Skip to content

Evaluation of Flow Diverter Technology Device for Intracranial Aneurysm (SHIELD)

Evaluation of Flow Diverter Technology Device for Intracranial Aneurysm (SHIELD)

Status
Recruiting
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06793059
Acronym
SHIELD
Enrollment
10
Registered
2025-01-27
Start date
2025-01-01
Completion date
2027-01-01
Last updated
2026-03-10

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Aneurysm

Brief summary

The Jacobs Institute is participating in a study designed to collect prospective clinical evidence to evaluate the approved use of the Pipeline™ Flex Embolization Device with Shield Technology™ for the endovascular treatment of adults (22 years of age or older) with wide-necked intracranial aneurysms

Detailed description

The Pipeline™ Flex Embolization Device with Shield Technology™ for the endovascular treatment of adults (22 years of age or older) with large or giant wide-necked intracranial aneurysms (IAs) in the internal carotid artery from the petrous to the superior hypophyseal segments. The Pipeline™ Flex Embolization Device with Shield Technology™ is also indicated for use in the internal carotid artery up to the terminus for the endovascular treatment of adults (22 years of age or older) with small and medium wide-necked (neck width ≥ 4 mm or dome-to-neck ratio \< 2) saccular or fusiform intracranial aneurysm (IAs) arising from a parent vessel with a diameter ≥ 2.0 mm and ≤ 5.0 mm.

Interventions

DEVICESHIELD

Pipeline SHIELD device under study

Sponsors

Jacobs institute
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Intervention model description

Surgical System Intervention

Eligibility

Sex/Gender
ALL
Age
22 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Adults (22 years of age or older) with large or giant wide-necked intracranial aneurysms (IAs) in the internal carotid artery from the petrous to the superior hypophyseal segments.

Design outcomes

Primary

MeasureTime frameDescription
Occurrence of thromboembolic event(s)12 MonthsThe Pipeline™ Flex Embolization Device with Shield Technology™ for the endovascular treatment of adults (22 years of age or older) with large or giant wide-necked intracranial aneurysms (IAs) in the internal carotid artery from the petrous to the superior hypophyseal segments. The Pipeline™ Flex Embolization Device with Shield Technology™ is also indicated for use in the internal carotid artery up to the terminus for the endovascular treatment of adults (22 years of age or older) with small and medium wide-necked (neck width ≥ 4 mm or dome-to-neck ratio \< 2) saccular or fusiform intracranial aneurysm (IAs) arising from a parent vessel with a diameter ≥ 2.0 mm and ≤ 5.0 mm.

Countries

United States

Contacts

CONTACTCarlos Pena, PhD, MS
cpena@jacobsinstitute.org2404810824

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Mar 11, 2026