Skip to content

Echo Acquisition Despite Geographic Separation by Replication of Human Movements (EAGER)

Echocardiographic Acquisition With Geographic Separation of Patients and Sonographers With Roboot Assistance (EAGER)

Status
Not yet recruiting
Phases
NA
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06742905
Acronym
EAGER
Enrollment
50
Registered
2024-12-19
Start date
2025-01-15
Completion date
2025-12-31
Last updated
2024-12-19

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Echocardiography

Keywords

Echocardiography

Brief summary

Echocardiography is a cornerstone of modern cardiology management, but access in rural and remote areas is limited. We have developed a robot (Edler named after the originator of echocardiography) which enables a sonographer to complete an examination at a distance. This study seeks to compare the images obtained by both methods, the completeness of the exam over a feasible time, and to identify particular components of the exam that are difficult to obtain using the robot.

Detailed description

The EAGER study is an effectiveness and feasibility trial of robot -assisted echo. Patients who have undergone a standard echo will be asked to have a repeat study with a different sonographer, working remotely, obtaining images using the robot. This study is limited to 1 hour and as many views as possible will be obtained. During the study, the remote sonographer and patient are in direct contact over a video link. Another person will be in the room with the patient and the patient will be instructed on the use of a stop switch which will disengage the robot if they feel uncomfortable. The acquired images will be saved to the imaging cloud and interpreted by an imaging specialist blinded to the original echocardiogram. A side-by-side comparison will be undertaken for each view, and image quality and study completeness will be assessed.

Interventions

DIAGNOSTIC_TESTRobot-guided echo

This echo will be performed by a remote sonographer, though a robot

DIAGNOSTIC_TESTStandard echocardiogram

Echocardiogram acquired by a sonographer at the patient's bedside

Sponsors

Baker Heart and Diabetes Institute
Lead SponsorOTHER

Study design

Allocation
NON_RANDOMIZED
Intervention model
SEQUENTIAL
Primary purpose
DIAGNOSTIC
Masking
SINGLE (Investigator)

Eligibility

Sex/Gender
ALL
Healthy volunteers
No

Inclusion criteria

* Having a conventional echocardiogram

Exclusion criteria

* Declined consent to undergo both examinations

Design outcomes

Primary

MeasureTime frameDescription
Proportion complete1 hourProportion of a standard acquisition protocol obtainable using robotic acquisition over 1 hour

Secondary

MeasureTime frameDescription
Proportion complete1 hourProportion of echo views with the same information provided by conventional echo
Proportion diagnostic features correctly identified by robotic echo1 hourProportion diagnostic features correctly identified by robotic echo

Countries

Australia

Contacts

Primary ContactThomas H Marwick, MBBS, PhD, MPH
tom.marwick@baker.edu.au0385321550

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: Feb 4, 2026