Lead SponsorOTHER

Study design

Observational model
OTHER
Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

* Patients who underwent hepatectomy for living donor liver transplantation performed by the Department of Surgery at Chungnam National University Hospital under the supervision of the principal investigator.

Exclusion criteria

* Patients deemed unsuitable for participation in this clinical study by the investigator.

Design outcomes

Primary

MeasureTime frameDescription
Accuracy of preoperative estimated graft volume (EGV) compared to actual graft weight (AGW)From preoperative CT scan (1-2 months before transplantation) to intraoperative measurement (day of transplantation)The accuracy of preoperative donor CT liver volumetry will be assessed by comparing estimated graft volume (EGV) obtained from three methods (automated, semi-automated, manual) with the actual graft weight (AGW) measured intraoperatively. The error ratio between EGV and AGW will be calculated for each method.

Secondary

MeasureTime frameDescription
Determination of the optimal dry weight correction factor for each volumetry methodFrom preoperative CT scan (1-2 months before transplantation) to intraoperative measurement (day of transplantation)The study aims to determine the optimal dry weight correction factor by minimizing the discrepancy between EGV and AGW.

Countries

South Korea

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026