Skip to content

Comparison of Speech Understanding Between Tonotopy-based Fitting and Setting Based on Evolutionary Algorithms

Comparison of Speech Understanding Between Tonotopy-based Fitting and Evolutionary Algorithm-based Setting: a Prospective Cross-sectional Study

Status
Recruiting
Phases
Unknown
Study type
Interventional
Source
ClinicalTrials.gov
Registry ID
NCT06737185
Enrollment
22
Registered
2024-12-17
Start date
2025-01-15
Completion date
2028-01-15
Last updated
2026-05-06

For informational purposes only — not medical advice. Sourced from public registries and may not reflect the latest updates. Terms

Conditions

Sensorineural Hearing Loss, Bilateral

Keywords

cochlear implant, evolutionary algorithms, tonotopy-based fitting

Brief summary

Main objective: Compare speech recognition in noise with tonotopic setting (FS4T) and with tonotopic fitting modified by evolutionary algorithm (EAFS4T) in adult patients implanted for 6 months or more with a MED-EL cochlear implant with FS4T. Secondary objectives: Comparison of FS4T and EAFS4T settings * for speech recognition in quiet * for subjective auditory spatial perception * for subjective auditory and musical perception

Detailed description

Introduction: Cochlear implantation allows the rehabilitation of profound bilateral deafness, restoring speech perception and verbal communication when the traditional hearing aid no longer provides satisfactory hearing gain. A cochlear implant includes an electrode array and its functioning is based on the principle of cochlear tonotopy: each electrode encodes a frequency spectrum according to its position in the cochlea (high frequencies are assigned to the basal electrodes and low frequencies to the apical electrodes). The cochlear implant thus breaks down the frequency spectrum into a number of frequency bands via bandpass filters corresponding to the number of electrodes in the implant. During the fitting these bands can be modified by the audiologist. The fitting software developed by the manufacturers proposed a default fitting with a lower limit between 100 and 250 Hz according to the brands and an upper limit of about 8500 Hz. The frequency bands assigned to each electrode follow a logarithmic scale with the high frequencies for the basal electrodes and the low frequencies for the apical electrodes. This distribution takes into account the number of active electrodes but does not take into account the anatomy and the natural cochlear tonotopy specific to each patient. Several studies have analyzed the anatomical variations of the cochlear dimensions: size of the cochlea and the ratio between the contact surfaces of the electrodes with the cochlea are variable from one patient to another. The insertion depth during surgery is also variable due to parameters related to the patients as well as to the operator, which seems to impact the understanding of speech in noise. Mathematical algorithms have recently been developed to estimate the cochlear tonotopy of each patient from a CT scan assessment. CT imaging of the implanted ear combined with 3D reconstruction software, provides cochlear length measurements Using this approach it is possible to measure the position of each electrode relative to the cochlear apex. Recently, MED-EL (Austria) has developed a new approach based on CT-scan and tuning of the frequencies associated with each electrode using anatomical information of position of the electrodes in the cochlea: this fitting is called anatomy-based fitting. A tonotopy-based fitting allows for better results in pitch perception or speech perception in noise or musical perception. However, there is a large variability in the results observed between patients. This variability could be due to the individual characteristics of the listeners (neuronal survival, current propagation and spread, duration of deafness, lack of cortical plasticity). A modification of frequency allocations in the setting could take into account this individual variability and improve speech discrimination and music perception. Saadoun et al. (2022) studied on 27 subjects the effect of an adjustment of frequency allocation by an evolutionary algorithm (EA) approach and showed an improvement in speech perception in noise compared to a default setting (not based on tonotopy) for patients implanted for more than 6 months in a bimodal situation (with a contralateral prosthesis). We therefore propose to use evolutionary algorithms to modify the tonotopy-based fitting and improve the perception in noise of implanted patients. Main objective: Compare speech recognition in noise with tonotopic setting (FS4T) and tonotopic fitting modified by evolutionary algorithm (EAFS4T) in adult patients implanted for 6 months or more with a MED-EL cochlear implant with FS4T. Secondary objectives: Comparison of FS4T and EAFS4T settings * for speech recognition in quiet * for subjective auditory spatial perception * for subjective auditory and musical perception Plan of the study: It is a prospective open monocentric transversal study.

Interventions

OTHEREAFS4T: modification with evolutionary algorithm of tonotopic-based fitting

Comparison of FS4T and EAFS4T

Sponsors

MED-EL Elektromedizinische Geräte GesmbH
Lead SponsorINDUSTRY

Study design

Allocation
NA
Intervention model
SINGLE_GROUP
Primary purpose
OTHER
Masking
NONE

Eligibility

Sex/Gender
ALL
Age
18 Years to No maximum
Healthy volunteers
No

Inclusion criteria

* Adult patient (\>= 18 years old) speaking French * Patient who fulfils the criteria for cochlear implantation

Exclusion criteria

* retro-cochlear pathology: auditory neuropathy, vestibular schwannoma

Design outcomes

Primary

MeasureTime frameDescription
Speech recognition in noise6 weeks after EAFS4T fittingHINT-5 min test. Noise level: 60 dB SPL. Speech level: adaptive with the answers of the participant. Result: speech-to-noise ratio (speech reception threshold, SRT50) for 50% of intelligibility in noise. Test with EAFS4T and with FS4T.

Secondary

MeasureTime frameDescription
Speech recognition in quiet6 weeks after EAFS4T fittingOne list of 10 disyllabic words (Fournier lists) at 65 dB SPL. The participant has to repeat the word emitted. Result: score on 10. Test with EAFS4T and with FS4T
Subjective auditory spatial perceptionat EAFS4T fitting (6 months after cochlear implant activation) and 6 weeks after EAFS4T fittingSSQi15 questionnaire (" Speech, Spatial, and Qualities of hearing scale ", SSQ). The questionnaire consists of 15 questions describing various real-world hearing situations. The subject answers each question with a score on a visual analogue scale graduated from 0 to 10 ranging from "not at all" to "yes perfectly". The result obtained is composed of * a total average score equal to the sum of the scores of all the questions divided by the total number of questions. * 3 average sub-scores describing 3 subscales: Speech hearing with 5 questions, Spatial hearing with 5 questions, Quality of hearing with 5 questions. Questionnaire with FS4T (at EAFS4T fitting) and with EAFS4T (6 weeks after EAFS4T fitting)
Subjective assessment of auditory perceptionat EAFS4T fitting (6 months after cochlear implant activation) and 6 weeks after EAFS4T fittingAssessment of sound quality in silence and in noise with 4 statements. Likert scale from 1 to 5. Score on 20. Likert scale with FS4T (at EAFS4T fitting) and with EAFS4T (6 weeks after EAFS4T fitting)
Subjective assessment of musical perceptionat EAFS4T fitting (6 months after cochlear implant activation) and 6 weeks after EAFS4T fittingSix questions from the Munich Music Self-Questionnaire \[Stark et al. 2003\]. Questionnaire with FS4T (at EAFS4T fitting) and with EAFS4T (6 weeks after EAFS4T fitting)

Countries

France

Contacts

CONTACTVincent Péan, PhD
vincent.pean@medel.com603592974
PRINCIPAL_INVESTIGATORAlexis BOZORG GRAYELI, Pr

Centre Hospitalier Universitaire Dijon

Outcome results

None listed

Source: ClinicalTrials.gov · Data processed: May 7, 2026