A Study to Assess Adverse Events and Effectiveness of Gel Stent (XEN63) Implantation Using Ab Interno and Ab Externo Approaches in Adult Participants With Glaucoma

A Prospective, Multicenter Clinical Study to Evaluate the Safety and Effectiveness of Gel Stent (XEN63) Implantation Using Ab Interno and Ab Externo Approaches in Subjects With Glaucoma

Status
Recruiting
Phases
Phase 3
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06822738
Enrollment
130
Registered
2025-02-12
Start date
2025-02-11
Completion date
2028-11-01
Last updated
2026-09-15

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Primary Open Angle Glaucoma

Keywords

Primary Open Angle Glaucoma, AGN-9003

Brief summary

Glaucoma is the second most common cause of blindness in the world, second only to cataracts. This study will assess how safe and effective a glaucoma gel stent is when implanted using the ab interno (inside the eye) and ab externo (outside the eye) approach. Adverse events and intraocular pressure will be assessed. XEN63 is an investigational device for the treatment of intraocular pressure (IOP) in patients with glaucoma when both medical and conventional surgical treatments have failed (for US approval) and when medical treatments have failed (for outside US \[OUS\] approval). Participants will be placed in one of two groups called study arms. One group will receive the XEN63 gel stent ab interno (inside the eye) and the other group will receive the XEN63 gel stent ab externo (outside the eye). Approximately 130 participants aged 45 years or older with glaucoma will be enrolled in this study at approximately 32 sites in the United States. Participants will receive XEN63 implanted using either the ab interno approach or the ab externo approach on Day 1 and will be followed for 12 months. Participants will attend regular visits during the study at a hospital or clinic. The safety and effect of the gel stent on your glaucoma will be checked by medical assessments and eye examinations.

Interventions

DEVICEXEN63 Glaucoma Treatment System

Gel Stent

Sponsors

AbbVie
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
PARALLEL
Primary purpose
TREATMENT
Masking
SINGLE (Subject)

Eligibility

Sex/Gender
ALL
Age
45 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Diagnosis of glaucoma in the study eye (SE) (meeting criterion a or b) 1. That meets the following refractory glaucoma criteria of eyes diagnosed with glaucoma uncontrolled by maximal medical therapy (four or more classes of intraocular pressure (IOP)-lowering medications, or fewer in cases where it has been documented that certain medication classes cannot be tolerated or are contraindicated), and failed one or more incisional intraocular glaucoma surgeries (e.g., glaucoma filtering surgery, tube shunt) 2. Uncontrolled by medical therapy (to meet out-of-US \[OUS\] requirements) with participants who only have glaucoma uncontrolled by medical therapy (non-refractory glaucoma), a maximum of 10 participants who meet only criterion b (and not a) will be enrolled in each cohort.

Exclusion criteria

* History of angle-closure glaucoma where the angle has not been surgically opened in the SE. * History of secondary open-angle glaucoma (e.g., neovascular, pigmentary, pseudoexfoliative, uveitic, angle recession/traumatic glaucoma, etc.) in the SE. * Active inflammation (e.g., blepharitis, conjunctivitis, keratitis, uveitis) in the SE.

Design outcomes

Primary

MeasureTime frameDescription
Percentage of Participants With Treatment Response of Achieving ≥ 20% Reduction in Intraocular Pressure (IOP) From Baseline on the Same or Fewer Number of IOP-Lowering Medications Compared to BaselineMonth 12IOP is a measurement of the fluid pressure inside the study eye. Treatment response is defined as IOP reduction on the same or fewer number of topical IOP-lowering medications.
Number of Participants with Adverse Events (AEs)Month 12An AE is defined as any untoward medical occurrence in a patient or clinical investigation in which a participant is administered a pharmaceutical product which does not necessarily have a causal relationship with this treatment.

Secondary

MeasureTime frameDescription
Mean Diurnal IOPMonth 12IOP is a measurement of the fluid pressure inside the eye. The mean diurnal IOP was the average of the IOP values of the study eye at Month 12.
Change From Baseline in Diurnal IOPBaseline to Month 12IOP is a measurement of the fluid pressure inside the study eye. A negative change from baseline indicates an improvement and a positive change from baseline indicates a worsening.
Change from Baseline in Number of Topical IOP-Lowering MedicationsBaseline to Month 12A numerical count by class of drug of topical IOP lowering medications being taken.
Mean Number of Topical IOP-Lowering MedicationsMonth 12A numerical count by class of drug of topical IOP lowering medications being taken.

Countries

United States

Contacts

CONTACTABBVIE CALL CENTER
abbvieclinicaltrials@abbvie.com844-663-3742
STUDY_DIRECTORABBVIE INC.

AbbVie

Outcome results

None listed