Skip to content

Mpact 3D Metal Monolit Study

Prospective, Multicentre, Non-randomised, Open Study Evaluating the Efficacy and Fixation of the Mpact 3D Metal Monolit Cup

Status
Recruiting
Phases
Unknown
Study type
Observational
Source
ClinicalTrials.gov
Registry ID
NCT06748885
Enrollment
88
Registered
2024-12-27
Start date
2024-02-28
Completion date
2030-12-31
Last updated
2024-12-27

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Total Hip Arthroplasty (THA)

Brief summary

Total hip arthroplasty (THA) is one of the most common operations performed in orthopaedics to improve a patient's quality of life. Surgeons are constantly seeking to improve all aspects of care related to this procedure, whether it be improving implant technology, improving instrumentation or the technique involved in performing the procedure. In recent years, a new porous titanium coating has been introduced to promote good osseointegration of uncemented cups. High friction torque and a feeling of immediate anchorage provide excellent primary stability, while high porosity ensures bone growth providing secondary stability. With higher porosity than standard coatings, a greater volume of bone can be present in the porous surface, giving a proportional increase in force at the interface. he Mpact 3D Metal Monolith cup has been designed to provide greater range of motion and improved joint stability, with a reduced risk of dislocation. It is an innovative design that improves stability and provides a favourable environment for long-term biological metal-bone fixation. The current study aims to collect clinical and radiological data to assess the function of the operated hip and the stability of the Mpact 3D Metal Monolith cup at 2 years and survival at 5 years for the treatment of patients requiring hip arthroplasty.

Interventions

DEVICEMpact 3D Metal Monolith

THA with Mpact 3D Metal Monolith

Sponsors

Medacta International SA
Lead SponsorINDUSTRY

Study design

Observational model
COHORT
Time perspective
PROSPECTIVE

Eligibility

Sex/Gender
ALL
Age
18 Years to 75 Years
Healthy volunteers
No

Inclusion criteria

1. Patient with a disease that corresponds to the indications for use of Medacta implants (according to the instructions for use) 2. Patient eligible for primary total hip arthroplasty 3. Patient aged between 18 and 75 years 4. Patient covered by the French Social Security system or an equivalent protection scheme. 5. Patient able, in the investigator's opinion, to comply with the requirements of the study.

Exclusion criteria

1. Patient suffering from inflammatory arthritis 2. Previously operated hip 3. Patient requiring a transplant 4. Hip tumour involved 5. Patient with progressive local or systemic infection 6. Severe acetabular dysplasia 7. Patient with muscle loss, neuromuscular disease or vascular impairment of the affected limb. 4\. Patient with known medical problems that may compromise independent recovery of mobility 5. Patient with a BMI greater than 40 kg/m². 6. Patient with major cognitive impairment that prevents him/her from fully understanding the requirements of the study 7. Patient living in a geographical area where study follow-up is not possible. 8. Patient taking part in interventional research 9. Minor patient 10. Protected adult patient 11. Vulnerable person according to article L1121-6 of the Public Health Code

Design outcomes

Primary

MeasureTime frameDescription
Evaluation of the hip functionPreoperative, 3 months, 6 months, 1 year, 2 years, 5 yearsThe Harris Hip Scale (HHS) was developed for the assessment of the results of hip surgery, and is intended to evaluate various hip disabilities and methods of treatment in an adult population. The original version was published 1969\[1\]. The HHS is an outcome measure administered by a qualified health care professional, such as a physician or a physical therapist. The HHS is a measure of dysfunction so the higher the score, the better the outcome for the individual. Results can be recorded and calculated online. The maximum score possible is 100. Results can be interpreted with the following: \<70 = poor result; 70-80 = fair, 80-90 = good, and 90-100 = excellent.

Secondary

MeasureTime frameDescription
Analysis of the wear of the polyethylene insert (HighCross) at 2 years2 yearsMartell method of linear wear measurement
Evaluation of the fixation and osteolysisImmediate postoperative, 3 months, 6 months, 1 year, 2 years, 5 yearsRadiological analysis
Analysis of the primary stability of the implant at 2 years2 yearsProtocol EBRA-Cup: Measurement of longitudinal/transversal migration of acetabular cup in digital serial radiographs (minimum of 4 x-rays per series). Full size AP pelvis radiographs are required. Accuracy: +/- 1mm.
Evaluation of the safety of the implantIntraoperative, immediate postoperative, 3 months, 6 months, 1 year, 2 years, 5 yearsCollection of intraoperative and postoperative complications
Evaluation of the survival of the implant3 months, 6 months, 1 year, 2 years, 5 yearsKaplan-Meier survival method
Evaluation of the mobilityPreoperative, 3 months, 6 months, 1 year, 2 years, 5 yearsThe Oxford Hip Score (OHS) is a joint-specific, patient-reported outcome measure designed to assess disability in patients undergoing total hip replacement. The OHS is a short 12-item survey that can be done with pen and paper. Patients are asked to reflect on their pain and functional ability over the previous four weeks. There are two domains (pain and function) with six items or questions in each. Each item has five possible responses. In the original scoring responses were from 1 = least difficult to 5= most difficult. Item scores are summed to give a total score from anywhere between 12 and 60. The lower the score, the better the outcome.

Countries

France

Contacts

Primary ContactPhilippe Anract
philippe.anract@aphp.fr01 58 41 30 38

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026