Brief summary

The goal of this trial is to investigate the prognostic value of monitoring finger blood pressures (FBPs) in predicting the success of surgically created arteriovenous fistula (AVF) for patients with end stage renal disease. The main questions it aims to answer is: \- Can FBPs predict AVF maturation? Participants will undergo FBP measurements at pre-op, immediately post-op, 4 weeks and 6 weeks post-AVF creation.

Interventions

OTHERFinger Blood Pressure Measurement

Finger Blood Pressure Measurement were taken from three digits: the thumb (F1), the middle finger (F2), and the little finger (F3) from both arms.

Sponsors

Singapore General Hospital
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
21 Years to 90 Years
Healthy volunteers
No

Inclusion criteria

* Participants has documented Chronic Kidney Disease (CKD), determined by Glomerular Filtration Rate (GFR) * Participant is recommended for renal replacement therapy based on clinical assessment of renal function as well as CKD staging, as documented in clinical notes. * Haemodialysis was chosen as the most appropriate renal replacement therapy * Participant is able to consent to the creation of an AVF in preparation for hemodialysis. * Participant is able to adhere to follow-up assessments of AVF maturation, if applicable.

Exclusion criteria

* Subject had a previous AVF and is now undergoing surgery for another AVF creation * Subject has amputation distal to AVF * Subject is pregnant or planning to conceive * Participants is unable to consent

Design outcomes

Primary

MeasureTime frameDescription
Correlation between AVF maturation and changes in Finger Blood Pressure measurements at baseline and immediately post-opWithin 24 hoursTo determine whether if there are any pattern in changes observed in FBP pre and post-creation that can be used for correlation to AVF maturation.

Secondary

MeasureTime frameDescription
Correlation between AVF maturation and changes in Finger Blood Pressure measurements across other timepointsUntil 6 weeks post-operationTo determine whether changes in FBP across time points (pre-op, post-op, 4 weeks and 6 weeks post-op) is correlated with AVF maturation

Countries

Singapore

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026