Skip to content

Effect of Er,Cr:YSGG Sub-Ablative Laser Irradiation on Fissure Caries Prevention in Permanent Molars

Effect of Er,Cr:YSGG Sub-Ablative Laser Irradiation on Fissure Caries Prevention in Permanent Molars

Status
Recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06826456
Enrollment
60
Registered
2025-02-14
Start date
2024-01-01
Completion date
2025-08-31
Last updated
2025-02-14

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Caries,Dental

Keywords

Er,Cr:YSGG, laser, DIAGNOdentTM, acid resistance

Brief summary

Background: Subjecting human dental enamel to sub-ablative laser has been suggested as a novel way of caries prevention. However, further studies are needed to establish its use as a routine clinical procedure for caries prevention. The aim of this study: This study aims to evaluate the effect of Er,Cr:YSGG subablative laser irradiation on caries resistance of occlusal fissures of permanent molars. Materials and methods: In-vivo study, a split mouth randomized controlled trial with sixty patients having two fully erupted bilateral first permanent molars (ICDAS-II score 0,1 or 2). The pits and fissures will be subjected to sub-ablative power of Er,Cr:YSGG Laser (Group 1, n=90) and will be compared with fluoride varnish application on the first permanent molars in the same arch(Group 2,n=90). DIAGNOdentTM readings and changes in ICDAS-II score will be assessed at base line and at 3,6,9 and 12 months follow-up.

Interventions

PROCEDUREsub-ablative Er,Cr:YSGG laser

The irradiations will be done with an Er,Cr:YSGG laser device Er,Cr:YSGG Laser (Waterlase iPlus 2011,Biolase,Germany). This equipment emits photons at a wavelength of 2.78 µm. The repetition rate will be fixed at 20 Hz. The pulse duration will be fixed on 140 µs. The beam diameter at the focal area for the handpiece will be 600 µm. The tip will be positioned 1.0 mm from the enamel surface (focused mode). The handpiece will be positioned perpendicularly to the enamel. Power =0.25 Watt; energy density per pulse will be 62.5 J/cm2, Time = 20 seconds; Frequency = 20 Hz; without air/water. To ensure that each spot of a fissure was irradiated, each fissure will be irradiated for 2 min with overlapping irradiation

The first permanent molar assigned for control group will receive fluoride varnish applications. Fluoride varnish will be applied to all teeth in the oral cavity, including the laser-treated as well as the control tooth at baseline and the 6-month recall. Parents and children will be given age-appropriate oral hygiene instructions including proper teeth brushing with a 1100-ppm fluoride-containing dentifrice for at least 2 min twice daily especially before bedtime, as well as flossing if indicated.

Sponsors

Alexandria University
Lead SponsorOTHER

Study design

Allocation
RANDOMIZED
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
SINGLE (Subject)

Eligibility

Sex/Gender
ALL
Age
6 Years to 12 Years
Healthy volunteers
Yes

Inclusion criteria

* Participants of age 6-12 years old * Patients ranking definitely positive or positive on Frankl behavior rating scale * Having at least two bilateral fully erupted first permanent molars with untreated non-cavitated occlusal surfaces with deep grooves, the included teeth will have International Detection and Assessment System (ICDAS-II)/ severity scores 0, 1 or 2 * Initial DIAGNOdent Score not exceeding value of 25 indicating only enamel involvement * Patients whom their parents are willing to comply with all study procedures and protocols and will be given an informed consent to participate

Exclusion criteria

* Patients with any known medical history of systemic diseases * Patients having first permanent molar with hypoplastic or hypocalcified enamel * Patients using medications that may affect the oral flora or salivary flow * Patients treated with in-office fluoride treatment within the last 3 months prior to being enrolled in the study. * Patients showing evidence of poor oral hygiene according to Silness and Löe plaque index

Design outcomes

Primary

MeasureTime frameDescription
Diagnodent scoringday 0, 3 months, 6 months, 12 monthsevaluate the dental caries activity of fissures by comparing changes in DIAGNOdent readings. Laser induced fluorescence (DIAGNOdentTM) will be used to quantitatively determine lesion demineralization which is displayed as numerical values ranging from 0 to 99. A decrease in the signal indicates regression of the carious lesion, whereas an increase indicates progression. The DIAGNOdent tip will be then placed on the measurement site, and slightly tilted circular movements will be performed along the entire fissure pattern. The patient will be included in the study if the DIAGNOdent readings of both bilateral first permanent molar do not exceed 25.

Countries

Egypt

Contacts

Primary ContactHussein Ezz Eldin
hussein.ezz@hotmail.com+20 10 92403402

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026