Skip to content

Safety and Effectiveness of the Orsiro Mission 48-mm Sirolimus Eluting Coronary Stent System in Subjects With Coronary Artery Lesions

A Prospective Multicenter Single Arm Study to Assess the Safety and Effectiveness of the Orsiro Mission 48-mm Sirolimus-Eluting Coronary Stent System for the Treatment of Subjects With Atherosclerotic Lesion(s)

Status
Recruiting
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06779630
Acronym
BIOFLOW-48
Enrollment
150
Registered
2025-01-16
Start date
2025-07-18
Completion date
2031-09-01
Last updated
2026-07-24

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Coronary Artery Disease

Keywords

Orsiro Mission, Sirolimus-Eluting, Coronary Stent System, coronary artery disease

Brief summary

The purpose of the study is to assess the safety and efficacy of the Orsiro® Mission 48- mm Sirolimus-Eluting Coronary Stent System in the treatment of subjects with atherosclerotic lesion(s) \>36 mm and ≤ 44 mm in length (by visual estimate) in the native coronary arteries with a reference vessel diameter of 2.25 mm to 4.0 mm. Patients enrolled in the United States will be followed for 2 years post index procedure with follow-up visits at 1, 6, 12 months and 2 years post index procedure. Patients enrolled outside of the United States will be followed through 5 years post index procedure with additional follow-up visits at 3 and 5 years post index procedure.

Interventions

DEVICEOrsiro Mission 48-mm Sirolimus-Eluting Coronary Stent System

Orsiro Mission is composed of a device (coronary stent system including a cobalt chromium stent platform) and a drug product (a formulation of sirolimus) contained in a bioabsorbable polymer coating.

Sponsors

Teleflex
Lead SponsorINDUSTRY
BIOTRONIK AG (A Teleflex Company)
CollaboratorUNKNOWN

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
TREATMENT
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

1. Subject is ≥ 18 years of age 2. Subject is able to understand the nature of the study and provide written informed consent. For sites outside of the United States: Note: For subjects presenting with STEMI and not in a position to read, interpret and sign the informed consent form, oral informed consent is required. 3. Subject is an acceptable candidate for percutaneous coronary intervention (PCI) according to the applicable guidelines. 4. Subject is an acceptable candidate for CABG. 5. Subject is eligible for dual antiplatelet therapy (DAPT) according to guidelines. 6. Subject has clinical evidence of ischemic heart disease, stable or unstable angina pectoris or documented silent ischemia. 7. Subject is willing and able to comply with study follow-up requirements. Angiographic inclusion criteria: 1. Subject has only one target lesion in a native coronary artery to be treated with the investigational device. Note: One additional non-target lesion may be treated with a non-investigational treatment (e.g. stent, balloon angioplasty, atherectomy) with the exception of brachytherapy, if it is located in a different coronary artery. The non-target lesion must be treated first and must be deemed an angiographic success. (Angiographic success is defined by a residual diameter stenosis \< 30% with TIMI 3 flow, as visually assessed by the physician, without the presence of prolonged chest pain or ECG changes consistent with MI.) Note: Multiple focal stenoses will be considered as a single lesion if they are amenable to treatment with a single study device. 2. Target lesion must be \> 36 mm and ≤ 44 mm in length by operator visual estimate and must be amenable to treatment with a single study device. 3. Target vessel must have a reference vessel diameter of 2.25-4.0 mm by operator visual estimate. 4. For sites in United States: Target lesion must be de novo or restenotic lesion in native coronary artery; restenotic lesion must have been treated with a standard PTCA only. For sites outside of the United States: Target lesion can be de novo, restenotic or in-stent restenotic, and must be located in a native coronary artery. 5. Target lesion must have angiographic evidence of ≥ 50% and \< 100% stenosis (by operator visual estimate which may be assisted by QCA / IVUS / OCT). Target lesion stenosis \< 70% should have clinical justification for treatment as per local standards. 6. Target vessel must have a Thrombolysis In Myocardial Infarction (TIMI) flow \> 1. For sites outside of the United States: Note: For STEMI, TIMI flow \> 1 prior to stent implantation (after opening the vessel with a guide wire or a balloon).

Exclusion criteria

1. For sites in United States only: Subject has clinical symptoms and/or electrocardiogram (ECG) changes consistent with acute ST elevation myocardial infarction (STEMI) within 72 hours prior to the index procedure. Note: Hemodynamically stable non-STEMI (NSTEMI) subjects are eligible for study enrollment. 2. Subject is hemodynamically unstable. 3. Subject is pregnant and/or breastfeeding or intends to become pregnant during the duration of the study. 4. Subject has a known allergy to contrast medium that cannot be adequately pre-medicated, or any known allergy to thienopyridine, aspirin, both heparin and bivalirudin, L-605 cobalt-chromium (Co-Cr) alloy or one of its major elements (cobalt, chromium, tungsten and nickel), acrylic, fluoropolymers, silicon carbide, PLLA or sirolimus. 5. Revascularization of any target vessel within 12 months prior to the index procedure or previous PCI of any non-target vessel within \<72 hours prior to the index procedure. 6. Future planned PCI (including staged procedure) or CABG after the index procedure. 7. Planned surgery or dental surgical procedure within 6 months of index procedure unless dual antiplatelet therapy can be maintained throughout the peri-surgical period. 8. History of a stroke or transient ischemic attack (TIA) within 6 months prior to the index procedure. 9. Subjects with active bleeding disorders, active coagulopathy, or any other reason, who are ineligible for DAPT. 10. Subject will refuse blood transfusions. 11. Subject has a left ventricular ejection fraction (LVEF) \< 30% within 6 months prior to or during the index procedure that was documented by any method. 12. Subject is dialysis dependent or has impaired renal function (i.e., serum creatinine \> 2.5 mg/dL or 221 µmol/L, determined within 7 days prior to the index procedure). 13. Subject has a documented white blood cell count \< 3,000 white blood cells/mm3 or a documented platelet count \< 100,000 platelets/mm3 or \> 700,000 platelets/mm3. 14. Subject is receiving oral or intravenous immunosuppressive therapy (inhaled steroids are permitted) or has known life-limiting immunosuppressive or autoimmune disease (e.g., human immunodeficiency virus, systemic lupus erythematosus; diabetes mellitus is permitted). 15. Subject is receiving or scheduled to receive chemotherapy within 30 days before or after the index procedure or has a malignancy that is not in remission. 16. Subjects under oral anticoagulation therapy (OAC) prior to index procedure unless DAPT + OAC (i.e. triple therapy) can be maintained according to guidelines. 17. Subject has life expectancy of \< 1 year. 18. Subject is currently participating or plans to participate in another clinical investigation with an investigational device or an investigational drug. 19. In the investigator's opinion, subject will not be able to comply with the follow-up requirements. Angiographic

Design outcomes

Primary

MeasureTime frameDescription
Target Lesion Failure (TLF) rate at 12 months post-index procedure12 monthsThe primary endpoint will be target lesion failure (TLF) rate at 12 months post-index procedure. TLF is defined as a composite of cardiac death, target vessel Q-wave or non-Q-wave myocardial infarction (TV-MI), or clinically driven target lesion revascularization (CD-TLR).

Secondary

MeasureTime frameDescription
Device successHospital Discharge (6-24 hours post-index procedure)Device success, defined as attainment of \< 30% residual stenosis of the target lesion (based on operator visual estimate) using the Orsiro Mission study stent only.
Procedure successHospital Discharge (6-24 hours post-index procedure)Procedure success, defined as attainment of \< 30% residual stenosis of the target lesion (based on operator visual estimate) using the Orsiro Mission study stent only without occurrence of in-hospital major adverse cardiac events (MACE).
All-cause death1, 6, 12 months and 2, 3, and 5 years post-index procedure
Any myocardial infarction (MI)1, 6, 12 months and 2, 3, and 5 years post-index procedure
Cardiac death or myocardial infarction (MI)1, 6, 12 months and 2, 3, and 5 years post-index procedure
Major cardiac adverse events (MACE) and individual MACE components1, 6, 12 months and 2, 3, and 5 years post-index procedureMACE is defined as a composite of all-cause death, Q-wave or non-Q-wave MI, and any clinically driven target lesion revascularization (TLR).
Target lesion failure (TLF) and individual TLF components1, 6, 12 months and 2, 3, and 5 years post-index procedureTLF is defined as a composite of cardiac death, target vessel Q-wave or non-Q-wave myocardial infarction (TV-MI), or clinically driven target lesion revascularization (CD-TLR).
Target vessel failure (TVF) and individual TVF components1, 6, 12 months and 2, 3, and 5 years post-index procedureTVF is defined as a composite of cardiac death, target vessel Q-wave or non-Q-wave myocardial infarction (TV-MI), and clinically driven target vessel revascularization (CD-TVR).
Target lesion revascularization (TLR)1, 6, 12 months and 2, 3, and 5 years post-index procedure
Target vessel revascularization (TVR)1, 6, 12 months and 2, 3, and 5 years post-index procedure
Stent thrombosis1, 6, 12 months and 2, 3, and 5 years post-index procedureStent thrombosis will be assessed according to Academic Research Consortium - 2 (ARC-2) definitions.

Countries

Austria, France, Germany, Poland, Switzerland, United States

Contacts

CONTACTBIOFLOW-48 Project Manager
bioflow-48@teleflex.com1-866-246-6990

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Jul 25, 2026