Electrocardiographic and Electrophysiologic Changes After Percutaneous Closure of Atrial Septal Defect

Electrocardiographic and Electrophysiologic Changes After Percutaneous Closure of Atrial Septal Defect

Status
Not yet recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06761807
Enrollment
65
Registered
2025-01-07
Start date
2025-01-20
Completion date
2027-11-02
Last updated
2025-01-07

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

ASD, Brady Arrythmia

Keywords

ASD, EPD, Brady arrythmia

Brief summary

Primary outcomes : Determining the incidence of SAN and AVN dysfunction before and after percutaneous ASD closure Comparing ECG and EP parameters of SAN and AVN before and after percutaneous ASD closure Secondary outcomes : Assessing clinical, echocardiographic and procedural risk factors affecting the AVN function after ASD closure device implantation Determining the incidence of supraventricular arrhythmia inducibility before and after percutaneous ASD closure

Detailed description

Atrial septal defects (ASDs) are one of the most common types of acyanotic congenital heart diseases, comprising 6-10% all congenital heart defects. They represent the most common congenital heart disease diagnosed during adulthood. Secundum ASD is a defect in the fossa ovalis (septum primum), or the superior limb of the septum secundum and is the most common type of ASD (80% of all ASDs). ASD closure for secundum ASD is recommended regardless of symptoms in patients with evidence of right ventricular (RV) volume overload and no pulmonary arterial hypertension (PAH) or left ventricular (LV) disease. Percutaneous device closure has become the first choice for secundum defect closure in presence of a feasible morphology with a reported low risk of serious complications (≤1% of patients). Subclinical electrocardiography (ECG) abnormalities, sinoatrial node (SAN) and atrioventricular node (AVN) conduction abnormalities have been reported in patients with ASDs. . The reported incidence of AVN block following ASD device closure varies widely from none up to 6.1%. High-grade AVN block after device closure typically occurs in the first 24-hour post-procedure and may mandates device removal for resolution of heart block. The mechanism of AVN block after ASD device occlusion could be due to mechanical pressure on the AV node or edema related to trauma. Young age and large defect/device size may be a risk factor for AVN block. Deficient rims of the ASD may also have an impact on development of AVN block. Whether or not there is a direct impact of ASD device closure on the functional properties of AVN and SAN is not well elucidated. Testing the electrocardiographic and electrophysiologic (EP) parameters of AVN and SAN before and after the procedure could obviously help understanding the real risk

Interventions

PROCEDUREElectrophysiology study of heart

The procedure will be done comparatively for each patient; before the device placement and immediately after the procedure. This will be done approaching the same sheath that is placed for ASD device closure (the right femoral vein). Only one quadripolar EP catheter will be used, it will be placed in high right atrium then at His bundle. The EP study will include: Assessment of SAN function using cSNRT (through HRA pacing) Assessment of AH and HV intervals (through His bundle EGM) Assessment of antegrade AVN RP (refractory period) and AVN WP (Wenckebach point) through extra-stimuli and incremental atrial pacing. Any inducible arrhythmia will be reported

Sponsors

Assiut University
Lead SponsorOTHER

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
DIAGNOSTIC
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* All patients presented with secundum ASD eligible for percutaneous transcatheter ASD closure at Assiut university heart hospital

Exclusion criteria

* No exclusion

Design outcomes

Primary

MeasureTime frameDescription
incidence of SAN dysfunctionbaselineDetermining the incidence of SAN and AVN dysfunction before and after percutaneous ASD closure Comparing ECG and EP parameters of SAN and AVN before and after percutaneous ASD closure
incidence of AVN dysfunctionbaselineincidence of AVN dysfunction before and after percutaneous ASD closure

Contacts

Primary ContactFatma Osama, Master student
fatmaosama748130@gmail.com01032772709