Establish the First International Database on Semi-quantitative Values Obtained in Scintigraphy With Datscan® in Cadmium-Zinc-Telluride Camera

Establish the First International Database on Semi-quantitative Values Obtained in Scintigraphy With Datscan® in Cadmium-Zinc-Telluride (CZT) Camera (VERITON-CT)

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT06828705
Acronym
DaTBase
Enrollment
300
Registered
2025-02-14
Start date
2025-07-30
Completion date
2025-11-30
Last updated
2026-06-25

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Neurodegenerative Diseases

Brief summary

Datscan scintigraphy is a nuclear medicine examination allowing the diagnosis of neurodegenerative pathologies linked to damage to dopaminergic pathways, such as Parkinson's disease (essential for the differential diagnosis of essential tremor).

Detailed description

Datscan scintigraphy is a nuclear medicine examination allowing the diagnosis of neurodegenerative pathologies linked to damage to dopaminergic pathways, such as Parkinson's disease (essential for the differential diagnosis of essential tremor). There are several types of cameras allowing its performance: * Conventional Anger cameras and, * CZT (Cadmium-Zinc-Telluride) semiconductor cameras. At the Nancy University Hospital, the nuclear medicine department has a wide-field Cadmium-Zinc-Telluride camera: VERITON-CT (Spectrum Dynamics). The interpretation of this examination is purely visual. The objectives are therefore to: * Create the first international database of semi-quantitative values in 3D scintigraphy with Datscan performed with a VERITON-CT camera. * Compare this database with another database from a conventional Anger camera (Lyon Nuclear Medicine Department) to show its superiority.

Interventions

OTHERdatscan scintigraphy

Semi-quantitative analysis on Datscan imaging scintigraphy

Sponsors

Central Hospital, Nancy, France
Lead SponsorOTHER

Study design

Observational model
OTHER
Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 99 Years
Healthy volunteers
No

Inclusion criteria

* Adult patients who have undergone a Datscan scintigraphy on the VERITON camera in the nuclear medicine department of the Nancy University Hospital and who have an established clinical diagnosis, -Absence of neurodegenerative pathology or Parkinson's disease or Lewy body disease. * The clinical diagnosis can only be established after two years of clinical follow-up.

Exclusion criteria

* Excluded from this research will be the patients opposed to the use of their data, minors, atypical Parkinsonian syndromes, * patients who died before two years of clinical follow-up, * patients who had their Datscan examination carried out on a camera other than the VERITON and - patients lost to follow-up.

Design outcomes

Primary

MeasureTime frameDescription
To create the first international database of Datscan by camera VERITON-CT.One dayFixation ratio of central gray nuclei of the brain namely, the global striatum, caudate nuclei, putamens

Secondary

MeasureTime frameDescription
Compare this database with another database from another type of camera (Lyon nuclear medicine team) to show its superiority.One dayIdentical to the primary evaluation criterion compared to those of the Lyon database.

Countries

France

Outcome results

None listed