Efficacy and Safety of HANAROSTEN® HOT Plumber™ With Z-EUSIT™ for Pancreatic Pseudocyst Drainage

A Prospective Single-Center Observational Study on the Evaluation of Efficacy and Safety of HANAROSTEN® HOT Plumber™ With Z-EUSIT™ for Pancreatic Pseudocysts Drainage

Status
Recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06855485
Acronym
ZEUS
Enrollment
20
Registered
2025-03-03
Start date
2025-02-25
Completion date
2025-12-30
Last updated
2025-03-03

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Pancreatic Pseudocyst

Keywords

Pancreatic Pseudocyst, Endosonography, Drainage, Stents

Brief summary

The goal of this prospective, single-center observational study is to evaluate the safety and effectiveness of the HANAROSTEN® HOT Plumber™ with Z-EUSIT™ for draining pancreatic pseudocysts. The main questions the study aims to answer are: * Does the device reduce the size of pancreatic pseudocysts by at least 50% and improve associated symptoms within 30 to 60 days? * Can the stent be successfully placed, retained, and removed without complications? Participants will: * Undergo endoscopic ultrasound-guided transgastric or transduodenal drainage of pancreatic pseudocysts using the HANAROSTEN® HOT Plumber™ with Z-EUSIT™. * Be monitored for adverse events such as bleeding, infection, stent migration, or tissue injury. * Return for follow-up visits within 30 or 60 days for stent removal and evaluation of clinical success. The study will: * Enroll 20 adults aged 18 years or older who meet the inclusion criteria. * Conduct follow-up assessments until one month after stent removal.

Detailed description

Detailed Description This prospective, single-center observational study aims to evaluate the safety and effectiveness of the HANAROSTEN HOT Plumber with Z-EUSIT for pancreatic pseudocyst drainage. The study will assess clinical success, defined as a reduction of at least 50% in pseudocyst size accompanied by symptom improvement, as well as technical success, device retention, lumen patency, and adverse events. Follow-up will continue until one month after stent removal. \### Study Rationale * Pancreatic pseudocysts develop due to pancreatic duct obstruction or damage caused by inflammation, resulting in fluid accumulation. Symptoms may include abdominal pain, gastric outlet obstruction, early satiety, and weight loss. Drainage is required when pseudocysts become symptomatic, infected, or increase in size. * Endoscopic ultrasound-guided transgastric or transduodenal drainage is the standard treatment for accessible pseudocysts. Compared to surgical or percutaneous methods, this approach is less invasive and promotes faster recovery. * The HANAROSTEN HOT Plumber with Z-EUSIT features an electrocautery-enhanced delivery system, eliminating the need for guidewire exchanges and tract dilation. The stent is made of nitinol wire with silicone coating and anti-migration bi-flanges, designed for easy placement and removal. Study Design * Type: Prospective, single-center, observational study * Device: HANAROSTEN HOT Plumber with Z-EUSIT * Target Enrollment: 20 adults aged 18 years or older * Procedure: Endoscopic ultrasound-guided transgastric or transduodenal drainage of pancreatic pseudocysts * Follow-Up: Until one month after stent removal Procedure Overview * Prior to the procedure, cross-sectional imaging (CT or MRI) will determine pseudocyst size and proximity to the gastrointestinal lumen, guiding stent selection. * Patients will receive prophylactic antibiotics and sedation with midazolam and pethidine according to institutional protocols. * Under EUS guidance, the pseudocyst will be punctured using the electrocautery-enhanced delivery system. The stent will be deployed to create a connection between the pseudocyst and the gastrointestinal lumen, allowing fluid drainage. * If direct puncture is not feasible, a 19-gauge needle will be used to access the pseudocyst, followed by guidewire placement and stent deployment. * Stent removal will occur after pseudocyst resolution, confirmed by follow-up imaging, and will be performed using forceps or a snare. Follow-Up and Safety Monitoring * Participants will be monitored for adverse events, including bleeding, infection, perforation, stent migration, tissue injury, and other complications. * Follow-up visits will occur within 30 or 60 days after the procedure, and one month after stent removal. * Safety monitoring will include clinical assessments, laboratory tests, and imaging studies as required. Data Collection and Statistical Analysis * Data will be summarized using descriptive statistics. Continuous variables will be reported as mean ± standard deviation or median (interquartile range), and categorical variables as frequencies and percentages. * Technical success rates will be calculated as the percentage of successful stent placements and removals. Clinical success rates will be reported as the percentage of participants with ≥50% pseudocyst size reduction and symptom improvement. * Adverse events will be classified according to severity and relationship to the device. The incidence of stent migration, retention, and lumen patency will also be reported. * Missing data will be handled using the last observation carried forward (LOCF) method. Ethical Considerations * The study will be conducted in accordance with the Declaration of Helsinki and Good Clinical Practice guidelines. * All participants will provide written informed consent before enrollment. * Personal data will be anonymized and securely stored, accessible only to authorized study personnel. This study aims to provide clinical evidence supporting the safety and effectiveness of the HANAROSTEN HOT Plumber with Z-EUSIT for pancreatic pseudocyst drainage, potentially improving outcomes for patients with this condition.

Interventions

DEVICEHANAROSTEN® HOT Plumber™ with Z-EUSIT™

An electrocautery-enhanced lumen-apposing metal stent designed for the drainage of pancreatic pseudocysts. The stent is delivered using a system that allows for single-step deployment without the need for guidewire exchanges or tract dilation.

Sponsors

M.I.Tech Co., Ltd.
CollaboratorUNKNOWN
Asan Medical Center
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Intervention model description

The design is non-randomized, with no control or comparison group. The study aims to assess both clinical and technical success, as well as device-related safety outcomes.

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Must be 18 years or older * Diagnosed with pancreatic or peripancreatic pseudocyst or walled-off necrosis (with less than 30% solid components) * Eligible for endoscopic ultrasound-guided drainage * Able to provide informed consent and comply with study procedures

Exclusion criteria

* Younger than 18 years old * Pseudocysts with the following characteristics: * Immature pseudocyst * Cystic neoplasm * Pseudoaneurysm * Multiple pseudocysts requiring drainage * Uncontrolled coagulation disorders: * INR \> 1.5 * Platelet count \< 50,000/mm³ * Other bleeding disorders * Ineligibility for EUS-guided drainage due to anatomical or technical reasons * History of anaphylactic reaction to stent materials * Pregnant or potentially pregnant women * Current participation in another clinical trial that may affect study outcomes

Design outcomes

Primary

MeasureTime frameDescription
Clinical SuccessWithin 30 or 60 days after stent placementReduction of pancreatic pseudocyst size by at least 50% with improvement in associated symptoms.

Secondary

MeasureTime frameDescription
Technical Success - Stent RemovalWithin 30 or 60 days after placementSuccessful removal of the stent after pseudocyst resolution, confirmed by endoscopic confirmation of complete stent removal without residual fragments.
Stent RetentionWithin 30 or 60 days after placementRetention of the stent in the intended location without migration until removal.
Technical Success - Stent PlacementDuring procedureSuccessful deployment of the stent at the intended site.
Procedure DurationDuring procedureTime from initial needle puncture to full deployment of the stent.
Adverse EventsFrom procedure day until one month after stent removalIncidence of complications such as bleeding, infection, perforation, stent migration, tissue injury, or other adverse events.
Lumen PatencyWithin 30 or 60 days after placementMaintenance of an open lumen allowing fluid drainage until stent removal.

Countries

South Korea

Contacts

Primary ContactTae Jun Song, MD, PhD
medi01@naver.com82-2-3010-3914
Backup ContactYoonchan Lee, MD
ycrlee@gmail.com82-2-3010-1397