Mechanical Ventilation, Positive End Expiratory Pressure (PEEP), Robotic Thoracic Surgery
Conditions
Keywords
robotic lung surgery, PEEP, capnothorax
Brief summary
The aim of this study is to assess the impact on lung mechanics during robotic lung resection when no capnothorax is used.
Detailed description
Assess the improvement of oxygenation, ventilation and lung mechanics in patients ventilated with individualized PEEP without capnothorax. PEEP requirement and lung mechanics without capnothorax will be compared with a historical cohort population of robotic surgery with capnothorax.
Interventions
None listed
Sponsors
Study design
Eligibility
Inclusion criteria
* Patients undergoing uniportal robotic lung resection under no capnothorax
Exclusion criteria
* Refusal to participate * Contraindications to recruitment maneuvers
Design outcomes
Primary
| Measure | Time frame | Description |
|---|---|---|
| Respiratory airway pressures | During intra-operative mechanical ventilation (4 hours) | Respiratory airway pressures (peak pressure, plateau pressure and PEEP in cmH2O) |
| Respiratory rate | During intra-operative mechanical ventilation (4 hours) | Respiratory rate (in cycles per minute) |
| Respiratory system compliance | During intra-operative mechanical ventilation (4 hours) | Respiratory pressures measurement will be combined to obtain respiratory system compliance. Respiratory system compliance = (plateau pressure-PEEP) / respiratory tidal volume (expressed in cmH2O/mL) |
Secondary
| Measure | Time frame | Description |
|---|---|---|
| Arterial blood gas parameters: sodium bicarbonate | During intra-operative mechanical ventilation (4 hours) | Arterial blood sample sodium bicarbonate concentration (in mmol/L) |
| Arterial blood gas parameters: pO2 | During intra-operative mechanical ventilation (4 hours) | pO2 in mmHg in arterial blood gas sample |
| Arterial blood gas parameters: base excess | During intra-operative mechanical ventilation (4 hours) | Base excess in arterial blood gas samples in mEq/L |
| Arterial blood gas parameters: pCO2 | During intra-operative mechanical ventilation (4 hours) | pCO2 in mmHg in arterial blood gas sample |
| Arterial blood gas parameters: pH | During intra-operative mechanical ventilation (4 hours) | pH of arterial blood gas samples (no unit can be applied) |
Countries
Spain