Quantification With Lutetium-177 on Cadmium-Zinc-Telluride Camera 3D

Quantification With Lutetium-177 on Cadmium-Zinc-Telluride Camera 3D

Status
Completed
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT06783088
Acronym
QUADO
Enrollment
20
Registered
2025-01-20
Start date
2025-03-10
Completion date
2025-05-12
Last updated
2025-12-23

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Prostate Cancer

Brief summary

The main of this study is to demonstrate the feasibility of carrying out quantitative acquisitions regardless of the energy peak considered (113 keV (kiloelectronVolts) or 208 keV or a combination of the 2 energy peaks). A study on phantom will optimise the reconstruction parameters. These parameters will then be applied to a population of patients who have already benefited from a recording on a 3D CZT camera (retrospective data).

Detailed description

Lutetium 177 is a beta emitter - and is used in therapy. It also emits during its radioactive decay, two gamma photons of energy 113 and 208 keV allowing to produce images. The dosimetry committee of the European Association for Nuclear Medicine (EANM) recommends using only the peak at 208 keV to obtain so-called quantitative images using a conventional camera also called an Anger camera. For several years, new semiconductor cameras (CZT cameras) have been available in nuclear medicine departments. They offer better performances particularly in terms of detection sensitivity and energy resolution. The nuclear medicine team has already carried out studies with Lutetium-177 with these semiconductor cameras on phantoms as well as dosimetry studies after treatment using Lutetium-177. This study should demonstrate the feasibility of carrying out quantitative acquisitions regardless of the energy peak considered (113 keV or 208 keV or a combination of the 2 energy peaks). A study on phantom will optimise the reconstruction parameters. These parameters will then be applied to a population of patients who have already benefited from a recording on a 3D CZT camera (Retrospective data).

Interventions

None listed

Sponsors

Central Hospital, Nancy, France
Lead SponsorOTHER

Study design

Observational model
OTHER
Time perspective
RETROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 99 Years
Healthy volunteers
No

Inclusion criteria

It is a retrospective study and the criteria to collect the imaging are: Inclusion Criteria: Patients treated by at least one cure of lutetium vipivotide tetraxetan with imaging

Exclusion criteria

Patient having sent an objection to the use of their data

Design outcomes

Primary

MeasureTime frameDescription
Demonstrate that the quantification of images obtained with the 113 keV peak is equivalent to the quantification obtained with the 208 keV peak.one dayMeasurement of contrast coefficients and metabolic volumes on reconstructed images

Countries